Overview: The DHCR Series Digital Tester is designed for accurate measurement of flow, pressure, temperature, and speed in hydraulic systems. It is used for diagnosing faults in hydraulic pumps, motors, valves, and hydrostatic transmissions, aiding in preventative maintenance and reducing downtime.
Key Features:
  • Accurate flow measurement with 1% reading accuracy due to automatic linearisation.
  • Internal oil by-pass for system protection against over-pressure.
  • Bi-directional testing capability up to 480 bar and 1500 lpm.
  • Remote inputs for flow, temperature, pressure, and speed.
  • Low power consumption with automatic power-off feature.
  • Portable and lightweight with aluminium and steel construction.
  • Infra-red phototachometer with 'On Target' indicator.
Functional Specifications:
  • Operating temperature: 15 to 40°C (59 to 104°F).
  • Inputs: 1 pressure, 1 speed, 2 flow, and temperature.
  • Selectable engineering units for flow and temperature.
  • Dimensions: 200mm x 160mm x 90mm; Weight: 2.6 kg.
  • Construction material: Painted mild steel; Seals: Viton.
Model Specifications:
  • DHCR-6: Max Pressure 420 bar, 6000 psi.
  • DHCR-7: Max Pressure 480 bar, 7000 psi.
Operation: The DHCR Testers use microprocessor-based technology for flexibility and high accuracy. Data is displayed on an 8-digit LCD, with temperature permanently shown. The device features a plastic membrane keypad and a sealed surface, with a display refresh rate of one second, or 1/3 second for fast updates. It uses low power micro-circuitry to minimize battery consumption, with automatic shut-off after one hour of inactivity.
Calibration: The DHCR accepts 'K factor' from LT/LTR turbine blocks for calibrated flow measurement. Units are calibrated with 21 csi oil as standard.
Accessories: Includes a range of turbine flow blocks (LT and LTR), temperature sensors, speed sensors (Phototachometer - TH3), cables and hoses in various lengths, and a heavy-duty carry case.
See more

Catalog excerpts

DHCR Series Digital hydraulic readout-1

DHCR Series Digital hydraulic readout For use with LT and LTR flow blocks www.webtec.com The DHCR Series Digital Tester with remote flow block accurately measures flow, pressure, temperature and speed. Our testers are designed for checking hydraulic pumps, motors, valves and hydrostatic transmissions. This easy to use diagnostic unit can pin point hydraulic system faults, reduce downtime and help in preventative maintenance. Main hydraulic circuits, drain leakage flows and dual pumps can be measured simply at the turn of a switch. The readout can be used in the most convenient position; for example, in the cab of a vehicle, with the flow blocks installed anywhere in the circuit. The tester comprises a digital readout with two flow inputs and one flow block connected remotely by a 2 metre long cable and micro-bore hose assembly to the left hand side of the readout. An optional flow block can be connected via a cable to the front of the readout. Flow inputs can be easily calibrated by the operator to a wide range of our flow blocks. The readout is scaled in lpm, gpm, US gpm, selected by push button. In addition to the range of flow blocks, other optional accessories include hoses, pressure loading valves and a phototachometer. Features l ACCURATE measurement of flow, with automatic linearisation giving an accuracy of 1% of reading over a wide range. l INTERNAL oil by-pass protects the system, tester and operator against overpressure. l BI-DIRECTIONAL for unrestricted connection and simplified testing up to 480 bar and 1500 lpm. l FAST checks on pumps, motors, valves, cylinders and hydrostatic transmissions. l REMOTE INPUTS 2 - Flow and Temperature 1 - Pressure 1 - Speed l ECONOMICAL low power consumption from standard battery. Automatic “Power Off’ feature. l PORTABLE AND LIGHTWEIGHT Aluminium and steel construction. DHCR Digital Readout l INFRA-RED PHOTOTACHOMETER with ‘On Target’ Indicator. Optional LTR flow block Hydraulic measurement and control

 Open the catalog to page 1
DHCR Series Digital hydraulic readout-2

Specifications Model number DHCR-6 DHCR-7 Functional specification Operating specification for all parts Ambient temperature: 15 to 40°C (59 to 104°F) Inputs: 1 pressure, 1 speed, 2 flow and temperature Max pressure: Model dependant see table above Engineering units: (selectable) Flow: lpm, US gpm, I gpm Temperature: °C or °F Dimensions: 200mm x 160mm x 90mm (7.8” x 6.3” x 3.5”) Weight: 2.6 kg (5.7 lbs) Construction material: Case - Painted mild steel Seals: Viton units are calibrated with 21 csi oil as standard. DHCR Testers are microprocessor based instruments providing flexibility and high...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.