1. Catalogs
  2. weber Sensors GmbH
  3. Data sheet flow-captor 412x.1x 2021

Data sheet flow-captor 412x.1x 2021

Data sheet flow-captor 412x.1x 2021

Data sheet flow-captor 412x.1x 2021

Product catalog summary
Overview: The document provides technical specifications and operational details for the flow-captor 412x.1x, a flow switch designed for monitoring liquid media in industrial applications. It operates on the calorimetric measuring principle and is fully electronic with no moving parts.
Specifications:
  • Measuring Range: Adjustable from 0 - 20 cm/s to 0 - 300 cm/s for water-based media and 0 - 30 cm/s to 0 - 300 cm/s for oil-based media.
  • Set-point Range: Approximately 15% - 90% of the range setting.
  • Temperature: Medium temperature ranges from -20°C to +80°C, with a special version (S101) allowing up to 130°C.
  • Pressure: Maximum of 100 bar (1450 PSI).
  • Response Time: 2 to 10 seconds depending on the range setting.
  • Protection Class: IP65.
  • Material: Housing made of glass fibre reinforced PBTP, sensor head of stainless steel AISI 303.
Features:
  • Precise switching flow monitor with high accuracy even at slower flows.
  • Separate adjustment of set point and range with LED display for flow and switching point.
  • Robust industrial design with special encapsulation.
  • ISO 9001:2015 certified.
Sensor Head Options:
  • Available with ½” BSP thread as standard, with extended probes and NPT thread options.
  • ¼” BSP thread available for smaller pipes.
Electrical Data:
  • Operating Voltage: 18 to 30 VDC.
  • Current Consumption: Maximum 150 mA (pulsed).
  • Power Consumption: Approximately 1 W.
  • Switching Current: ≤ 400 mA.
  • Circuit Protection: Includes reverse polarity, short circuit, and overload protection.
Installation and Operation:
  • Easy installation via T-piece or welded fitting.
  • Initial operation approximately 10 seconds after power connection.
Additional Information: The document includes contact details for Sensors GmbH, Sensors Ltd., and Sensors LLC, with locations in Germany, the UK, and the USA.
See more

Catalog excerpts

Data sheet flow-captor 412x.1x 2021-1

Flow switch for liquid media flow-captor 412x.1x The flow-captor 412x.1x is ideally suited for use in automation processes or other industrial applications where liquid media must be monitored. The sensor works according to the calorimetric measuring principle, fully electronic and without mechanically moving parts. The flow-captor detects the flow velocity of the medium and converts it into an electrical signal.        precise switching flow monitor high switching accuracy even with slower flows separate adjustment of set point and range display of the flow and the switching point via LED chain LED for output status robust industrial design (special encapsulation) ISO 9001:2015 Control and Display Panel LED-chain for display of flow range Measuring range adjusted to 3 m/s = 100 % (9. LED) Flashing LED for display of adjusted set-point Set-point adjusted to 50 % of end value (5. LED) Potentiometer for flow setpoint Potentiometer for adjustment of measuring range from .2 to 3 m/s LED for display of output status Flow speed equates 75 % (7. LED) Green LED is ON: Flow rate is above the adjusted set-point. Sensor heads 1/2“ BSP thread standard size 1/4“ BSP thread for smaller pipe diameter The sensor head is constructed of only one piece of electropolished stainless steel and without any sensor element intruding into the medium. Easy installation by means of T-piece or welded fitting. The flow-captor 412x.1x is available with different sensor head For aggressive media other materials can be offered on versions: request.     ½“ BSP thread – standard size – extended sensor probes with ½“ BSP thread are available NPT thread as option ¼” BSP thread for smaller pipes The housing is constructed of glass fibre reinforced PBTP (Ultradur ®). The electronics inside is completely epoxy resin encapsulated. flow-captor 412x.1x S101 Cooling version for medium temperature up to 130 °C www.captor.de [email protected] Tel.: +49 (0)4128 - 591· Fax: - 593 DE-25377 Kollmar Sensors GmbH Strohdeich 32 [email protected] Tel.: +44 (1704) - 551684 · Fax: - 551297 Merseyside PR8 4DU, UK 66 Eastbourne Road, Southport Sensors Ltd. Sensors LLC. 4462 Bretton Court, Building 1, Suite 7 Acworth, Georgia 30101, USA Tel.: +1 (770) 592 - 6630 · Fax: - 592 6640 sales@ca

 Open the catalog to page 1
Data sheet flow-captor 412x.1x 2021-2

Flow switch for liquid media flow-captor 412x.1x Technical data Type Medium Sensor data Measuring range Set-point range Medium temperature Ambient temperature Pressure Response time Linearity deviation Repeatability tolerance Hysteresis Temperature drift Mechanical data Protection class Material: Housing Material: Sensor head 0 - 20 cm/s to 0 - 300 cm/s, 0 - 30 cm/s to 0 - 300 cm/s, continuously adjustable *2 continuously adjustable *1 approx. 15 % - 90 % of range setting approx. 15 % - 90 % of range setting -20 °C to +80 °C -20 °C to +70 °C max. 100 bar (1450 PSI) 2 sec. - 10 sec. depending...

 Open the catalog to page 2
Data sheet flow-captor 412x.1x 2021-3

Flow switch for liquid media flow-captor 412x.1x Connection diagram: www.captor.de [email protected] Tel.: +49 (0)4128 - 591· Fax: - 593 DE-25377 Kollmar Sensors GmbH Strohdeich 32 [email protected] Tel.: +44 (1704) - 551684 · Fax: - 551297 Merseyside PR8 4DU, UK 66 Eastbourne Road, Southport Sensors Ltd. Sensors LLC. 4462 Bretton Court, Building 1, Suite 7 Acworth, Georgia 30101, USA Tel.: +1 (770) 592 - 6630 · Fax: - 592 6640 [email protected] Technical data subject to alteration! Rev. AN 27.06.19

 Open the catalog to page 3

All Weber Sensors GmbH catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.