ABW Air Circuit Breaker
40Pages

{{requestButtons}}

Catalog excerpts

ABW Air Circuit Breaker - 1

Motors | Automation | Energy | Transmission & Distribution | Coatings

Open the catalog to page 1
ABW Air Circuit Breaker - 2

ABW Air Circuit Breaker Designed for the protection of high power electrical circuits, the ABW Air Circuit Breakers are state-of-the art products in terms of technology and design. The characteristics that make this line stand out include: Wide range of current adjustment ABW16 High short circuit breaking capacity, with Ics = Icu for the entire series ABW16 Available in two versions: FIXED and WITHDRAWABLE Microprocessed electronic protection units, with LSIG protection and the possibility for network communication Complete range of accessories ABW 3200 A

Open the catalog to page 2
ABW Air Circuit Breaker - 3

Construction Characteristics Spring loading lever Protection unit Arc extinction chambers Suspension slots TRIP indication button Operation counter Withdrawable rack (withdrawable version only) Withdrawing rail (withdrawable version only) Position indicator – Inserted / Test / Withdrawn (withdrawable version only) Spring charge indicator – Charged / Not charged Position locked by padlock (withdrawable version only) Technical data

Open the catalog to page 3
ABW Air Circuit Breaker - 4

Rated Operational Voltage - Ue (V) Rated Insulation Voltage - Ui (V) Impulse Voltage - Uimp (kV) Fixed / Withdrawable Protection units Rated service short-circuit breaking capacity - Ics (kA) Rated ultimate short-circuit breaking capacity - Icu (kA) Rated short-time withstand current - Icw (kA) Rated making capacity - Icm (kA peak) Utilisation category B Max. total breaking time Mechanical lifespan (number of operations) Electrical lifespan (number of operations) Ambient temperature Connection terminal - Fixed / Withdrawable External dimensions HxWxD (mm) 4P Standard - change position...

Open the catalog to page 4
ABW Air Circuit Breaker - 5

Selection Guide ABW16DN3-16AZ1F-A0220 Accessories – no accessories B - ON/OFF button lock K - key lock for 1 ACB K2 - key interlock for 3 ACBs M - mechanial interlock (2 breakers) M3 - mechanical interlock (3 breakers) D - door interlock BK - B+K B2 - B+K2 BM - B+M BD - B+D KM - K+M KD - K+D CP - ProfiBus communication 1) CM - ModBus communication 1) Frame sizes DN – for 1600A ES – for 2000~3200A FS – for 4000~5000A GS – for 6300A Number of poles 3 - 3 poles 4 - 4 poles Version F - Fixed E - Withdrawable Auxiliary Contacts A – 5NO+5NC Optional (withdrawable version) B – 5NO + 5NC + position...

Open the catalog to page 5
ABW Air Circuit Breaker - 6

Operation System ABW air circuit breakers operate through a spring system, which can be manually charged through a front lever, or electrically through a motor (supplied as an accessory). With the springs charged, situation in which the charge indicador shows “CHARGED”, the circuit breaker can be operated locally using the ON and OFF buttons. Remote operation is also possible, through the Open and Close coils assembled inside the circuit breaker. The closing coil has an “antipumping” electronic circuit, which prevents successive switching on a single command. Another feature of this product...

Open the catalog to page 6
ABW Air Circuit Breaker - 7

Accessories Auxiliary Contacts 1) Indicate circuit breaker status – ON or OFF. 5NO + 5NC Inductive load Alarm Contacts These contacts are incorporated into the protection units and indicate trigger occurrence for any of the protection functions. Configuration Minimum application levels Closing Coil 1) These coils allow remote closing of the circuit breaker through electrical control. This remote control is valid only if the springs of the operating mechanism is charged. Operation voltage “Anti-pumping” characteristic Yes, through electronic circuit Minimum supply time for operation (ms)...

Open the catalog to page 7
ABW Air Circuit Breaker - 8

Accessories Motor Operator The motorized drive is used for automatic charging of the circuit breaker springs operating mechanism. The operation begins immediately after curcuit breaker opening and, at the end of this process, an auxiliary contact indicates that the springs are charged. Even if the motorized operation is installed, it is still possible to charge the springs manually through the front lever. Supply Voltage Motor speed (rpm) Charge Time (to spring charging) (s) Charged Spring Auxiliary Contact It has a built-in contacts which transmits the signal to the opening, when motor...

Open the catalog to page 8
ABW Air Circuit Breaker - 9

Accessories Electrical Wiring for undervoltage time delay module 14 16 Delay trip command 0.5 Instantaneous trip command Current transformer for earth leakage protection The current transformer ABW-ZCT must be connected on ABW (protection unit AF) to measure and protect the circuit against earth leakage. T Circuit breakers Position Auxiliary Contacts Enables remote indication of circuit breaker position inside withdrawable rack. Circuit Breakers 2NO for INSERTED position Configuration 1NO for TEST position 1NO for WITHDRAWN position Contact Operation Inductive load Resistive load

Open the catalog to page 9
ABW Air Circuit Breaker - 10

Locks the circuit breaker in the OFF position. Electrical Wiring Circuit breaker

Open the catalog to page 10
ABW Air Circuit Breaker - 11

Accessories Door Frame A door frame can be fitted to cover the cut out in the panel and provide IP protection. Circuit breakers Protection degree Transparent Cover Transparent covers provide IP protection even if the breaker is in the isolated position Circuit breakers Mechanical Interlock Enables two circuit breakers to be mechanically interlocked simultaneously through a flexible cabe system. Circuit Breakers Door Interlock Prevents panel door from being opened while the circuit breaker is in operation. Circuit Breakers Communication Module The communication module has an I/O unit that...

Open the catalog to page 11
ABW Air Circuit Breaker - 12

Accessories Protection unit On ABW air circuit breakers, protection against over currents is performed through the ABW-OCR electronic protection units. The ABW-OCR AZ1 is supplied as standard for the circuit breakers from ABW16 up to ABW63 and offers protection against overload (L), timed short circuit (S), instantaneous short circuit (I), ground fault (G) and earth leakage (needs an external CT supplied as optional). These protections may be adjusted through the front dials. Other protection units are supplied as optional accessories, allowing network communication, measurements and other...

Open the catalog to page 12

All WEG catalogs and technical brochures

  1. MTW

    24 Pages

  2. AG10 Line

    52 Pages

  3. Pump Genius

    16 Pages

  4. SOFT-STARTERS

    28 Pages

  5. DC Motors

    8 Pages

  6. CFW700

    4 Pages

  7. This is WEG

    8 Pages

  8. Hydrogenerator

    16 Pages

  9. DC Motor

    8 Pages

Archived catalogs

  1. DC motor

    20 Pages

  2. Fuse

    3 Pages

  3. Contactor

    84 Pages

  4. Timer

    8 Pages

  5. Brake Motor

    14 Pages