1. Catalogs
  2. WayCon Positionsmesstechnik GmbH
  3. Linear Potentiometer LZW2-IP

Linear Potentiometer LZW2-IP

Linear Potentiometer LZW2-IP

Linear Potentiometer LZW2-IP

Product catalog summary
Key Features:
  • Protection class IP67
  • Housing diameter of 19 mm
  • Flexible mounting options with brackets or rod end bearings
  • Measurement ranges available from 25 to 300 mm
  • Displacement speed up to 3 m/s
  • Linearity up to ±0.05%
  • Operating temperature range from -30 to +100 °C
  • Life cycle exceeding 25 million meters or 100 million operations
  • Complies with EN 60079-11 standard
Technical Data:
  • Measurement range options: 25 to 300 mm
  • Electrical stroke matches measurement range
  • Resistance varies from 1 to 12 kOhm depending on range
  • Linearity ranges from 0.2% to 0.05%
  • Maximum power supply of 60V
  • Mechanical stroke is 5 mm longer than electrical stroke
  • Case length varies with model and measurement range
Installation Instructions:
  • Do not use the sensor as a variable resistor
  • Calibrate to ensure output signal remains between 1% and 99% of voltage level
  • Lubricate sliding parts every 6 months
Electrical Connection:
  • Signal conditioner PMX-24 converts potentiometer signals to analog outputs
  • Various cable and connector options available, including M8 and M12 connectors
Order Code and Accessories:
  • Order codes vary based on measurement range and mounting type
  • Accessories include cables, connectors, and mounting hardware
See more

Catalog excerpts

Linear Potentiometer LZW2-IP-1

LZW2-IP Series Content: Technical Data Electrical Connection Technical Drawing Order Code Accessories - Simple apparatus according to the EN 60079-11 standard

 Open the catalog to page 1
Linear Potentiometer LZW2-IP-2

TECHNICAL DATA Measurement range Protection class Displacement speed Resolution depends on the signal quality of the ref erence v oltage respectiv ely supply v oltage. Recommended cursor current Maximum cursor current Temperature coef f icient of the output v oltage Electrical isolation Dielectric strength Working temperature Storage temperature Housing material anodised aluminium LZW2-S-IP with brackets, LZW2-A-IP with rod end bearings ABMESSUNGEN UND ELEKTRISCHE DATEN DIMENSIONS AND ELECTRICAL DATA Measurement range Theoretical electrical Stroke (C) ±1 Maximum power supply Minimum distance...

 Open the catalog to page 2
Linear Potentiometer LZW2-IP-3

Cable with connector M12, 4 pole, shielded IP67 K4P2M-S-M12 2 m, connector, straight Connector M12, 4 pole, IP67, shielded D4-G-M12-S connector, straight, (self assembly) D4-W-M12-S connector, angular, (self assembly) Signal conditioner PMX-24 • Converts potentiometer signals into analog output signals (4...20 mA, 0...10 V, 0...5 V, ±10 V, ±5 V) • Input: potentiometer 1...20 kO • Configurable output • DIN-rail-mounting with face-side connector • For further information please contact WayCon or download the data sheet. LZW2-S-IP: installation with brackets

 Open the catalog to page 3
Linear Potentiometer LZW2-IP-4

Cable with connector M8, IP67, 3 pole, for LZW2-A-IP K3P2M-S-M8 2 m, straight connector, shielded K3P5M-S-M8 5 m, straight connector, shielded Cable with connector M12, IP67, 4 pole, for LZW2-S-IP K4P2M-S-M12 2 m, connector, straight, shielded K4P5M-S-M12 5 m, connector, straight, shielded K3P10M-S-M8 10 m, straight connector, shielded K4P10M-S-M12 10 m, connector, straight, shielded Rod end bearing for LZW2-S-IP (included in delivery) Bracket for LZW2-S-IP (included in delivery) SND019 M8 external thread, stainless steel STA075 1 bracket Signal Conditioner PMX-24 different analog output signals...

 Open the catalog to page 4

All WayCon Positionsmesstechnik GmbH catalogs and technical brochures

  1. LVIG SERIES

    5  Pages

  2. LASER SENSORS

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.