PRODUCT SPECIFICATION Annunciator logic Controllers
Open the catalog to page 168 Series Annunciator Logic Controllers
Open the catalog to page 268 Series Annunciator Logic Controllers Annunciator Logic Controllers WERNER'S 68 series annunciator logic controller can be used for integrated alarm and supervision in various manufacturing processes. In highly automated and robotized plants, sophisticated control technology is employed to ensure safe operation. Features Overview Highly reliable in the event of emergency Sleek & economical, saves space in panel Basic module available with 16 I/P & 16 O/P Expansion module available in 16 & 8 I/P & O/P Highlights Available with many circuits & sequence patterns Programming through pre-set switches...
Open the catalog to page 368 Series Annunciator Logic Controllers General: 68 Series Annunciator Logic Controller can be used for integrated alarm and supervision in various manufacturing processes. In highly automated and robotized plants, sophisticated control technology is employed to ensure safe operation. In the event of accidental control circuit breakdown, an annunciator plays a great role in monitoring process condition until the system returns to normal conditions. Features: 1. High reliability in the event of emergency & Good human interface. 2. Good form, design and low cost. 3. Many circuits and sequence patterns...
Open the catalog to page 468 Series Annunciator Logic Controllers Specifications Item Contents Weight Weight (Approx.)
Open the catalog to page 568 Series Annunciator Logic Controllers r Model Number Structure - Annunciator Logic Controllers L. 68.16.00.01Series 68 Series Annunciator Logic Controller Main Board lO's 16 input and output Modbus Communication Protocol Model Number Selection Appearance
Open the catalog to page 668 Series Annunciator Logic Controllers Sequence Pattern & Selection Table S.No. Automatic Reset Automatic Reset Manual Reset Automatic reset first out with no subsequent alarm state 4 68 Series Annunciator Logic Control
Open the catalog to page 768 Series Annunciator Logic Controllers Sequence Pattern & Selection Table Automatic reset first out with first out flashing and reset pushbutton Alarm input (first) Lamp output (subsequent) Buzzer output Alarm Input Ring back Lamp output ri n n Lamp output (alarm) Lamp output (ringback) Manual reset first out with no subsequent alarm flashing and silence pushbutton
Open the catalog to page 868 Series Annunciator Logic Controllers Sequence Pattern & Selection Table Alarm input Lamp output Buzzer output (alarm) Buzzer output (ringback)
Open the catalog to page 968 Series Annunciator Logic Controllers Sequence Pattern & Selection Table S.No.
Open the catalog to page 1068 Series Annunciator Logic Controllers Terminal Arrangement and Input/Output Circuit INPUT TERMINALS Note : * '-' ve should be given at COM1, then the input side (A1 -A16,C1 -C4) will have a common '-' ve and '+' ve has to be given at Alarm inputs. 8
Open the catalog to page 1168 Series Annunciator Logic Controllers Terms And Conditions Please read this catalog before purchasing any products. Please consult your WERNER representative for any clarifications or comments. Application Considerations WERNER shall not be responsible for conformity with any regulations, codes or standards that apply to use of the products. WERNER shall provide applicable third party certification documents identifying ratings and limitations of use that apply to the products in case of the customer's request. Prevent use the products for an application involving risk to life or property....
Open the catalog to page 12Werner Elektrik GmbH Dorotheastraße, 2, 27568 Bremerhaven, Germany T: +49 711 - 6740 0552
Open the catalog to page 1327 Pages
22 Pages
27 Pages
16 Pages
13 Pages
11 Pages
15 Pages
12 Pages
19 Pages
7 Pages
26 Pages
17 Pages
10 Pages
24 Pages
35 Pages
11 Pages
13 Pages
26 Pages
16 Pages
15 Pages
10 Pages
16 Pages
15 Pages
11 Pages
11 Pages
19 Pages
31 Pages
50 Pages
144 Pages