flow-captor 4115 S103 + 4015.3x S103
3Pages

{{requestButtons}}

Catalog excerpts

flow-captor 4115 S103 + 4015.3x S103 - 1

Flow meter for TRI-Clamp® System / EHEDG certified flow-captor 4115 S103 + 4015.3x S103 The flow-captor 4115 S103 + 4015.3x S103; ideal for all measurement and control tasks within automation processes in the food industry in order to control liquid media. Application under EHEDG conditions - see additional text. The sensor has been specially designed for Tri-Clamp® connection systems. It works according to the calorimetric measuring principle, which allows the adjustment of the measuring range to a large quantity spectrum. The flow-captor works fully electronically and without mechanically moved parts.        EHEDG certified Type EL CLASS I April 2019 precise flow measurement adjustable measuring range analog current or voltage output for medium temperature up to max. 275 °F (135 °C) robust stainless steel construction (special encapsulation) ISO 9001 : 2015 Technical data Type Medium Sensor data Measuring range Adjustibility Medium temperature Pressure Response time Linearity deviation Repeatability Temperature drift Mechanical data Protection class Material housing elektronics Material housing / sensor Material of sensor head Material TC - closure TC closure size Sensor cable Electrical connection Housing dimensions Electrical data Operating voltage Power consumption Ready for operation Output 4015.30 Load 4015.30 Output 4015.31 Load 4015.31 Protection circuit Output display * 1) data relate to water cont. adjustable from 0 - 20 cm/s to 0 - 200 cm/s1) cont. adjustable from 0 to 200 cm/s2) other range on request stepless from 10 % - 100 % by means of zero point and measuring range potentiometer max. 275 °F (135 °C) max. 30 bar 2 -10 sec. depends on measuring conditions < 5 % most favourable straight line related to the final value <2% < 0.3 % K IP65 Makrolon® stainless steel AISI 303 stainless steel AISI 316L (electro-polished) stainless steel AISI 316L (electro-polished) Ø50.5 mm or Ø64.5 mm 2 m encapsulated, shielded silicone cable 3 x 0,5 mm² terminal block see drawings (other versions on request) 24 VDC ±10 % approx. 100 - 200 mA (at max. flow) approx. 10 sec. after power connection 4 - 20 mA max. 600 Ω 0.1 - 10 V ≥ 100 KΩ reverse polarity & short circuit / overload protected up to max. 30 VDC only green LED calibrated with insulation oil type "Shell Diala S4 ZX-I" www.captor.de info@captor.de DE-25377 Kollmar, Germany Tel.: +49 (0)4128 - 591· Fax: - 593 Sensors GmbH Strohdeich 32 sales@captor.co.uk Tel.: +44 (1704) - 551684 · Fax: - 551297 Merseyside PR8 4DU, UK 66 Eastbourne Road, Southport Sensors Ltd. Sensors LLC. 4462 Bretton Court, Building 1, Suite 7 Acworth, Georgia 30101, USA Tel.: +1 (770) 592 - 6630 · Fax: - 592 6640 sales@captor.com Technical

Open the catalog to page 1
flow-captor 4115 S103 + 4015.3x S103 - 2

Flow meter for TRI-Clamp® System / EHEDG certified 4115 S103 Load .30 output max. 600 Ω load output .31 ≥ 100K-Ohm Bürde Ausgang .30 max. 600 Ω Last Ausgang .31 ≥ 100K-Ohm Material Sensorkopf und Flansch WN 1.4404 Material Gehäuse Edelstahl WN 1.4305 Material of sensor head and flange AISI 316L Material of housing stainless steel AISI 303 www.captor.de info@captor.de DE-25377 Kollmar, Germany Tel.: +49 (0)4128 - 591· Fax: - 593 Sensors GmbH Strohdeich 32 sales@captor.co.uk Tel.: +44 (1704) - 551684 · Fax: - 551297 Merseyside PR8 4DU, UK 66 Eastbourne Road, Southport Sensors Ltd. Sensors...

Open the catalog to page 2
flow-captor 4115 S103 + 4015.3x S103 - 3

Flow meter for TRI-Clamp® System / EHEDG certified flow-captor 4115 S103 + 4015.3x S103 Zusatztext für die Anwendung unter EHEDG - Bedingungen Additional text for the application under EHEDG conditions DIN Klemmstutzen, kurz DIN 32676 (DN 50) DIN Clamp ferrule, short DIN 32676 (DN 50) Hinweis für den Einsatz des Sensors nach EHEDG (European Hygienic Engineering and Design Group) Der Sensor ist EHEDG zertifiziert. Diese Zertifizierung gilt NUR bei Verwendung von EHEDG zertifizierten Adaptern und Dichtungen. Zur Vermeidung von Toträumen nur DIN Klemmstutzen, kurz (DN 40 oder DN 50), DIN...

Open the catalog to page 3

All Weber Sensors GmbH catalogs and technical brochures

  1. PAX DP

    1 Pages

  2. foto-captor

    2 Pages

  3. foto-captor

    2 Pages