Flow switch for liquid media flow-captor 4120A S100 S110/xx + 402x.1x S100 The flow-captor type 4120A S100 S110/xx + 402x.1x S100 is a separate system consisting of sensor and electronics. The sensor is used in automation processes where liquid media have to be controlled or monitored. The electronic sensor works according to the calorimetric measuring principle and without any mechanically moved parts. The sensor detects the flow velocity of the medium and converts it into an electrical signal. • • • • • • • for medium temperature up to max. 140 °C / 284 °F (S100) extended sensor, 20 - 90 mm (S110/xx) pressure resistant up to 100 bar / 1470 psi defined switching signal temperature-independent robust design: fully encapsulated sensor and electronics ISO 9001:2015 Technical data Type Medium Sensor data Measuring range Set-point range Pressure Response time Linearity deviation Repeatability tolerance Hysteresis Temperaturdrift Mechanical data Protection class sensor Protection class electronics Material: housing Material: sensor probe Sensor probe sizes 0 - 30 cm/s bis 0 - 300 cm/s,continuously 0 - 20 cm/s bis 0 - 300 cm/s, continuously adjustable*2 adjustable*1 approx. 15 % - 90 % of range setting max. 100 bar (1450 PSI) 2 sec. - 10 sec. depending on range setting 2 sec. - 15 sec. depending on range setting < 5 % *2 < 5 % *1 <2% approx. 10 % < 0.3 % per Kelvin IP67 IP65 ABS stainless steel AISI 316Ti (other material on request) a) flow-captor 4120 / ¼" BSP Length 20 mm, ¼" BSP b) flow-captor 4120 / ½" BSP Length 30 mm, ½" BSP c) flow-captor 4120 / ½" BSP S110/45 Length 45 mm, ½" BSP d) flow-captor 4120 / ½" BSP S110/67 Length 67 mm, ½" BSP Electrical connection Body dimensions Electrical data Operating voltage Current consumption Power consumption Switching current Circuit protection Voltage drop Initial operation e) flow-captor 4120 / ½" BSP S110/90 Length 90 mm, ½" BSP screw terminal block H120 x B80 X T56 (drawing K70031) 18 to 30 VDC, incl. residual ripple max. 150 mA (pulsed) approx. 1 W ≤ 400 mA reverse polarity, short circuit and overload reverse < 2.5 V at max. load approx. 10 sec. after connection of power Electrical output *1 relate to water *2 relate to „Shell Diala S4 ZX-I“ www.captor.de [email protected] Tel.: +49 (0)4128 - 591· Fax: - 593 DE-25377 Kollmar Sensors GmbH Strohdeich 32 [email protected] Tel.: +44 (1704) - 551684 · Fax: - 551297 Merseyside PR8 4DU, UK 66 Eastbourne Road, Southport Sensors Ltd. Sensors LLC. 4462 Bretton Court, Building 1, Suite 7 Acworth, Georgia 30101, USA Tel.: +1 (770) 592 - 6630 · Fax: - 592 6640 [email protected] Technical data subject
Open the catalog to page 1Flow switch for liquid media Temperature data Type Medium temperature in relation to ambient temperature 4120A S100 S110/xx + 402x.1x S100 Medium temperature max. Ambient temperature max. 140 °C / 284 °F 20 °C / 68 °F 130 °C / 266 °F 30 °C / 86 °F 120 °C / 248 °F 40 °C / 104 °F 110 °C / 230 °F 50 °C / 122 °F 100 °C / 212 °F 60 °C / 140 °F 90 °C / 194 °F 70 °C / 158°F Medium temperature min. Ambient temperature min. -20 °C / -4 °F -20 °C / -4 °F -30 °C / -22 °F -10 °C / 14 °F www.captor.de [email protected] Tel.: +49 (0)4128 - 591· Fax: - 593 DE-25377 Kollmar Sensors GmbH Strohdeich 32 [email protected]...
Open the catalog to page 29 Pages
6 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
6 Pages
12 Pages