Series PAXP, PAXDP Key-Features: -1 channel model PAXP and 2 channel model PAXDP - 5 digits, 14 mm high LEDs, annunciators - Input signal 4...20 mA and 0...10 VDC - 20 measurements/s (PAXP) - 5.3 to 105.3 measurements/s, selectable (PAXDP) - 2, resp. 3 programmable user inputs - Protection class IP65 - Working temperature 0 to 50 °C, - Easy programming directly, or via PC - Plug-in output-cards: analog, USB, Relay (thresholds), Transistor, RS232, Profibus - Summation, min-/max value display - 16 point scaling - two galvanically isolated input channels (PAXDP)
Open the catalog to page 1TECHNICAL DATA Display Panel cut-out 5 digits, 14 mm high, red LEDs [mm] Annunciators PAXP MAX, MIN, TOT (sum), SP1, SP2, SP3, SP4 (the respective output SP is active) Annunciators PAXDP A, B, C (respective programmable display of the channel), SP1, SP2, SP3, SP4 (the respective output is active) Programmable user inputs Sensor inputs PAXP 3 (PAXP), 2 (PAXDP), logic state: jumper selectable for sink/source logic 20 (-2 to 26), accuracy (18-28 °C): 0.03% of reading, display resolution 1 µA 10 (-1 to 13), accuracy (18-28 °C): 0.03% of reading, display resolution 1 mV 20 (-26 to 26), accuracy...
Open the catalog to page 2TECHNICAL DRAWING PAXP, PAXDP optional custom units overlay Display readout legends Setpoint alarm annunciators ELECTRICAL CONNECTION PAXP Assignment PAXP 1 Voltage signal Current signal USER COMM. USER COMM. Connections PAXP Caution: Sensor input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the sensor input common must be suitably isolated from hazardous live earth referenced voltages; or input common must be at protective earth ground potential. If not, hazardous live voltage may be present at the User Inputs and User Input...
Open the catalog to page 3ELECTRICAL CONNECTION PAXDP Assignment PAXDP 1 Sensor supply channel A Input Jumpers These jumpers are used to select the proper input types, Voltage (V) or Current (I). The input type selected in programming must match the jumper setting. Sensor supply channel B Setting the Jumpers The meter has three jumpers that must be checked and/or changed prior to applying power. To access the jumpers, remove the meter base from the case by firmly squeezing and pulling back on the side rear finger tabs. This should lower the latch below the case slot (which is located just in front of the finger...
Open the catalog to page 4PLUG-IN CARDS The display can be fitted with up to three optional plug-in cards. The details for each plug-in card can be reviewed in the specification section below. Only one card from each function type can be installed at one time. The plug-in cards can be installed initially or at a later date. Analog Output Card (retransmitted linear DC output): PAXCDL10 ● Isolation to sensor + user input commons: 500 Vrms for 1 min., working range 50V, not isolated from all other commons. Accuracy: 0.17 % of FS (10 to 28 degree Celsius), 0.4% (0 to 50 degree Celsius) Compliance: 10 VDC, 10 kOhm load...
Open the catalog to page 5PROGRAMMING Directly by the displays keys DISPLAY MODE: The meter normally operates in the Display Mode. In this mode, the meter displays can be viewed consecutively by pressing the DSP key. The annunciators to the left of the display indicate which display is currently shown; Max Value (MAX), Min Value (MIN), or Totalizer Value (TOT). Each of these displays can be locked from view through programming. (See Module 3) The Input Display Value is shown with no annunciator. PROGRAMMING MODE: Two programming modes are available: Full Programming Mode permits all parameters to be viewed and...
Open the catalog to page 6PAXP0000 Voltage supply: 85 to 250 VAC PAXDP000 Voltage supply: 85 to 250 VAC PAXP0010 Voltage supply: 11 to 36 VDC/24 VAC PAXDP010 Voltage supply: 11 to 36 VDC/24 VAC Plug-in cards PAXCDC10 Serial communication card RS485 PAXCDC20 Serial communication card RS232, terminal PAXCDC50 Interface card PROFIBUS-DP PAXCDL10 Analog output card PAXCDS10 Dual relay, Form-C, normally open & closed PAXCDS20 Quad relay, Form-A, normally open only Software Crimson 2 on request Packages SFCRUSB1 includes USB plug-in card PAXUSB00 USB interface cable Software Crimson 2 Miscellaneous Housings PAXLBK11 Units...
Open the catalog to page 7All WayCon Positionsmesstechnik GmbH catalogs and technical brochures
-
LVIG SERIES
5 Pages
-
LAS2-TM SERIES
3 Pages
-
LASER SENSORS
8 Pages
-
Linear potentiometers
4 Pages
-
Magnetostrictive transducers
4 Pages
-
Ultrasonic sensors
4 Pages
-
Hydraulic sensors
4 Pages
-
Product overview
12 Pages
-
Capacitive Sensor KS
9 Pages
-
LX Compact Sensor
6 Pages
-
SX300 Hydraulic transducer
8 Pages
-
Linear Potentiometer LMS18
4 Pages
-
Linear Potentiometer LSW
4 Pages
-
Linear Potentiometer LZW2-IP
4 Pages
-
B36 Incremental Encoder
5 Pages
-
SSI Absolute Encoder
9 Pages
-
Profinet Absolute Encoder
6 Pages
-
Laser Sensor LAS-T5
5 Pages
-
Laser Sensor LAM
9 Pages
-
Linear Potentiometer LZW
6 Pages
-
Ultrasonic Sensors UFP, UPA
7 Pages
-
CANopen Absolute Encoder
12 Pages
-
Profibus Absolute Encoder
6 Pages
-
EtherCAT Absolute Encoder
6 Pages
-
Analog Rotary Sensor WP
8 Pages
-
Draw wire sensor HX
10 Pages
-
Long Distance Laser LLD-150
5 Pages
-
Laser Sensor LAV
5 Pages
-
Linear Potentiometer LZW2
4 Pages
-
Linear Potentiometer LZW1
4 Pages
-
Linear Potentiometer LRW1
4 Pages
-
Analog Absolute Encoder M36
7 Pages
-
Laser sensors LAR
4 Pages
-
Draw Wire Sensor SX50
13 Pages
-
Draw Wire Sensor SX80
14 Pages
-
Draw Wire Sensor SX120
14 Pages
-
Linear Potentiometer LRW
5 Pages
-
Hydraulic Transducer SX200
6 Pages
-
Digital Length Gauges
5 Pages
-
Digital Scale DMO
3 Pages
-
Draw Wire Sensor MH120
11 Pages
-
Draw Wire Sensors MH60
9 Pages
-
Draw Wire Sensor FX-HM
4 Pages
-
Draw Wire Sensor ZX
3 Pages
-
Laser Sensor LAH-G1
4 Pages
-
VTS-Box Teach Electronic
3 Pages
-
Analog Magnetic Scales MXAZ
4 Pages
-
Digital Magnetic Scale MXS2
4 Pages
-
SSI Absolut Encoder F36
7 Pages
-
Signal Conditioner PMX-24
4 Pages
-
Analog Absolut Encoder M58
5 Pages
-
Draw wire sensors
8 Pages