Pressure | Temperature | Level Industrial steam and hot-water boiler systems
Open the catalog to page 1About us As a family-run business acting globally, with 10,200 highly qualified employees, the WIKA group of companies is a worldwide leader in pressure and temperature measurement. The company also sets the standard in the measurement of level, force and flow, and in calibration technology. Founded in 1946, WIKA is today a strong and reliable partner for all the requirements of industrial measurement technology, thanks to a broad portfolio of high-precision instruments and comprehensive services. With manufacturing locations around the globe, WIKA ensures flexibility and the highest delivery...
Open the catalog to page 2WIKA – Your partner for industrial steam and hot-water boiler systems Industrial boiler systems are used in the food and automotive industries as well as in hospitals and many other areas. In them, a whole series of modules work hand in hand: for example boilers, economisers, oil pressure control, water treatment and return flow temperature safeguard. The goal is the efficient provision of energy in the form of hot water or steam. As a manufacturer of industrial steam and hot-water boiler systems, you know how important it is to be able to rely on every single component, one hundred percent....
Open the catalog to page 3The majority of industrial boiler manufacturers offer additional modules that improve the efficiency, the performance and the service life of an industrial boiler. For steam boilers, one of these important modules is the economiser. Whether it is mounted and integrated directly on the boiler or if it is assembled independently as a standalone module on-site later: The principle of the economiser is that it uses the extracted heat from the flue gas to preheat the feedwater. In this way the economiser improves the boiler efficiency in an ecological and environmental way as in addition, substantial...
Open the catalog to page 4Temperature Bourdon tube pressure gauge 113.53,100 211.11 212.20 213.53, 23x.50.1x0 Pressure switch PCS, PXS Glass level gauge LGG-E Threaded thermo meter TF37 Expansion thermo meter SB15, SW15
Open the catalog to page 5Industrial burner The choice of a burner is essential while acquiring an industrial steam or a hot-water boiler. The energy source (fuel or gas), the burner power, the end user application and finally the choice of the burner manufacturer will be the determining criteria of the selection of the burner model. Reliability, energy efficiency, noise emissions and ease of use are further key buying factors that will decide an end user to adopt one specific burner model. The settings of the combustion system are decisive for economical operation and a long service life of the boiler. Burner manufacturers...
Open the catalog to page 6Temperature Bourdon tube pressure gauge 213.53 23x.50 Capsule pressure gauge 612.20 Resistance thermo meter TR10 TR31 Threaded thermo meter TF35 TF37 TFT35 Expansion thermo meter with switch contact SB15 Expansion thermo meter IFC
Open the catalog to page 7The correct function of the boiler can be maintained by using a degassing system. The degassing will prevent the plant (especially the pipelines, the economiser, the feedwater vessel and the boiler itself) from any corrosion coming from the feedwater. It will limit the oxidisation and keep a low level of oxygen and carbon dioxide in the water and steam circuit. For this specific process, different temperature, pressure and level measurements and controls are made. A low and higher pressure will be measuremed and controlled through a pressure gauge and a pressure transmitter, the temperature level...
Open the catalog to page 8Temperature Bourdon tube pressure gauge 111.1x 213.53 23x.50 Pressure gauge with output signal PGT23 Bypass level indicator BNA Threaded thermo meter TF35 TF37 TFT35
Open the catalog to page 9Pressure booster system An industrial steam boiler is a complex heating device on which are mounted different types of components that generally work under extreme conditions. Depending on the needs and the application of the end user, additional integrated or stand-alone modules, such as economisers, reverse osmosis systems, superheaters, etc., can be added to the steam boiler system in order to substantially increase and optimise the boiler efficiency. A module that can be added and integrated into the boiler system is the pressure booster system. Its role is to feed the steam boiler with a...
Open the catalog to page 10Bourdon tube pressure gauge 113.53 213.53 23x.50 Pressure switch PSM02 Pressure switch, maximum pressure limiter PSM-520
Open the catalog to page 11On industrial steam boilers, the use of an additional water treatment module, a reverse osmosis system, is generally required. The aim of the reverse osmosis system is to remove minerals from the feedwater and eliminate deposits inside or outside the boiler tubes, as far as possible, as they affect the efficiency and the performance of the steam production. For the measurement of the water pressure during the filtering into the diaphragm system, robust and precise pressure measuring instruments are needed as vibration may occur during the process. WIKA’s product range for pressure measurement...
Open the catalog to page 12Bourdon tube pressure gauge 111.1x 113.53 213.53 23x.50 Pressure gauge with switch contacts PGS23 Pressure measuring system PME01 PMM01
Open the catalog to page 13Accessories Pressure gauge stopcock/Pressure gauge cock 910.10 Instrument mounting brackets 910.16 Shut-off valve for pressure gauges 910.11 Pressure gauge in-line filters 910.22 Needle valve and multiport valve IV10, IV11 Snubber for pressure measuring instruments 910.12 Cooling element for pressure measuring instruments 910.32 Settable overpressure protector 910.13 Adhesive label set for red and green circular arcs 910.33 Precision digital pressure gauge CPG1500 “myWIKA device” app Play Store Syphons and connecting pipes 910.15 Calibration service Consultation, design, implementation � all...
Open the catalog to page 14Manufacturer-independent calibration - fast and precise for ... Pressure ■ C alibration using working standards (precise electrical pressure measuring instruments) or high-accuracy reference standards (pressure balances) ■ With an accuracy down to 0.003 % of reading for the standard used ■ In accordance with the directives DIN EN 837, DKD-R 6-1 or EURAMET cg-3 ■ C omparative calibration in calibration baths with an accuracy down to 10 mK ■ Comparative calibration in tube furnaces with an accuracy down to 100 mK Current, voltage and resistance ■ DC current from 0 mA ... 100 mA ■ DC voltage from...
Open the catalog to page 154 Pages
120 Pages