Specifications:
The document outlines various types of foto-captors, each with specific ambient temperature ranges from -30°C to +85°C (-22F to 185F). The housing is made of 1.4541 stainless steel, with all parts encapsulated. It meets shock and vibration standards per DIN 57.411 and has a protection standard of IP65 / DIN 400 50. The device includes a green LED function indicator and a red LED overload indicator. Electrical connections are available via molded armored silicone cable or connection socket.

Procedures:
The foto-captors are designed to operate with different temperature ranges, viewing angles, housings, cooling jackets, and electrical outputs. They can be supplied with or without fiber optics, and with integral or remote lens systems. The type code is crucial for identifying the specific unit.

Technical Data:
Electrical output and set-point temperatures vary by type code, with minimum temperature responses ranging from 270°C to 800°C. Optical data includes various viewing angles and scanned areas at different distances. Electrical data specifies voltage, output type, supply voltage, load current, and switching frequencies.

Design Options:
Available design options include standard housing, cooling jackets, remote electronics units, remote lenses, and swivel stands.

Charts and Graphs:
Chart B illustrates the increase in set-point temperature required based on the percentage of the scanned area containing the hot product. For example, a foto-captor type 1331.- requires a set-point temperature of 450°C when the scanned area is fully covered by the hot product, but if only 5% is covered, an additional 250°C is needed, making the effective response temperature 700°C.

Contact Information:
For further inquiries, contact Weber Sensors LLC at 4462 Bretton Court Building 1, Ste 7, Acworth, GA 30101, Phone: +1(770)592-6630, Fax: -6640, Email: [email protected], Website: www.captor.com.
See more

Catalog excerpts

Data sheet foto-captor-1

raptor foto-captor Scanned Area at Various Distances Chart A foto-captor compact version Temperature Response Curve Chart B foto-captors are available with different temperature ranges, viewing angles, housings, cooling jackets and electrical outputs. They are supplied with and without fiber optics, integral or remote lens systems. The "Type Code" is used to identify the part number of your desired unit. Type code foto-captor temperature range viewing angle desisn 1 i i i ir~ ____\m\ electrical output Technical Data Chart B illustrates the increase in set-point temperature, required to operate the foto-captor, relative to the percentage of the scanned area containing the hot product. Example: foto-captor type 1331.-response temperature, when scanned area is covered 100% by hot product = 450 °C However, if only 5% of scanned area contains hot product, the foto-captor requires an additional (from chart above): 250 °C Set-point temperature: +450 °C Effective response temperature is therefore: 700 °C

 Open the catalog to page 1
Data sheet foto-captor-2

foto-captor compact version Design Options Cooling Jacket Swivel Stand % -Ju pp ip weber Sensors LLC_ Member of the captor Group Type code Optical Data Type code V* = vertical S* = horizontal FOC* = standard length 2m (6.5 ft.) see table FOC foto-captor Design Type code Electrical Data Type code Test Circuit Internal voltage supply Technical data is subject to change 04/2002 -foto-captor compact -US © Copyright 2002 by captor Management Inc. 4462 Bretton Court Building 1, Ste 7 • Acworth, GA 30101 Phone: +1(770)592-6630 • Fax: -6640 • E-mail: [email protected] • ww

 Open the catalog to page 2

All Weber Sensors GmbH catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.