1. Catalogs
  2. WayCon Positionsmesstechnik GmbH
  3. Ultrasonic Sensors UPR-A ATEX

Ultrasonic Sensors UPR-A ATEX

Ultrasonic Sensors UPR-A ATEX

Ultrasonic Sensors UPR-A ATEX

Product catalog summary
Key Features:
  • Measurement range: 120 to 1500 mm.
  • Suitable for hazardous areas (ATEX zone 22 for dust, zone 2 for gas).
  • Complies with directive 2014/34/EU and EN 60079:2012.
  • Functions as a distance sensor or 1-point proximity switch.
  • Teachable measurement range with linearity <1% of full scale.
  • Operating temperature: 0 to +60 °C, IP67 protection class.
  • Configurable sound cone size, optional synchronization.
Technical Data:
  • Models: UPR-A-1500-TOR-24-CAI-Ex, UPR-A-1500-TVPA-24-C-Ex.
  • Linearity: <1% MB, resolution: approx. 0.5 mm.
  • Output: 0...10 V or 4...20 mA, PNP NO/NC.
  • Supply voltage: 11...30 VDC, average power consumption: approx. 45...65 mA.
  • Protection: Reverse polarity protection, short circuit protection (model dependent).
Settings:
  • Switching points set via voltage supply to Teach input.
  • Analog output measuring limits set similarly, with LED indicators for detection status.
Synchronization & Suppression:
  • Sensors can be synchronized by interconnecting Teach/Sync wires.
  • Suppression mode stops sensor transmission with external signal.
Installation & Electrical Connection:
  • Mount with included M18 nuts, washers, and rubber sleeves.
  • Electrical connection via M12 connector, avoid parallel mounting with high current cables.
Influences on Measurement:
  • Environmental factors like rain, dust, and wind can affect accuracy.
  • Target characteristics such as material type and surface structure influence detection.
Models & Accessories:
  • Various models with analog or switching outputs, with or without synchronization.
  • Accessories include cables, connectors, and digital displays.
Safety Instructions:
  • Not for use as safety or emergency shut-off devices.
  • Ensure proper earthing and follow specified temperature and pressure ranges.
See more

Catalog excerpts

Ultrasonic Sensors UPR-A ATEX-1

Series UPR-A ATEX Key-Features: - Measurement range 120 to 1500 mm - For use in hazardous areas with dust (ATEX zone 22) and gas (ATEXzone 2) - Complies with the directive 2014/34/EU - In compliance with EN 60079:2012 - Distance sensor or 1-point proximity switch - Teachable measurement range - Linearity <1 % of full scale - With mechanical reinforcements on the front and connector side - Operating temperature 0 to +60 °C - Protection class IP67, waterproof, oil-resistant - Configurable size of sound cone - Optional with synchronisation

 Open the catalog to page 1
Ultrasonic Sensors UPR-A ATEX-2

TECHNICAL DATA UPR-A-1500-TOR-24-CAI-Ex Measurement range Linearity Linearity over full temperature range Hysteresis of switching point, axial Operating frequency Output speed analog output Average power consumption Ripple of supply voltage Reverse polarity protection Short circuit protection Protection class Operating temperature Pressure area Housing material nickel plated brass Status indicator ATEX designation The accuracy can be improved beyond by teaching the sensor only after it has reached its thermally stable state (e.g. after 30 minutes). The analog sensor automatically recognises the...

 Open the catalog to page 2
Ultrasonic Sensors UPR-A ATEX-3

In scanning mode, the target reflects a portion of the ultrasound, which in turn is detected by the sensor. The switching points are set by attaching the voltage supply -UB (0 V) or +UB (+24 VDC) during 1...5 s to the Teach input. The two measuring limits are set by attaching the voltage supply -UB (0 V) or +UB (+24 VDC) to the Teach input for 1...5 s. During the teaching process the flashing LED indicates if the sensor detected the target: • Yellow flashing LED: detected The lower evaluation limit (0 V or 4 mA) can be taught with -UB and the upper evaluation limit (10 V or 20 mA) with +UB. It...

 Open the catalog to page 3
Ultrasonic Sensors UPR-A ATEX-4

Ultrasonic sensor of the UPR-A ATEX series with option Y have the following two additional functions: Synchronisation: If several sensors are placed close together and scan the same object or if a common background is present, the sensors must be synchronized. For this, the Teach/Sync. wires of all sensors (max. 6 sensors) are interconnected. Important is the order: 1. teach each sensor individually (!) 3. interconnect all Teach/Sync. wires 4. power on again only when everything is wired! Suppression mode: This additional function is interesting, for example, in level measurement with troublesome...

 Open the catalog to page 4
Ultrasonic Sensors UPR-A ATEX-5

Environmental Influences Ultrasonic sensors are made for the use in atmospheric air. Environmental Influences like rain, snow, dust or smoke have influence on the accuracy of the measurement. However, measurements under pressure (higher that the atmospheric pressure) are not possible with ultrasound sensors. Strong wind or air turbulences may lead to instability in measurement values. A flow speed up to a few m/s is unproblematic and will have no influence on the sensor's accuracy. Target Influences • Liquids are excellently detectable with ultrasound. A classic application for ultrasonic sensors...