Catalog excerpts
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications ■■ Machine building ■■ Shipbuilding ■■ Measurement and control technology ■■ Hydraulics and pneumatics ■■ Pumps and compressors Special features ■■ Measuring ranges from 0 ... 0.05 to 0 ... 1,000 bar ■■ Non-linearity 0.25 % or 0.5 % ■■ Output 4 ... 20 mA, DC 0 ... 10 V, DC 0 ... 5 V and others ■■ Electrical connection: Angular connector form A and C, circular connector M12 x 1, cable outlet 2 m Pressure transmitter, model A-10 Description The model A-10 pressure transmitter for general industrial applications is not only notable for its compact design, but it also offers excellent quality at an extremely competitive price. The user can choose between a non-linearity of 0.25 % and 0.5 %. A free test protocol provides information on the measuring points recorded during manufacture. The model A-10 is set up for worldwide use through the international cULus and EAC certification. The various pressure units and process connections required for particular operating conditions are available at short notice. WIKA data sheet PE 81.60 ∙ 08/2017 Data sheets showing similar products: High-quality pressure transmitter for general industrial applications; model S-
Open the catalog to page 1Gauge pressure WIKA data sheet PE 81.60 • 08/2017
Open the catalog to page 2Vacuum and +/- measuring range 1 ) If the medium water is measured, a higher overload safety is recommended. The given measuring ranges are also available in mbar, kg/cm2, MPa and kPa. Other measuring ranges available on request. 3-fold overload safety available on request. Vacuum tightness Yes (for restrictions see overload safety) WIKA data sheet PE 81.60 • 08/2017
Open the catalog to page 31) Not possible with non-linearity 0.25 % BFSL 2) Only possible for temperatures up to 80 °C (176 °F) 3) Not possible with measuring ranges < 0.1 bar (or equivalent) The power supply for the pressure transmitter must be made via an energy-limited electrical circuit in accordance with section 9.3 of UL/EN/IEC 61010-1, or an LPS per UL/EN/IEC 60950-1, or class 2 in accordance with UL1310/UL1585 (NEC or CEC). The power supply must be suitable for operation above 2,000 m should the pressure transmitter be used at this altitude. Total current consumption Current (2-wire): Signal current, max....
Open the catalog to page 4Optionally the model A-10 is available with an improved non-linearity. Depending on the selected non-linearity the following values result:
Open the catalog to page 5Time response Measuring range Reference conditions (per IEC 61298-1) Temperature 15 ... 25 °C (59 ... 77 °F) Atmospheric pressure 860 ... 1,060 mbar (12.5 ... 15.4 psi) Operating conditionsIngress protection (per IEC 60529) Power supply see table “Specifications” DC 24 V 10 g (IEC 60068-2-6, under resonance) 1) as required 1) With GL approval and measuring range 0 ... 0.6 bar only feasible with an accuracy of 1 % 2) With GL approval only feasible for measuring range > 0 ... 1 bar Shock resistance 500 g (IEC 60068-2-27, mechanical) 100 g at -40 °C (-40 °F) Service life Measuring...
Open the catalog to page 6Optionally a T-restrictor is possible for the following process WIKA data sheet PE 81.60 • 08/2017
Open the catalog to page 7Cable outlet, OEM version, unshielded 2-wire 3-wire Legend Ub Positive power supply terminal 0V Negative power supply terminal S+ Analogue output WIKA data sheet PE 81.60 • 08/2017
Open the catalog to page 8Wetted parts < 10 bar (150 psi): Stainless steel 316L > 10 bar (150 psi): Stainless steel 316L and PH steel < 0 ... 25 bar abs. (400 psia): Stainless steel 316L Non-wetted parts ■ Stainless steel 316L ■ HNBR ■ PA For sealing materials see “Process connections” For cable materials see “Electrical connections” Pressure transmission medium < 0 ... 10 bar (150 psi): Synthetic oil > 0 ... 10 bar (150 psi): Dry measuring cell 1) not for measuring ranges < 0.6 bar and not for medium temperature -40 ...+100 °C (-40 ... +212 °F) Logo Description MTTF: > 100 years China RoHS conformity...
Open the catalog to page 9Pressure transmitter with angular connector form A with angular connector form C with angular connector form A and flange connection with M12 x 1 circular connector with standard cable outlet, unshielded with cable outlet OEM version, unshielded WIKA data sheet PE 81.60 • 08/2017
Open the catalog to page 10Process connections Female thread Female thread For information on tapped holes and welding sockets, see Technical information IN 00.14 at www.wika.com WIKA data sheet PE 81.60 • 08/2017
Open the catalog to page 11Mating connector Only use the accessories and spare parts listed, otherwise it could lead to the loss of the approval. Ordering information Model / Measuring range / Output signal / Power supply / Non-linearity / Temperature range / Process connection / Sealing / Electrical connection © 2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 12 of 12 WIKA data sheet PE 81.60 • 08/2017 IWIKAll...
Open the catalog to page 12All WIKA Alexander Wiegand SE & Co. KG catalogs and technical brochures
-
FSD-3
4 Pages
-
Model CTH6200
7 Pages
-
Calibration and service centre
16 Pages
-
Standard product portfolio
116 Pages
-
Competence in flow measurement
16 Pages
-
Management Manual
24 Pages
-
Models 111.10, 111.12
5 Pages
-
Autoclavable instrumentation
2 Pages
-
Precise. Fast. Compact.
4 Pages
-
Nuclear power generation
24 Pages
-
Machine building
52 Pages
-
Heating technology
36 Pages
-
Power generation
24 Pages
-
Innovative SF6 solutions
36 Pages
-
WIKA image brochure
16 Pages
-
990.10
6 Pages
-
SC58
3 Pages
-
CS6H, CS6L, CS6S
8 Pages
-
CS4R
5 Pages
-
CPG500
6 Pages
-
CPG1500
11 Pages
-
PM 01.15
2 Pages
-
BWX
5 Pages
-
BA, BAX
5 Pages
-
A2G-40
3 Pages
-
Portable process calibrator
4 Pages
-
Sapphire-design thermocouple
4 Pages
-
Process transmitters
12 Pages
-
EPC Contractor Business
16 Pages
-
Water & Wastewater Technology
56 Pages
-
Thermische Solarenergie
20 Pages
-
Renewable Energies
24 Pages
-
Sanitary applications
44 Pages
-
Mobile working machines
24 Pages
-
Valve test benches
12 Pages
-
Handbook Calibration technology
73 Pages
-
Electronic Pressure Measurement
74 Pages