Data sheet flow-captor 4120.1xA S114/xx S110/xx - 1

Flow switch for TRI-CLAMP® System / EHEDG certified flow-captor 4120.1xA S114/xx S110/xx The flow-captor type 4120.1xA S114/xx S110/xx is ideally suited for use in automation processes in the food industry where liquid media must be monitored. The sensor was specially designed for TRI-CLAMP® connections. Application under EHEDG conditions - see additional text. The sensor operates according to the calorimetric measuring principle, fully electronically and without mechanically moved parts. The flow-captor detects the flow velocity of the medium and converts it into an electrical signal. • • • • • • • • EHEDG certified TYPE EL Class I April 2019 precise switching flow monitor high switching accuracy even with lower flows separate setting for set-point and range display of flow condition and adjusted switch point via LED chain LED for output status robust industrial version (special potting) ISO 9001:2015 Technical data Type 4120.1xA S114/xx S110/xx Medium water-based Sensor data Measuring range 0 - 20 cm/s to 0 - 300 cm/s, continuously adjustable1) Medium temperature -20 °C to +130 °C / -4 °F to +266 °F Ambient temperature -20 °C to +70 °C / -4 °F to +158 °F Set-point range approx. 15 % - 90 % of range setting Pressure up to 100 bar Response time 2 sec. - 10 sec., according to range setting Linearity deviation < 5 % 1) Repeatability <2% Hysteresis approx. 10 % Temperature drift < 0.3 % / K Mechanical data Protection class IP65 Material housing PBTP, glass fibre reinforced ( Ultradur ® ) Material sensor head stainless steel 316L, electropolished Flange diameter D50.5 mm / D64.0 mm Cable connection integrated plug assembly with PG9 fitting, 2 m oilflex cable 3 x 0.5 mm² Electrical data ( Electronic unit ) Operating voltage 18 to 30 VDC, incl. residual ripple Current consumption max. 150 mA (pulsed) Power consumption approx. 1 W Switching current ≤ 400 mA Circuit protection reverse polarity, short circuit and overload Voltage drop < 2.5 V at max. load Initial operation approx. 10 sec. after connection of power Electrical output .12 .13 currentless, not switched Switching condition with flow < switching point energized, switched off LED off Switching condition with flow > switching point currentless, not switched energized, switched LED green green 1) www.captor.de info@captor.de DE-25377 Kollmar, Germany Tel.: +49 (0)4128 - 591· Fax: - 593 Sensors GmbH Strohdeich 32 sales@captor.co.uk Tel.: +44 (1704) - 551684 · Fax: - 551297 Merseyside PR8 4DU, UK 66 Eastbourne Road, Southport Sensors Ltd. Sensors LLC. 4462 Bretton Court, Building 1, Suite 7 Acworth, Georgia 30101, USA Tel.: +1 (770) 592 - 6630 · Fax: - 592 6640 sales@captor.com Technical data subject t

Open the catalog to page 1
Data sheet flow-captor 4120.1xA S114/xx S110/xx - 2

Flow switch for TRI-CLAMP® System / EHEDG certified flow-captor 4120.1xA S114/xx S110/xx Connection diagram: Horizontal mounting for a better cooling effect! Please note that the ratio of the ambient temperature to the medium temperature is maintained! max. ambient temp. www.captor.de info@captor.de DE-25377 Kollmar, Germany Tel.: +49 (0)4128 - 591· Fax: - 593 Sensors GmbH Strohdeich 32 sales@captor.co.uk Tel.: +44 (1704) - 551684 · Fax: - 551297 Merseyside PR8 4DU, UK 66 Eastbourne Road, Southport Sensors Ltd. Sensors LLC. 4462 Bretton Court, Building 1, Suite 7 Acworth, Georgia 30101, USA...

Open the catalog to page 2
Data sheet flow-captor 4120.1xA S114/xx S110/xx - 3

Flow switch for TRI-CLAMP® System / EHEDG certified flow-captor 4120.1xA S114/xx S110/xx Zusatztext für die Anwendung unter EHEDG - Bedingungen Additional text for the application under EHEDG conditions DIN Klemmstutzen, kurz, DIN 32676 (DN 40 (siehe Zeichnung) oder DN 50) DIN Clamp ferrule, short, DIN 32676 (DN 40 (see drawing)or DN 50) Hinweis für den Einsatz des Sensors nach EHEDG (European Hygienic Engineering and Design Group) Der Sensor ist EHEDG zertifiziert. Diese Zertifizierung gilt NUR bei Verwendung von EHEDG zertifizierten Adaptern und Dichtungen. Zur Vermeidung von Toträumen...

Open the catalog to page 3

All Weber Sensors GmbH catalogs and technical brochures

Archived catalogs