Catalog excerpts
Inventing Innovation... PRODUCT SPECIFICATION Heavy Duty Limit
Open the catalog to page 1Limit Switches Limit Switches
Open the catalog to page 2Limit Switches General Purpose Limit Switches WERNER'S 441 series Heavy Duty Limit Switches have a sturdy construction comparable to any limit switch. It uses a zinc die-cast body, a glass-weave reinforced plastic head, and a cover. The terminal cover also boasts excellent dust-proof and drip-proof capabilities. Features Overview Sturdy construction comparable to any limit switch. Provides excellent dust-proof and drip-proof capabilities. Zinc die-cast body, glass-weave reinforced plastic head & cover. Highlights Highly accurate position detection is possible in these limit switches....
Open the catalog to page 3Limit Switches Model Number Selection Model Number Appearance Sealed Roller Plunger (Horizontal) Spring Wire Coil Spring Wire Limit Switches
Open the catalog to page 4Inventing Innovation.. Model Number Selection 441 series Limit Switches
Open the catalog to page 5Limit Switches Model Number Structure 441.22.00.00 Series 441 Series Heavy Duty Limit Switches 02-1NO/1NC Slow Action (Changeover) 03-1NO/1NC Slow Action (Overlapping) 04-2NC Slow Action 05-2NO Slow Action 06-3NC Slow Action 07-3NO Slow Action 00-1NO/1NC snap action 01-2NO/2NC snap action 08-2NC/1NO Slow Action (Changeover) Pin Plunger Sealed Roller Plunger (Horizontal) Plastic Rod (Point) Adjustable Roller Lever with 50mm Ø rubber roller 09-2NC/2NO Slow Action (Overlapping) Roller Lever with 50mm Ø rubber roller 10-1NC/2NO Slow Action (Changeover) Roller Lever One way Roller Lever...
Open the catalog to page 6Limit Switches Technical Data Approvals Economical, Safety Limit Switch Boasting Rigid Construction Approbations and Declaration of conformity UL CE RoHS CCC Demko • Easy-to-wire conduit opening design. • Cover, Box, and the Head mate with ridged surfaces to maintain strength. • A unique Head structure provides a large OT for smooth operation • Models with grounding terminals conform to the CE marking. • Approved by CCC. • Ideal for application in forming machines, light machines and printing machines. Between terminals of the same polarity Between currentDielectric carrying metal part...
Open the catalog to page 7Limit Switches Contact Ratings Basic models, overtravel models (except for high sensitivity models), and high-precision models Resistive load Inductive load Motor load High-sensitivity overtravel models Note:- 1.The above figures are for steady-state current. 2.Inductive loads have power factor of 0.4min (AC) and a time constant of 7 ms max. (DC). 3.A lamp load has an inrush current of 10 times steady-state current. 4.A motor load has inrush current of 6 times the steady-state current. 5.For PC loads, use the microload models. Inrush current Lamp load Note:- As an example, AC-15:2 A/250 V...
Open the catalog to page 8Limit Switches Ordering Information Coil Spring Wire Adjustable Roller Lever with 50mm Ø rubber roller Roller Lever with 50mm Ø rubber roller Sealed roller plunger (Horizontal) ● Available in sealed models. One-Horizontal operation possible. Head mounts in any of 4 directions. 25 to 140 One-Horizontal operation possible. Head mounts in any of 4 directions. Short lever One-Horizontal operation possible. Head mounts in any of 4 directions. One-Horizontal operation not possible. Head mounts in any of 4 directions. Extended Adjustable Roller Arm Fork Lever Lock ● Head mounts in any of 4...
Open the catalog to page 9Limit Switches Contact Block 02 03 1NO/1NC Slow Action 1NO/1NC Slow Action (Changeover) (Overlapping) 08 09 10 11 2NC/1NO Slow Action 1NC/2NO Slow Action 1NC/2NO Slow Action 1NC/2NO Slow Action (Changeover) (Overlapping) (Changeover) (Overlapping) Limit Switches
Open the catalog to page 10Limit Switches Dimensions and Operating Properties Pin Plunger Front Elevation Side Elevation Actuator Without LED With LED **.00 441.11.11. .01 ** Sealed Roller Plunger (Horizontal) Front Elevation Limit Switches Sealed Roller Lever Side Elevation
Open the catalog to page 11Limit Switches Dimensions and Operating Properties Plastic Rod (Point) Operating force test. F Front Elevation Side Elevation Front Elevation Side Elevation Limit Switches
Open the catalog to page 12Limit Switches Dimensions and Operating Properties Adjustable Roller Lever Front Elevation Side Elevation Front Elevation Limit Switches Side Elevation
Open the catalog to page 13Limit Switches Dimensions and Operating Properties Spring Wire Operating force test. F Front Elevation Side Elevation Spring Wire **.00 441.22.11. .01 ** Coil Spring Wire Operating force test. F Front Elevation Coil Spring Wire Side Elevation Limit Switches
Open the catalog to page 14Limit Switches Dimensions and Operating Properties Front Elevation Side Elevation **.00 441.24.11. .01 ** Adjustable Roller Lever with 50 mm Ø rubber roller Front Elevation Adjustable Roller Lever with 50 mm Ø rubber roller Limit Switches Side Elevation
Open the catalog to page 15Limit Switches Dimensions and Operating Properties Roller Lever with 50 mm Ø rubber roller Front Elevation Roller Lever with 50 mm Ø rubber roller Side Elevation Front Elevation Side Elevation Actuator Without LED With LED Roller Lever Limit Switches
Open the catalog to page 16Limit Switches Dimensions and Operating Properties Front Elevation Side Elevation Actuator Without LED With LED Front Elevation Extended Adjustable Roller Arm Side Elevation Limit Switches
Open the catalog to page 17Limit Switches Dimensions and Operating Properties Front Elevation Fork Lever Lock Side Elevation Structure Lever Resin roller Contact Form Cover Head Note: 1. The above figures are initial values. 2. The characteristics may vary depending on the model. For further details, contact your WERNER sales representative. Limit Switches
Open the catalog to page 18Limit Switches Safety Precautions Precautions for Safe Use Using Switches for Micro Loads Precautions for Correct Use • When wiring terminal screws, use M4 round crimp terminals and tighten screws to the recommended torque. Wiring with bare wires, or incorrect crimp terminals, or not tightening screws to the recommended torque can lead to short-circuits, leakage current, and fire. • When performing internal wiring there is a chance of short-circuit, leakage current, or fire, so be sure to protect the inside of the Switch from splashes of oil or water, corrosive gases, and cutting powder. •...
Open the catalog to page 19All Werner Electric GmbH catalogs and technical brochures
-
90 Series Mosaic
27 Pages
-
70-75 Series Sockets
22 Pages
-
65 Series SMPS
27 Pages
-
31 Series Stack Lights
16 Pages
-
26 Series PC Board Relays
13 Pages
-
24 Series Ultra Slim Relays
11 Pages
-
23 Series Power Relays
15 Pages
-
22 Series Relays
12 Pages
-
21 Series General Purpose Relays
19 Pages
-
290 Series PCB Power Relays
7 Pages
-
General Purpose Contactors 53
26 Pages
-
Annunciator Windows 30 Series
17 Pages
-
46 Series Foot Switches
10 Pages
-
9000 Series Mosaic
24 Pages
-
45 Series Catalogue
35 Pages
-
LED Light Bar
11 Pages
-
Annunciator Logic Controller
13 Pages
-
Contactors
26 Pages
-
MCB
16 Pages
-
Miniature Limit Switch
15 Pages
-
Foot Switches
10 Pages
-
General Purpose Limit Switches
16 Pages
-
Annunciator Windows
15 Pages
-
Miniature LED Indicators
11 Pages
-
PC Board Relays - 25 Series
11 Pages
-
20 Series - Power Relays
19 Pages
-
Capacitive Sensors
31 Pages
-
Photoelectric Sensors
50 Pages
-
Inductive Sensors
144 Pages