Catalog excerpts
Technical Data Technical Drawing Electrical Connection Plug-In Cards Programming & Software Order Code & Accessories
Open the catalog to page 1TECHNICAL DATA PAXD Display 5 digits, 14 mm high, red LEDs Panel cut-out MAX, MIN, TOT (sum), SP1, SP2, SP3, SP4 (the respective output SP is active) Programmable user inputs 3, logic state: jumper selectable for sink/source logic PNP: active V in >3.6 VDC, inactive V in <0.9 VDC, NPN: active V in <0.9 VDC, inactive V in >3.6 VDC Input signal Output signal (via plug-in cards) Relay output, transistor output, analog output Serial Interfaces (via plug-in cards) USB port (programmable), RS485, RS232, Profibus Update rate 200 ms to within 99% of final readout value, max. 700 ms Supply voltage...
Open the catalog to page 2Caution: Sensor input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the sensor input common must be suitably isolated from hazardous live earth referenced voltages. JUMPER SETTINGS Before putting the meter into operation the jumper settings have to be checked and if needed adjusted The following points have to be set by the jumpers: • Input range jumper (factory setting +/-300 V) • Excitation output jumper (factory setting 24 V) • User input logic jumper (factory setting NPN) INPUT RANGE JUMPER ^EXCITATION OUTPUT JUMPER^ ONLY ONE...
Open the catalog to page 3PLUG-IN CARDS The display can be fitted with up to three optional plug-in cards. The details for each plug-in card can be reviewed in the specification section below. Only one card from each function type can be installed at one time. The plug-in cards can be installed initially or at a later date. Analog Output Card (retransmitted linear DC output): PAXCDL10 ● Isolation to sensor + user input commons: 500 Vrms for 1 min., working range 50V, not isolated from all other commons. Accuracy: 0.17 % of FS (10 to 28 degree Celsius), 0.4% (0 to 50 degree Celsius) Compliance: 10 VDC, 10 kOhm load...
Open the catalog to page 4PROGRAMMING Directly by the display keys DISPLAY MODE: The meter normally operates in the Display Mode. In this mode, the meter displays can be viewed consecutively by pressing the DSP key. The annunciators to the left of the display indicate which display is currently shown; Max Value (MAX), Min Value (MIN), or Totalizer Value (TOT). Each of these displays can be locked from view through programming. (See Module 3) The Input Display Value is shown with no annunciator. PROGRAMMING MODE: Two programming modes are available: Full Programming Mode permits all parameters to be viewed and...
Open the catalog to page 5PAXD0000 Voltage supply: 85 to 250 VAC PAXD0010 Voltage supply: 11 to 36 VDC/24 VAC Plug-in cards PAXCDC10 Serial communication card RS485 PAXCDC20 Serial communication card RS232, terminal PAXCDC50 Interface card PROFIBUS-DP PAXCDL10 Analog output card PAXCDS10 Dual relay, Form-C, normally open & closed PAXCDS20 Quad relay, Form-A, normally open only Software Crimson 2 on request Packages SFCRUSB1 includes USB plug-in card PAXUSB00 USB interface cable Software Crimson 2 Miscellaneous Housings PAXLBK10 Units label kit GEH0IP65 Aluminium housing, IP65 Einstellung Pre-adjustment according to...
Open the catalog to page 6All WayCon Positionsmesstechnik GmbH catalogs and technical brochures
-
LVIG SERIES
5 Pages
-
LAS2-TM SERIES
3 Pages
-
LASER SENSORS
8 Pages
-
Linear potentiometers
4 Pages
-
Magnetostrictive transducers
4 Pages
-
Ultrasonic sensors
4 Pages
-
Hydraulic sensors
4 Pages
-
Product overview
12 Pages
-
Capacitive Sensor KS
9 Pages
-
LX Compact Sensor
6 Pages
-
SX300 Hydraulic transducer
8 Pages
-
Linear Potentiometer LMS18
4 Pages
-
Linear Potentiometer LSW
4 Pages
-
Linear Potentiometer LZW2-IP
4 Pages
-
B36 Incremental Encoder
5 Pages
-
SSI Absolute Encoder
9 Pages
-
Profinet Absolute Encoder
6 Pages
-
Laser Sensor LAS-T5
5 Pages
-
Laser Sensor LAM
9 Pages
-
Linear Potentiometer LZW
6 Pages
-
Ultrasonic Sensors UFP, UPA
7 Pages
-
CANopen Absolute Encoder
12 Pages
-
Profibus Absolute Encoder
6 Pages
-
EtherCAT Absolute Encoder
6 Pages
-
Analog Rotary Sensor WP
8 Pages
-
Draw wire sensor HX
10 Pages
-
Long Distance Laser LLD-150
5 Pages
-
Laser Sensor LAV
5 Pages
-
Linear Potentiometer LZW2
4 Pages
-
Linear Potentiometer LZW1
4 Pages
-
Linear Potentiometer LRW1
4 Pages
-
Analog Absolute Encoder M36
7 Pages
-
Laser sensors LAR
4 Pages
-
Draw Wire Sensor SX50
13 Pages
-
Draw Wire Sensor SX80
14 Pages
-
Draw Wire Sensor SX120
14 Pages
-
Linear Potentiometer LRW
5 Pages
-
Hydraulic Transducer SX200
6 Pages
-
Digital Length Gauges
5 Pages
-
Digital Scale DMO
3 Pages
-
Draw Wire Sensor MH120
11 Pages
-
Draw Wire Sensors MH60
9 Pages
-
Draw Wire Sensor FX-HM
4 Pages
-
Draw Wire Sensor ZX
3 Pages
-
Laser Sensor LAH-G1
4 Pages
-
VTS-Box Teach Electronic
3 Pages
-
Analog Magnetic Scales MXAZ
4 Pages
-
Digital Magnetic Scale MXS2
4 Pages
-
SSI Absolut Encoder F36
7 Pages
-
Signal Conditioner PMX-24
4 Pages
-
Analog Absolut Encoder M58
5 Pages
-
Draw wire sensors
8 Pages