Open the catalog to page 1Enclosed Starters
Open the catalog to page 2Enclosed Starters Summary Enclosed Starters DLW - Enclosed Direct-On-Line Starters for Three-Phase Electric Motors DLWM - Enclosed Direct-On-Line Starters for Single-Phase Electric Motors Wiring Diagram Technical Data
Open the catalog to page 3Enclosed Starters Enclosed starters developed for switching and protecting three-phase and single-phase electric motors. Four thermoplastic sizes comprising most possible applications. Versions Start + Stop/Reset operation (Standard) Enclosed Starters Remote control (without buttons) Stop/Reset operation (without Start button) Hand/OFF/Auto + Start + Stop/Reset operation (Hand = Local control, OFF, Auto = Remote control)
Open the catalog to page 4Main Characteristics Thermal overload relay reset button integrated to the Stop button (sizes 02 up to 05) Compatible with CSW pushbuttons, switches and pilot lights (size 05 and 08) Allows cable connection in many different places Fast and easy installation of cable glands Degree of protection IP65 to sizes: 02, 04 and 08 and IP66 (insulated of energized parts) to size: 05. Protected against dust and water jetting. Excellent insulating properties. Enclosed size 05 allows installation of WEG electronic timers (RTW) or monitoring relays (RPW). Robust and high impact resistance. Main...
Open the catalog to page 5Applications Water Pumps and Irrigations Systems Industrial and Residential Buildings Swimming Pools Enclosed Starters
Open the catalog to page 6DLW - Enclosed Direct-On-Line Starter Three-phase starters g omposition: contactor and thermal overload relay C g Degree of protection: IP65 or IP664) g Operational voltage up to 690 V and wide control voltage available g Enclosure with UV protection and high mechanical shock resistance g hort circuit protection has to be ensured by a separate short circuit protection facility S Setting range of overload relay Orientative motor rated power 50/60 Hz1) 230 V 240 V kW/hp Size 02 Max.rated operational Reference to complete with control voltage code Weight Contactor Thermal overload relay (kg)...
Open the catalog to page 7DLW - Enclosed Direct-On-Line Starter Three-phase starters g Composition: contactor and thermal overload relay g Degree of protection: IP65 or IP663) g Operational voltage up to 690 V and wide control voltage available g Enclosure with UV protection and high mechanical shock resistance g Short circuit protection has to be ensured by a separate short circuit protection facility Setting range of overload relay Orientative motor rated power 50/60 Hz1) 230 V 240 V kW/hp Size 05 Reference to complete with control voltage code Weight Contactor Thermal overload relay (kg) Degree of protection: 65...
Open the catalog to page 8DLWM - Enclosed Direct-On-Line Starter Single-phase starters g omposition: contactor and thermal overload relay C g Degree of protection: IP65 or IP663) g Wide control voltage available g Enclosure with UV protection and high mechanical shock resistance g hort circuit protection has to be ensured by a separate short circuit protection facility S Max. rated operational Setting range of overload relay Orientative motor rated power 50/60 Hz1) 230 V Weight Reference to complete with control voltage code Thermal overload relay Setting range of overload relay Thermal overload relay Orientative...
Open the catalog to page 9Accessories Empty Enclosures Illustrative pictures Hand/OFF/Auto + Start + Stop/Reset operation Stop/Reset operation Remote control (without buttons) operation Reference code Start + Stop/Reset operation Notes: 1) A metalic plate is supplied with this empty enclosed box. Enclosed Starters
Open the catalog to page 10Wiring Diagram DLW (Three-Phase) Connected in Three-Phase Supply Sizes: 02, 04 and 08 L1 Figure 1 (phase to phase coil supply) Remote control Figure 2 (control circuit connected through a separate coil supply) - - - Made by user Notes: 1) hen using remote control, disconnect the circuit at the points marked with the “x” in figures 1 and 2 and connect the external devices (thermostat, W pushbutton, etc.), as indicated with broken lines. 2) hen using 230 V, 400 V, 500 V, on the reference code, starters will be factory-connected, as per wiring diagrams of figure 1, that is, with phase to W...
Open the catalog to page 11Wiring Diagram DLWM (Single-Phase) Connected in Single-Phase Supply Sizes: 02, 04 and 08 L1 Figure 1 (phase to phase coil supply) Remote control Figure 2 (control circuit connected through a separate coil supply) Mandatory Connection to DLW (Three-Phase) Connected in Single-Phase Supply L1 Enclosed Starters Notes: 1) hen using remote control, disconnect the circuit at the points marked with the “x” in figures 1 and 2 and connect W the external devices (thermostat, pushbutton, etc.), as indicated with broken lines. 2) hen using 230 V, 400 V, 500 V, on the reference code, starters will be...
Open the catalog to page 12Cable Knock-Outs Storage temperature Mechanical lifespan (operation) Electrical lifespan (operation) Maximum number of operation per hour Standard Operating temperature Technical Data CE, ANCE, EAC, ICONTEC, IRAM Thermoplastic enclosed material (cover and base) UV protection V0 (fire retardant) Yes (inside or outside use) Notes: 1) Limited by the thermal overload relay; 2) Only for size 05. Enclosed Starters
Open the catalog to page 13Global presence is essential. Understanding what you need, too. Global Presence With more than 30,000 employees worldwide, we are one of the largest electric motors, electronic equipments and systems manufacturers. We are constantly expanding our portfolio of products and services with expertise and market knowledge. We create integrated and customized solutions ranging from innovative products to complete after-sales service. WEG’s know-how guarantees our Enclosed Starters are the right choices for your application and business, assuring safety, efficiency and reliability. Availability is...
Open the catalog to page 14Know More High performance and reliable products to improve your production process. Excelence is to provide a whole solution in industrial automation that improves our customers productivity. Enclosed Starters
Open the catalog to page 15WEG Worldwide Operations ARGENTINA San Francisco - Cordoba Phone: +54 3564 421484 info-ar@weg.net COLOMBIA San Cayetano - Bogota Phone: +57 1 4160166 info-co@weg.net JAPAN Yokohama - Kanagawa Phone: +81 45 5503030 info-jp@weg.net SPAIN Coslada - Madrid Phone: +34 91 6553008 wegiberia@wegiberia.es Cordoba - Cordoba Phone: +54 351 4641366 weg-morbe@weg.com.ar ECUADOR El Batan - Quito Phone: +593 2 5144339 ceccato@weg.net MALAYSIA Shah Alam - Selangor Phone: +60 3 78591626 info@wattdrive.com.my SINGAPORE Singapore Phone: +65 68589081 info-sg@weg.net FRANCE Saint-Quentin-Fallavier - Isère...
Open the catalog to page 16All WEG catalogs and technical brochures
-
MTW
24 Pages
-
MOTION FLEET MANAGEMENT
16 Pages
-
CFW100 - VARIABLE SPEED DRIVE
16 Pages
-
ELECTRIC MOTORS
68 Pages
-
CFW10 Variable Speed Drive
8 Pages
-
AG10 Line
52 Pages
-
W22Xdb Flameproof Motors
23 Pages
-
Low Voltage Motor Control Center
12 Pages
-
CFW500 - VARIABLE SPEED DRIVE
32 Pages
-
Pump Genius
16 Pages
-
RW - THERMAL OVERLOAD RELAYS
28 Pages
-
CONTACTORS - CWM LINE
52 Pages
-
TURBOGENERATORS
8 Pages
-
CWB Contactors
4 Pages
-
CWB - CONTACTORS
48 Pages
-
COMPACT CONTACTORS CWC0
36 Pages
-
W22 Top Premium IE3
5 Pages
-
SOFT-STARTERS
28 Pages
-
SRW01 - SMART RELAY
28 Pages
-
MSW - SWITCH-DISCONNECTORS
36 Pages
-
Product Portfolio
16 Pages
-
WEG MANUFACTURING SITES
16 Pages
-
Energy Applications Book
32 Pages
-
SSW900 - SOFT-STARTER
20 Pages
-
CFW300 Variable Speed Drive
16 Pages
-
Geared Motors - Technical Catalogue
584 Pages
-
Drives & Controls
20 Pages
-
Solutions for Oil & Gas Industry
24 Pages
-
Energy - Products and Solutions
24 Pages
-
Solutions for Marine Indrustry
20 Pages
-
Low Voltage Switch & Control Gear
242 Pages
-
MSW - Switch Disconnectors
20 Pages
-
Smoke Extraction
4 Pages
-
Synchronous Alternators
12 Pages
-
DC Motors
8 Pages
-
ABW Air Circuit Breaker
40 Pages
-
CFW700
4 Pages
-
CFW500 Machinery Drives - VSD
16 Pages
-
This is WEG
8 Pages
-
WEG Around the World
8 Pages
-
Water Cooled Motor
8 Pages
-
Hydrogenerator
16 Pages
-
FSW - Fuse Switch Disconnectors
12 Pages
-
D and NH Fuses
8 Pages
-
DW Molded-case Circuit Breaker
36 Pages
-
DC Motor
8 Pages
-
Motors - Product Lines
24 Pages
-
WEG Motors Success Cases
60 Pages
Archived catalogs
-
DC motor
20 Pages
-
Fuse
3 Pages
-
Explosion Proof Motor
64 Pages
-
Electric transformer
8 Pages
-
Contactor
84 Pages
-
Frequency inverter
2 Pages
-
Timer
8 Pages
-
Electric generator
8 Pages
-
High Voltage Motor
20 Pages
-
Cast Iron MV Motor
20 Pages
-
Smoke Application
38 Pages
-
Appliance Motors
33 Pages
-
Electronic Softstarter
2 Pages
-
Asynchronous motor
12 Pages
-
Brake Motor
14 Pages