Process transmitters
12Pages

{{requestButtons}}

Catalog excerpts

Process transmitters - 1

Process transmitters Electronic pressure measurement IwikaII ^ Part of your business

Open the catalog to page 1
Process transmitters - 2

Versatile in application Process transmitters are suitable for many industrial measuring requirements in the widest variety of applications. They monitor pumps, detect the level in The measured value can be read on site as well as being transmitted to a process control system, a controller or a terminal. The data transmission is achieved using an analogue 4 ... 20 mA signal or via a bus protocol. With the HART®, PROFIBUS® PA or FOUNDATION™ Fieldbus bus systems, there is the possibility to transmit further information from the process and/or measuring instrument, in addition to the primary...

Open the catalog to page 2
Process transmitters - 3

Process transmitters from WIKA High flexibility Special features ■■ High measuring accuracy ■■ Freely scalable measuring ranges ■■ Wetted parts from stainless steel or special materials ■■ Different hazardous area approvals ■■ Large variety of case variants ■■ 4 ... 20 mA, 4 ... 20 mA HART® or bus signals The transmitters can be fitted in a wide number of ways. The ability for the position of the display heads to be adjusted in relation to the process connection and the possibility of ‘snapping’ the display into one of four directions makes its mounting easier and guarantees the readability...

Open the catalog to page 3
Process transmitters - 4

ATEX 2017 X *o£Ce* tun""L o» ^15*'» lie '4 1576 -^ UPT-20 with display and G 1/2 B process connection Wide range of applications This measuring instrument is as suited to machine building and plant construction as it is for the traditional areas for process transmitters. The UPT also finds its place in chemical plants, especially in the Ex ia version (intrinsically safe design). With flush process connections, the requirements of the hygienic, pharmaceutical and food industries are fulfilled. The instrument is available with analogue output signal or with HART® protocol to the latest HART®...

Open the catalog to page 4
Process transmitters - 5

Universal process transmitters Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Specifications Measuring ranges: Absolute pressure 0 … 0.4 bar to 0 … 40 bar Relative pressure 0 … 0.4 bar to 0 … 1,000 bar (600 bar for UPT-21) Vacuum ranges −0.2 … +0.2 bar to −1 … +40 bar Output signals: 4 … 20 mA 4 … 20 mA with HART® signal Measuring accuracy: 0.15 % (standard) 0.1 % 0.2 % Turndown: up to 5:1, if the data sheet specifications are maintained recommended up to 20:1 with restricted accuracy Communication: DD, EDD, DTM* in download area on www.wika.com Wetted parts: Stainless...

Open the catalog to page 5
Process transmitters - 6

IPT-11 with flange connection and electropolished stainless steel case IPT-10 with aluminium double chamber case Large variety of cases The IPT industrial process transmitter is available in seven case variants. The choice of case materials is between plastic, aluminium and stainless steel. In particular, the requirements on explosion-proof cases for explosion protection is catered for here with two case variants (aluminium and stainless steel castings). Plastic, single or double chamber Aluminium, single or double chamber case Electropolished stainless steel Cast stainless steel, single or...

Open the catalog to page 6
Process transmitters - 7

Industrial process transmitters Model IPT-10, with pressure port Model IPT-11, with flush diaphragm Specifications Measuring ranges: Absolute pressure 0 … 0.1 bar to 0 … 60 bar Relative pressure 0 … 0.1 bar to 0 … 4,000 bar (600 bar for IPT-11) Vacuum ranges −0.05 … +0.05 bar to −1 … +60 bar Output signals: 4 … 20 mA 4 … 20 mA with HART® signal FOUNDATION™ Fieldbus PROFIBUS® PA Measuring accuracy: 0.075 % with ceramic measuring cell 0.1 % with metallic measuring cell Turndown: up to 5:1, if the data sheet specifications are maintained recommended up to 30:1 with restricted accuracy Process...

Open the catalog to page 7
Process transmitters - 8

DPT-10 with electropolished stainless steel case and two 990.27 flange diaphragm seals assembled via capillaries DPT-10 with aluminium double chamber case in Ex d design While the models UPT and IPT can be used for relative and absolute pressure measurements, the model DPT-10 is available for differential pressure measurements. Typical applications are pump and filter monitoring and also level and flow measurement. Level measurement A common application is the monitoring of a closed vessel, in which the overlying gas phase must be subtracted from the hydrostatic pressure of the vessel...

Open the catalog to page 8
Process transmitters - 9

Differential pressure transmitter Specifications Measuring ranges: Differential pressure 0 ... 0.01 bar to 0 … 40 bar Maximum working pressure (static pressure): Overload on one side 160 bar or 420 bar Overload on both sides 240 bar or 630 bar Output signals: 4 … 20 mA 4 … 20 mA with HART® signal FOUNDATION™ Fieldbus PROFIBUS® PA Measuring accuracy: 0.075 % with measuring ranges > 0.03 bar 0.15 % with measuring ranges ≤ 0.03 bar Turndown: up to 5:1, if the data sheet specifications are maintained recommended up to 30:1 with restricted accuracy Process connection: 1/4-18 NPT per IEC61518...

Open the catalog to page 9
Process transmitters - 10

Communication with process transmitters Fieldbus systems in process control technology Process Control Systems (PCS) are observing units that fully monitor, manage and control industrial plants (for example). All parameters and measured data related to the process are transmitted to a central point and evaluated according to a defined algorithm. A purely analogue output signal only enables the communication from the measuring instrument for control. With process transmitters with fieldbus interfaces, further possibilities are offered. The digital bus signal, or also the HART® protocol,...

Open the catalog to page 10
Process transmitters - 11

DTMs (Device Type Managers) Alongside the primary value (PV), the digital bus instruments also enable further values to be passed on to the instruments that relate to the same data loop. This therefore offers the possibility, for example, to react to a rising temperature value in a sensor. Likewise, the instrument can output already calculated values such as level in units of length and volume in litres (for example). This requires a continuous input of process data and the possibility to be able to change the instrument parameters easily. Such possibilities are offered by DTMs (Device Type...

Open the catalog to page 11

All WIKA Alexander Wiegand SE & Co. KG catalogs and technical brochures

  1. FSD-3

    4 Pages

  2. A-10

    12 Pages

  3. 990.10

    6 Pages

  4. SC58

    3 Pages

  5. CS4R

    5 Pages

  6. CPG500

    6 Pages

  7. CPG1500

    11 Pages

  8. PM 01.15

    2 Pages

  9. BWX

    5 Pages

  10. BA, BAX

    5 Pages

  11. A2G-40

    3 Pages