General Purpose Contactors 53
26Pages

{{requestButtons}}

Catalog excerpts

General Purpose Contactors 53 - 1

PRODUCT SPECIFICATION General Purpose Contactors

Open the catalog to page 1
General Purpose Contactors 53 - 2

53 Series General Purpose Contactors

Open the catalog to page 2
General Purpose Contactors 53 - 3

53 Series General Purpose Contactors General Purpose Contactors 53 Se AC, ries Co 40 415V A, 1N ntacto (Coi O-1 rs l Vo NC ltage ) WERNER'S 53 series general purpose contactors are most robust, economical and readily accepted by all segments of industries where a prime mover is involved. It is an electro-mechanical switch to start a motor. Features Overview Ranging from 9 A to 150 A, built in NO & NC contacts Available with DC coil voltages in 24V, 48V & 110Voltsss looks Also coil voltages 24V, 48V, 110V, 220V, 240V, 380V & 415V AC Chatter-free operation with easy Installation and simple...

Open the catalog to page 3
General Purpose Contactors 53 - 4

53 Series General Purpose Contactors Model Number Selection Appearance

Open the catalog to page 4
General Purpose Contactors 53 - 5

53 Series General Purpose Contactors Model Number Selection Appearance

Open the catalog to page 5
General Purpose Contactors 53 - 6

53 Series General Purpose Contactors Model Number Selection Appearance

Open the catalog to page 6
General Purpose Contactors 53 - 7

53 Series General Purpose Contactors Model Number Selection Appearance

Open the catalog to page 7
General Purpose Contactors 53 - 8

53 Series General Purpose Contactors Technical Data Rated Operational Rated Operational Power Current In AC-3 Rated Number Contactor Type Operational Of Replace 53.10. to 53.20. for DC coil option. For more information refer to page no 1 - 4. *** Refer to page no 4 to choose the appropriate coil voltage.

Open the catalog to page 8
General Purpose Contactors 53 - 9

53 Series General Purpose Contactors Technical Data Contactor Type Rated Operational Voltage Replace 53.10. to 53.20. for DC coil option. For more information refer to page no 1 - 4. *** Refer to page no 4 to choose the appropriate coil voltage. 6

Open the catalog to page 9
General Purpose Contactors 53 - 10

53 Series General Purpose Contactors r Model Number Structure - Contactors 53.10.040.11.38053 Series General Purpose Contactors Coil Type Coil Voltage Current Capacity Note: DC Reversings for 80, 95, 115 and 150 A are underdevelopment. For more information about contacts, please refer to page no. 1 - 4.

Open the catalog to page 10
General Purpose Contactors 53 - 11

53 Series General Purpose Contactors Contactor Properties Contactor Type Contactor Closed Contactor Open Power Circuit & Coil Contactor Open Contactor Closed Model Number Degree Of Protection Rated Insulation Voltage (ui) Rated Impulse Withstand Voltage (uimp) Vibration Resistance 5 To 300 Hz Shock resistance ½ Sine Wave = 11 Ms Ambient Air Temperature Around The Device Without Derating Maximum Operating Altitude Operating positions Without Derating in the Following Positions *** Refer to page no 4 to choose the appropriate coil voltage. Replace 53.10. to 53.20. for DC coil option. For more...

Open the catalog to page 11
General Purpose Contactors 53 - 12

53 Series General Purpose Contactors Control Circuit Connections O O lO Contactor Type Screw clamp terminals Screw clamp terminals Connector Connector 1 input 2 input Flexible cable with cable end Spring Terminal Connections 1 conductor Flexible cable without cable end Contactor Type Rated control circuit voltage (Uc) □□ Refer to page no 1 - 4 to choose the appropriate contacts. Screw clamps type. *** Refer to page no 4 to choose the appropriate coil voltage.

Open the catalog to page 12
General Purpose Contactors 53 - 13

53 Series General Purpose Contactors DC. Control Circuit Properties Contactor Type Rated insulation voltage Properties Of Auxiliary Contacts Rated insulation voltage AC Electrical durability (valid for up to 3600 operating cycles per hour) on an inductive load) - AC-14 and AC-15 1 million operating cycles □□ Refer to page no 1 - 4 to choose the appropriate contacts. *** Refer to page no 4 to choose the appropriate coil voltage.

Open the catalog to page 13
General Purpose Contactors 53 - 14

53 Series General Purpose Contactors Pole Characteristics Rated operational current (Ie) Rated operational current (Ie) Rated operational current (Ie) □□ Refer to page no 1 - 4 to choose the appropriate contacts. 11

Open the catalog to page 14
General Purpose Contactors 53 - 15

53 Series General Purpose ContactorsTime Delay Auxiliary Contact Blocks For Connection By Screw Clamp Terminals Power Connections Notes • 53.01.33.03 and 53.01.44.03 with extended scale from 0.1 to 0.6 sec. • 53.01.33.30 with switching time of 40 ms ± 15 ms between opening of the N/C contact and closing of the N/O contact.

Open the catalog to page 15
General Purpose Contactors 53 - 16

53 Series General Purpose Contactors Auxiliary Contact Blocks Properties Auxiliary Contact Block Type Properties Front Auxiliary Timer Side Auxiliary □□ Refer to page no 9 to choose the appropriate auxiliary contacts.

Open the catalog to page 16
General Purpose Contactors 53 - 17

53 Series General Purpose Contactors Timer Operational Diagram Electronic on-delay time 53.01.33.03

Open the catalog to page 17
General Purpose Contactors 53 - 18

Suppressor Type □□ Refer to page no 1 - 4 to choose the appropriate contacts. *** Refer to page no 4 to choose the appropriate coil voltage.

Open the catalog to page 18
General Purpose Contactors 53 - 19

53 Series General Purpose Contactors Reversing Contactors Note: DC Reversing for 80, 95, 115 and 150 A are underdevelopment. Replace 53.30. to 53.40. for DC coil option. *** Refer to page no 4 to choose the appropriate coil voltage.

Open the catalog to page 19
General Purpose Contactors 53 - 20

53 Series General Purpose Contactors Interlock Description Power Connections Model Wire Range Coil Applicable Contactors Applicable Reversing Weight Number thickness Type kg □□ Refer to page no 1 - 4 to choose the appropriate contacts. *** Refer to page no 4 to choose the appropriate coil voltage.

Open the catalog to page 20
General Purpose Contactors 53 - 21

53 Series General Purpose Contactors AC Coil9 A to 18 A - 3 Poles Power Connections Coil Model No. Current Control circuit Inductance of Average resistance Weight voltage closed circuit at 20 °C ± 10 % UC 50/60 Hz A V H O kg

Open the catalog to page 21
General Purpose Contactors 53 - 22

53 Series General Purpose Contactors DC Coil 9 A to 18 A - 3 Poles Power Connections Coil Model No. Current Control circuit Inductance of Average resistance Weight voltage closed circuit at 20 °C ± 10 % UC 50/60 Hz A V H O kg

Open the catalog to page 22
General Purpose Contactors 53 - 23

53 Series General Purpose Contactors Dimensions Contactor Type □□ Refer to page no 1 - 4 to choose the appropriate contacts. Note: The dimensions for AC, DC, AC reversing & DC reversing are similar as shown above. *** Refer to page no 4 to choose the appropriate coil voltage.

Open the catalog to page 23
General Purpose Contactors 53 - 24

53 Series General Purpose ContactorsDimensions 53.10.080.°°.*** 53.10.095.°°.*** Contactor Type

Open the catalog to page 24
General Purpose Contactors 53 - 25

53 Series General Purpose Contactors Terms And Conditions Please read this catalog before purchasing any products. Please consult your WERNER representative for any clarifications or comments. Application Considerations WERNER shall not be responsible for conformity with any regulations, codes or standards that apply to use of the products. WERNER shall provide applicable third party certification documents identifying ratings and limitations of use that apply to the products in case of the customer's request. Prevent use the products for an application involving risk to life or property....

Open the catalog to page 25

All Werner Electric GmbH catalogs and technical brochures

  1. 65 Series SMPS

    27 Pages

  2. LED Light Bar

    11 Pages

  3. Contactors

    26 Pages

  4. MCB

    16 Pages

  5. Foot Switches

    10 Pages