Overview: The FI1500 Series In-Line Flow Indicator is designed for monitoring hydraulic systems up to 350 bar (5000 psi) and 400 lpm (100 US gpm). It is suitable for both mobile and industrial applications, including lubrication and coolant systems using oil. The device is reliable, minimizes contamination effects, and can be used in hazardous areas without power.
Specifications:
  • Flow Range: 10 - 400 lpm (4 - 100 US gpm)
  • Pressure: Up to 350 bar (5000 psi)
  • Accuracy: Within 4% Full Scale Deflection (FSD)
  • Temperature Range: Ambient -10 to 50°C (14 to 122°F), Fluid 20 to 80°C (65 to 176°F), intermittently up to 110°C (230°F)
  • Dimensions: 199 x 87 x 74mm
  • Weight: 3.2 kg
  • Construction: Aluminium main block, brass internal parts, Viton seals
Features:
  • Direct reading with a large 63mm dial
  • Dual scale (lpm/US gpm)
  • Horizontal or vertical mounting
  • Pressure gauge port
  • Built-in thermometer available
Operation: The flow indicator uses a sharp-edged orifice and tapered metering piston. The piston movement is proportional to the flow rate, and the orifice minimizes viscosity effects. The piston is magnetically coupled to a rotary pointer, displaying flow on a clear scale.
Installation: The unit can be mounted in any position and should be kept at least 12mm from ferrous materials to avoid magnetic interference. It should not be installed in circuits with reversed flow.
Calibration: Units are calibrated with 28cSt oil. Calibration certificates are available upon request.
Accessories: Pressure gauges can be fitted directly or connected remotely.
See more

Catalog excerpts

FI1500?Series In-Line Flow Indicator-1

FI1500 Series In-Line Flow Indicator Up to l 400 lpm, 100 US gpm l 350 bar, 5000 psi Flow Indicators are designed for continuous monitoring or intermittent use commissioning and servicing hydraulic systems up to 350 bar, 5000 psi. The large clear 63mm diameter dial ensures that quick checks can be made to determine pump performance and setting of flow control valves. They can be used on mobile and industrial hydraulic circuits. Also lubrication and coolant systems using oil. These direct acting flow indicators can be installed in hazardous areas or on applications where no power is available. The flow indicator design ensures good reliability and minimises the effects of contamination. The flow indicator consists of a sharp edged orifice and tapered metering piston. The piston movement is directly proportional to flow rate and the sharp edge orifice minimises the effects of viscosity. The piston is magnetically coupled to the rotary pointer assembly which registers on a clear 63mm (2 1/2”) scale displayed in lpm and USgpm. The FI 1500 flow indicators should not be installed in circuits where the flow is reversed. See RFI series for reversible operation. Milwaukee, WI 53235, USA Tel: +1 (414) 769-6400 [email protected] St. Ives, Cambs. PE27 3LZ, UK Tel: +44 (0) 1480 397 400 [email protected] Features l FLOW: 10 - 400 lpm, 4 - 100 US gpm l PRESSURE: 350 bar, 5000 psi l ACCURACY within 4% FSD l BUILT-IN thermometer available l DIRECT reading l DUAL scale lpm/US gpm l HORIZONTAL or vertical mounting l LARGE clear dial l LOW cost rugged design l PRESSURE gauge port l WIDE operating range Hydraulic measurement and control

 Open the catalog to page 1
FI1500?Series In-Line Flow Indicator-2

Model Number Model number with temperature without temperature Calibrated flow range LPM US gpm Main ports Top port Note - All NPTF threads are to ANSI B1.20.3 -1976 Class 1. As stated in the standard it is recommended that “sealing is accomplished by the means of a sealant applied to the thread”. NPT fittings may also be used to connect to NPTF ports (also with a sealant applied to the thread) Functional specification Ambient temperature: -10 to 50°C (14 to 122°F) Fluid type: Hydraulic oils Fluid temperature: 20 to 80°C (65 - 176°F) continuous use. Intermittently (<10 minutes) up to 110°C (230°F)...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.