1. Catalogs
  2. WayCon Positionsmesstechnik GmbH
  3. Long Distance Laser LLD-150

Long Distance Laser LLD-150

Long Distance Laser LLD-150

Long Distance Laser LLD-150

Product catalog summary
Key Features:
  • Measurement range: 0.1 to 150 m
  • Resolution: up to 0.1 mm
  • Repeatability: ±0.5 mm
  • Linearity: up to ±2 mm
  • Protection class: IP65
  • Operating temperature: -10 to +50 °C, optional -40 to +50 °C
  • Measurement frequency: up to 50 Hz
  • Outputs: Analog (4...20 mA), Digital (RS232, RS422, Profibus, SSI)
Technical Data:
  • Measurement range: 0.1...30 m on natural surfaces, 0.1...150 m on reflecting foil
  • Linearity: ±2 mm on white surfaces, ±3 mm on natural surfaces, ±5 mm at -10...+50 °C
  • Resolution: 0.1 mm
  • Repeatability: ≤0.5 mm
  • Measurement frequency: 10 to 50 Hz
  • Light source: Laser diode, red, 650 nm
  • Laser class: Class 2, EN 60825-1:2014
  • Power supply: 10...30 VDC
  • Protection class: IP65
  • Operating temperature: -10...+50 °C (optional heating for -40...+50 °C)
  • Weight: 760-770 g
Getting Started:

Initial setup requires configuring the autostart function and scaling the measurement range for the analog output. The WayCon configuration software facilitates these settings.

Types of Output:
  • Analog output: 4...20 mA, proportional to distance
  • RS232 output: Suitable for short distances, max 38.4 kBaud
  • RS422 output: Differential interface for long distances, requires RS422 interface card or converter
  • Profibus output: Plug-and-play for fieldbus applications, max 12 Mbaud
  • SSI output: Synchronous interface, 24 bit, 1 MHz max
  • Digital switching output: Allows supervision of targets with preset thresholds
Scope of Delivery:
  • Sensor LLD-150
  • Manual
  • WayCon LLD-configuration software CD
Configuration Software:

Users can select operational modes via terminal programs or the WayCon software interface. RS232/RS422 sensors require a converter for RS422 interfaces.

Factory Setting:

WayCon offers pre-configuration for RS232/RS422 sensors, allowing immediate use after unpacking.

General Safety:
  • Avoid staring into the laser beam
  • Use matte objects to stop the beam
  • Switch off power when not in use
Order Code and Accessories:

Various cables and connectors are available for different output versions, including RS232/RS422 and Profibus/SSI.

See more

Catalog excerpts

Long Distance Laser LLD-150-1

- Measurement range from 0.1 up to 150 m - Resolution up to 0.1 mm - Repeatability: ±0.5 mm - Linearity up to ±2 mm - Protection class IP65 - Operating temperature: -10 to +50 °C, optional -40 to +50 °C - Measurement frequency up to 50 Hz - Analog output: 4...20 mA - Digital output: RS232, RS422, Profibus, SSI

 Open the catalog to page 1
Long Distance Laser LLD-150-3

GETTING STARTED For initial operation, the sensor has to be set into operation mode, i.e. the autostart function must be configured. This function decides on the mode generally to be activated after switching on. Single point and continuous measurement (distance tracking) in different modes are available. Before using the analog output, the measurement range must be scaled: 4 mA is assigned to the minimum, 20 mA to the maximum measurement range. All these settings are quickly performed by means of the WayCon configuration software included in the delivery. TYPES OF OUTPUT Analog output 4...20...

 Open the catalog to page 3
Long Distance Laser LLD-150-4

CONFIGURATION SOFTWARE Before starting to work with the LLD-Sensor, the user has to select the operational mode, either via a terminal program (like „Hyperterminal“) or by performing the configuration by means of the conveniently designed user interface of the WayCon software, available in English language. The latter choice uses the serial interface and is therefore possible only for the RS232 or RS422 LLD-Laser sensors (not for the Profibus, SSI version). Please be aware that normal PC’s and Laptops do not have a RS422 interface and hence a RS422/RS232 converter is required. When establishing...

 Open the catalog to page 4
Long Distance Laser LLD-150-5

ACCESSORIES General accessories ZT51_WEISS target board for measurement ranges >30 m 3M 3279 special reflecting foil for measurement ranges >30 m Accessories RS232/RS422-Version KAB-LLD-2M Interface cable 2 m, female, straight KAB-LLD-5M Interface cable 5 m, female, straight KAB-LLD-10M Interface cable 10 m, female, straight 94477 Mating connector M16, female, straight LLD-Aktivierung Pre-configuration of RS232/RS422 version Accessories Profibus/SSI-Version KAB-LLD500-2M-S Power supply cable 2 m, female, straight KAB-LLD500-5M-S Power supply cable 5 m, female, straight KAB-LLD500-10M-S Power...