Analogue signal conditioning
Open the catalog to page 1Analogue signal processing Analogue signal processing Catalogue 4.1 Network-compatible current measuring transducers – ACT20C Intrinsically safe signal converters – ACT20X Signal converters and monitoring components – ACT20P Space-saving signal converters – ACT20M Signal converters in terminal format – MCZ Compact signal converter – PicoPak Process value displays Configuration software Technical appendix/Glossary Index
Open the catalog to page 3Product overview Analogue signal processing Network-compatible current measuring Page A.2 transducers – ACT20C Intrinsically safe signal converters – ACT20X Page B.2 Signal converters and monitoring components – ACT20P • Separation and conversion of current or voltage signals • Limit value monitoring, diagnosis, monitoring via Ethernet network • PC configuration with FDT/DTM software • Analogue and binary signal interfaces to Ex Zone 0 / Division 1 • FDT/DTM software configurable • 2 channel modules in 22.5 mm housing • Separation and conversion of temperature and DC signals (3-way isolation,...
Open the catalog to page 4Product overview Service and support Service connects – worldwide • Service connects – worldwide • Engineering services and customised products • easyConnect – Your Industrial Service Platform • Support Center • Additional support services • Weidmüller Configurator Digital ordering options Purchasing made easy: • Weidmüller eShop • OCI interface
Open the catalog to page 5Quick select - Analogue Signal Conditioning Selection table Network-compatible current measuring transducers - ACT20C Current and voltage transformers
Open the catalog to page 6Special characteristics X Electrical termination on mounting rail bus, ACT20C station Connection system: S = screw / Z = tension clamp / P = Push In, ILP = Input Loop Powered, OLP = Output Loop Powered, *) = in preparation
Open the catalog to page 7Quick select - Analogue Signal Conditioning Selection table Supply isolator
Open the catalog to page 8Special characteristics Connection system: S - screw / Z - tension clamp / P - Push In, ILP - Input Loop Powered, OLP - Output Loop Powered, *) - in preparation
Open the catalog to page 9Quick select - Analogue Signal Conditioning Selection table Limit switch
Open the catalog to page 10Special characteristics Connection system: S - screw / Z - tension clamp / P - Push In, ILP - Input Loop Powered, OLP - Output Loop Powered, *) - in preparation
Open the catalog to page 11Quick select - Analogue Signal Conditioning Selection table Isolation amplifier
Open the catalog to page 12Special characteristics Connection system: S - screw / Z - tension clamp / P - Push In, ILP - Input Loop Powered, OLP - Output Loop Powered, *) - in preparation
Open the catalog to page 13Quick select - Analogue Signal Conditioning Selection table Signal converters in terminal format - MCZ Frequency transducer Passive isolator Temperature transducer
Open the catalog to page 14Special characteristics Connection system: S = screw / Z = tension clamp / P = Push In, ILP = Input Loop Powered, OLP = Output Loop Powered, *) = in preparation Weidmuller XIII
Open the catalog to page 15Connection type S Screw P Push In ILP Current input, loop powered and passive („Input loop powered") OLP Current output, loop powered and passive („Output loop powered") X Power supply without CH20M mounting rail bus E Limited functionality DC Direct current supply 24 V dc AC Alternating current supply 230V ac RC Relay output („Relay contact") DO Digital output, transistor („Digital output") RCO Relay contact output DO Digital output, transistor („Digital output") SAO Current output, non-Ex („Safe analogue output") SDO Digital output, non-Ex („Safe analogue output") HDO Digital output, Ex (..Hazardous...
Open the catalog to page 16Sensor according to DIN EN 60947-5-6 (NAMUR) 3 wire 2 wire transmitter transmitter For sensors that do not have corresponding internal resistors, the following resistors can be added externally: • Parallel resistor for line break monitoring (not possible with NPN sensors and push-pull amplifier) • Series resistor for line short-circuit monitoring. These should be connected as close as possible to the sensor. Sensor types • Current Source: Sensor is an active current source • 3-wire sensor: Sensor is an active current source with additional supply via the converter • 2-wire sensor: Sensor is a...
Open the catalog to page 17Network-compatible current measuring transducers - ACT20C Network-compatible current measuring transducers - ACT20C Network-compatible current measuring Introduction A.2
Open the catalog to page 19Network-compatible current measuring transducers – ACT20C ACT20C signal conditioner with Ethernet interface Comprehensive process transparency is provided by the transfer of diagnostics information, signals and data To be able to control systems and processes optimally, you require a constant flow of information on the current states of individual applications, devices and functions. Our ACT20C signal conditioner not only monitors the signal conversion, but also communicates precise information on device status, signals and data directly to connected computer and control systems. Our Ethernet...
Open the catalog to page 20Condition monitoring Preventative maintenance strategies using automation-independent information about operating conditions and process data for connected devices. Multiple limit value monitoring The main alarm and auxiliary alarm permit precise identification of all alarm situations. Network-compatible current measuring transducers – ACT20C Smart software configuration The software configuration based on the FDT and FDT2 standards makes parameterisation, documentation and data backup easier. High process reliability A galvanic four-way isolation and an impulse withstand voltage of 6.4 kV pursuant...
Open the catalog to page 21Selection table Network-compatible current measuring transducers - ACT20C Selection table Selection table Network-compatible current measuring transducers - ACT20C Current and voltage transformers
Open the catalog to page 22| 0 | | | | | | | | | | | | X | | X | Electrical termination on mounting rail bus, ACT20C station Connection system: S = screw / Z = tension clamp / P = Push In, ILP = Input Loop Powered, OLP = Output Loop Powered, *) = in preparation