WECON PLC Extend Module Board LX3V-2AD2DA-BD
1 / 5Pages

Catalog excerpts

WECON PLC Extend Module Board LX3V-2AD2DA-BD - 1

U'ISDV '*^*<PB y-,«t-i>.t WECON Technology Co.Ltd., SITE: http://en.we-con.com.cn Technical Support: liux@we-con.com.cn Skype: fcwkkj PHONE: 86-591-87868869

Open the catalog to page 1
WECON PLC Extend Module Board LX3V-2AD2DA-BD - 2

LX3V-2AD2DA-BD 1. Mounting instruction Make sure to power off the PLC before mounting the 2AD2DA module.and remove the top cover of PLC, screwed to the PLC. Caution: when output current, make sure that the load resistance should be less than 500Ω, otherwise the output will be lower. Warring: make sure to power off the PLC before mounting or removing the BD module.and put the cover in right place. 2. Special feature 1). LX3V-2AD2DA-BD module equips with 2 channels analog input and 2 channels analog output. This module will be mounted in the PLC. 2). The input current of LX3V-2AD2DA-BD module...

Open the catalog to page 2
WECON PLC Extend Module Board LX3V-2AD2DA-BD - 3

IN-2AD Output current range: 4~20mA IN-2DA Output current range: 4~20mA Anode of the channel 1 current input Anode of the channel 1 current output Cathode of the channel 1 current input Cathode of the channel 1 current output Anode of the channel 2 current input Cathode of the channel 2 current input Cathode of the channel 2 current input Cathode of the channel 2 current output Only one LX3V-2AD2DA-BD module in LX3V PLC can be recognized. 4. Specification 1). You may refer to the LX3V User manual for the general specification of LX3V-2AD2DA-BD. 2). Power supply from LX3V. item Specification...

Open the catalog to page 3
WECON PLC Extend Module Board LX3V-2AD2DA-BD - 4

1). Don't put the LX3V-2AD2DA-BD module near high-voltage power cable. Keep away the power cable at 2). Do not soldering any terminal with the others device. 3). Do not connect any unsuitable cable. 5). Do not connect any unit to the unused terminal. Connect to output device with AWG25-16. Max tighten torque of terminal is 0.5 to 0.6N.m. Current Input Current output The analog value(4~20mA) in each channel will be saved in system address(D8112, D8113). It will be saved automatically when "END", and convert into digital value. On the contrary process when output. caution:1. trigger M8122 and...

Open the catalog to page 4
WECON PLC Extend Module Board LX3V-2AD2DA-BD - 5

Save the value of channel 1 to DO Save the value of channel 2 to D2 Save the value of DO to channel 1 Save the value of D2 to channel 2

Open the catalog to page 5