1. Catalogs
  2. Wayne Combustion Systems
  3. HSG200 and HSG400 Gas Powered Burners

HSG200 and HSG400 Gas Powered Burners

HSG200 and HSG400 Gas Powered Burners

HSG200 and HSG400 Gas Powered Burners

Product catalog summary
Specifications and Features:
The Wayne Model HSG power gas burners are engineered for high performance and reliability. Key features include higher static air pressure compared to standard burners, effective combustion in low draft conditions, and the ability to use both LP and Natural Gas. The burners have a flame retention head for adaptable flame shapes and positive premixing of gas and air for optimal combustion (9 to 11% CO2 on Natural Gas).
Serviceability:
The design allows for easy service without removing the burner. The "Gas Gun" assembly can be easily removed for servicing or component replacement. External orifice changes are straightforward, and combustion components align automatically. Primary air adjustment is facilitated with an indicator.
Installation Flexibility:
The burners offer flexibility with orifice changes and adjustments to accommodate LP or Natural Gas across a range of 60M to 400M Btu/hr. They come with a complete range of marked orifice sizes and a primary air inlet designed for optional outside air intake. Components are industry-proven for performance and reliability, and an automatic off-cycle air damper minimizes efficiency loss.
Technical Specifications:
Models include HSG 200 (60M to 200M Btu/hr) and HSG 400 (200M to 400M Btu/hr). They are supplied fully assembled and test-fired, with additional orifices and a combination redundant gas valve and ignition control package. The burners are individually cartoned, weigh 26 lbs, and are shipped 18 per pallet. They feature a 24-volt combination control, flamerod sensor with a 4-second safety shutdown, and direct spark ignition with a 7300-volt transformer. The motor operates at 3450 RPM, 115V, 2.44. The fan housing is made of aluminum alloy, and the air tube is available in standard lengths of 6", 9", and 12".
Model and Part Information:
Part numbers and corresponding model numbers are provided for different tube lengths and capacities, ranging from 60-200 M Btu/hr to 200-400 M Btu/hr.
See more

Catalog excerpts

HSG200 and HSG400 Gas Powered Burners-1

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:11.00pt "Arial Black", sans-serif; } .font1 { font:4.00pt "Trebuchet MS", sans-serif; } .font2 { font:5.00pt "Trebuchet MS", sans-serif; } .font3 { font:9.00pt "Trebuchet MS", sans-serif; } .font4 { font:10.00pt "Trebuchet MS", sans-serif; } .font5 { font:11.00pt "Trebuchet MS", sans-serif; } .font6 { font:12.00pt "Trebuchet MS", sans-serif; } .font7 { font:38.00pt "Trebuchet MS", sans-serif; } Model HSG 200/400 GAS BORNER The Wayne Model HSG power gas burners are designed for performance and reliability, and offer features such as: Higher static air pressure than standard power gas burners Օ Good combustion in poor draft situations Capability to fire LP or Natural Gas Օ Flame rtention head to allow flame shapes to fit various combustion chambers Combustion SY§mm§ A Sam »w 鋣&m%m$y WE TAME THE FLAME Bwesmem Positive premixing of gas and air to provide excellent combustion characteristics (9 to 11 % CO2 on Natural Gas) Designed For Easy Servlceabilhy: Օ No need to remove the burner for normal service - "Gas Gun" assembly is easily removed for complte service or replacement of components Easy, external orifice change « Automatic, perfect alignment of combustion components 蕕 Primary air adjustment with indicator Designed For installation Flexibiiity: Just change the orifice and adjust to fire LP or Natural Gas through the full burner range from 60M to 200M Btu/hr and 200M to 400M Btu/hr Օ Complte range of marked orifice sizes supplied with each HSG burner » Primary air inlet designed for optional outside air intake Industry proven components for excellent performance and reliability 蕕 Automatic off-cycle air damper to minimize efficiency loss and provide maximum installation flexibiiity C us

 Open the catalog to page 1
HSG200 and HSG400 Gas Powered Burners-2

table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:11.00pt "Arial Black", sans-serif; } .font1 { font:12.00pt "Franklin Gothic Medium", sans-serif; } .font2 { font:4.00pt "Trebuchet MS", sans-serif; } .font3 { font:6.00pt "Trebuchet MS", sans-serif; } .font4 { font:9.00pt "Trebuchet MS", sans-serif; } .font5 { font:10.00pt "Trebuchet MS", sans-serif; } .font6 { font:11.00pt "Trebuchet MS", sans-serif; } .font7 { font:12.00pt "Trebuchet MS", sans-serif; } .font8 { font:15.00pt "Trebuchet MS", sans-serif; } .font9 { font:36.00pt "Trebuchet MS", sans-serif; } Spcifications...

 Open the catalog to page 2

All Wayne Combustion Systems catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.