MOTORSTechnical Information Orbital Motors Type OMP, OMR and OMH
Open the catalog to page 1White is a leading global provider of motor and steering solutions that power the evolution of mobile and industrial applications around the world.
Open the catalog to page 2• Orbital Motors Features • Technical Features • Orbital Motors Application Areas • Speed, torque and output
Open the catalog to page 7• Smooth running over the entire speed range • Constant operating torque over a wide speed range • High starting torque • High return pressure without the use of drain line (high pressure shaft seal) • High efficiency • High radial and axial bearing capacity • Long life under extreme operating conditions • Robust and compact design • For applications in both open and closed loop hydraulic systems • Suitable for a wide variety of hydraulics fluids The program is characterized by technical features appealing to a large number of applications and by motors that can be adapted to a given application....
Open the catalog to page 8Speed, torque and output Speed Intermittent values Continuous values Figure 1 Maximum speed Intermittent values Continuous values Figure 2 Maximum torque WHITE can accept no responsibility for possible errors in catalogues, brochures, and other printed material. WHITE reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are the property of the respective companies. WHITE and the WHITE logotype...
Open the catalog to page 9Intermittent values Continuous values * Cylindrical 32 mm, 35 mm, 1 1/4 in or 1 1/4 in tapered shaft *** Cylindrical 35 mm, 1 1/4 in splined or 35 mm tapered shaft Figure 3 Maximum output The bar diagrams above are useful for a quick selection of relevant motor sizes for the application. The final motor size can be determined by using the function diagram for each motor size. • OMP and OMPW: see Chapter 3 OMP function diagrams • OMR and OMRW: see Chapter 8 OMR function diagrams • OMH: see Chapter 13 OMH function diagrams The function diagrams are based on actual tests on a representative number...
Open the catalog to page 10Chapter 2OMP technical dataTopics: • OMP with 25 mm and 1 in cylindrical shaft • OMP with 1 in splined and 28.5 mm tapered shaft • OMP with 32 mm cylindrical shaft • Maximum permissible shaft seal pressure • Pressure drop in OMP motor • Oil flow in drain line • Direction of shaft rotation: clockwise • Permissible shaft loads WHITE can accept no responsibility for possible errors in catalogues, brochures, and other printed material. WHITE reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent...
Open the catalog to page 1112 OMP with 25 mm and 1 in cylindrical shaftOMP 25 cm3 - 100 cm3 Type 11 Intermittent operation: the permissible values may occur for max. 10% of every minute. 2) Peak load: the permissible values may occur for max. 1% of every minute. Note: Technical data is based on splined 6B shaft WHITE can accept no responsibility for possible errors in catalogues, brochures, and other printed material. WHITE reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications...
Open the catalog to page 121) Intermittent operation: the permissible values may occur for max. 10% of every minute. 2) Peak load: the permissible values may occur for max. 1% of every minute. Technical data is based on splined 6B shaft Table 3 OMP Maximum pressures WHITE can accept no responsibility for possible errors in catalogues, brochures, and other printed material. WHITE reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this...
Open the catalog to page 1314 OMP with 1 in splined and 28.5 mm tapered shaft Type Table 4 OMP with 1 in splined and 28.5 mm tapered shaft Intermittent operation: the permissible values may occur for max. 10% of every minute. Peak load: the permissible values may occur for max. 1% of every minute. Technical data is based on splined 6B shaft. WHITE can accept no responsibility for possible errors in catalogues, brochures, and other printed material. WHITE reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes...
Open the catalog to page 1415 OMP with 32 mm cylindrical shaft Type Table 5 OMP with 32 mm cylindrical shaft Intermittent operation: the permissible values may occur for max. 10% of every minute. Peak load: the permissible values may occur for max. 1% of every minute. Table 6 OMP 25-400 Maximum pressures WHITE can accept no responsibility for possible errors in catalogues, brochures, and other printed material. WHITE reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications...
Open the catalog to page 15Maximum permissible shaft seal pressure OMP with High Pressure Shaft Seal (HPS) OMP with HPS and without drain connection: The shaft seal pressure equals the average of input pressure and return pressure. OMP with HPS and drain connection: The shaft seal pressure equals the pressure in the drain line. Figure 5 OMP with HPS and drain connection Figure 6 OMP with HPS and drain connection max. permissible shaft seal pressure OMP with standard shaft seal, check valves and without use of drain connection: The pressure on the shaft seal never exceeds the pressure in the return line. Figure 7 OMP with...
Open the catalog to page 1617 OMP with standard shaft seal, check valves and with drain connection: The shaft seal pressure equals the pressure on the drain line. Figure 8 OMP with standard shaft seal, check valves and with drain connection max. return pressure without drain line or max. pressure in the drain line 1) Intermittent operation: the permissible values may occur for max. 10% of every minute. OMP with Standard Shaft Seal OMP with standard shaft seal, check valves and without use of drain connection: The pressure on the shaft seal never exceeds the pressure in the return line Figure 9 OMP with standard shaft seal,...
Open the catalog to page 1720 Pages
32 Pages
54 Pages
53 Pages
17 Pages
19 Pages
59 Pages
42 Pages
36 Pages
36 Pages
43 Pages
28 Pages
33 Pages
20 Pages
18 Pages
22 Pages
39 Pages
53 Pages
21 Pages
65 Pages
42 Pages
36 Pages
8 Pages
14 Pages
18 Pages
15 Pages
18 Pages
22 Pages
22 Pages
26 Pages
21 Pages
27 Pages
23 Pages
18 Pages
4 Pages
7 Pages
6 Pages
259 Pages
20 Pages
14 Pages
258 Pages
6 Pages
4 Pages
20 Pages
22 Pages
16 Pages
32 Pages
204 Pages