1. Sensor Types and Models

  • Shielded and Non-Shielded variants
  • Models include IBN-M1204U and IBS-M1202U series with suffixes indicating specific features (e.g., A8MN3, B8MN3, A8VN2, B8VN2)
  • Switching types: Normally Open (N.O.), Normally Closed (N.C.), or Changeable

2. Electrical Specifications

  • Operating Voltage: 20-250VAC/DC
  • No Load Current: <2.5mA
  • Max Load Current: 100mA
  • Leakage Current: <2.5mA
  • Surge Current: 2.2A for 20ms
  • Minimum Load Current: 5mA
  • Voltage Drop: <10VAC; 8VDC
  • Switching Frequency: 25Hz AC; 40Hz DC
  • Response Time: 10ms ON / 10ms OFF
  • Switching Hysteresis: <10% (Sr)
  • Repeat Accuracy: <1.0% (Sr)
  • Temperature Drift: <15% (Sr)

3. Mechanical and Material Specifications

  • Housing Material: Nickel plated brass
  • Active Face Material: POM or PBT (depending on model)
  • Dimensions: M12×1 thread, diameter 12mm, length varies (e.g., 60mm)
  • Weight: Approx. 32g (without LED), approx. 77g (with LED)
  • Connecting Type: Micro connector or Φ2M Cable (4.0 3x0.25)

4. Environmental and Protection Features

  • Protection Category: IP67 (dust tight and water resistant)
  • Operating Temperature Range: -25℃ to +70℃
  • Short Circuit Protection: Not available (NO)

5. Additional Notes

  • Wiring diagrams referenced on pages 013 to 015 (not included here)
  • Switching distance varies by model: 4 mm for shielded, 2 mm for non-shielded
  • LED indicators available on some models for operational status

Summary of Critical Parameters

ParameterValue/Range
Operating Voltage20-250VAC/DC
Switching Distance4 mm (shielded), 2 mm (non-shielded)
No Load Current<2.5mA
Max Load Current100mA
Surge Current2.2A (20ms)
Response Time10ms ON / 10ms OFF
Protection RatingIP67
Operating Temperature-25℃ to +70℃
Housing MaterialNickel plated brass
Weight32g (without LED), 77g (with LED)

Best Practices and Recommendations

  • Ensure correct wiring according to diagrams on pages 013-015 for proper sensor operation.
  • Use sensors within specified voltage and temperature ranges to maintain performance and longevity.
  • Consider LED-equipped models for easier status monitoring.
  • Note the absence of short circuit protection; implement external protection if necessary.
  • Choose shielded or non-shielded types based on application environment and required switching distance.

Conclusion

The document details robust inductive proximity sensors suitable for industrial applications requiring reliable detection within a 20-250VAC/DC range. The sensors offer compact dimensions, IP67 protection, and various switching configurations, with options for LED indicators and different housing materials to suit diverse operational needs.

See more

Catalog excerpts

AC/DC INDUCTIVE PROXIMITY SENSOR-1

AC/DC INDUCTIVE PROXIMITY SENSOR (20-250VAC/DC) Diameter M12 2 mm 4 mm Nickel plated brass Shielded non-Shielded Switching Distance, Sn: mm Housing Material Without LED With LED M12 2 mm 4 mm Nickel plated brass 4LED 10 1/2”-20UNF No Load Current Max. Load current Leakage Current Surge Current Min. Load Current Voltage Drop Switching Frequency Response Time Switching Hysteresis Repeat Accuracy Protection Category Operating Temperature Temperature Drift Short Circuit Protection Material Active Face Connecting type Micro connector AC/DC 20-250V N.O. AC/DC 20-250V N.C. AC/DC 20-250V N.O. or N.C. Changeable * Wiring diagram number. Please see the relevant wiring diagram shown on Page 013 to Page 015.

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.