1. Catalogs
  2. WayCon Positionsmesstechnik GmbH
  3. Linear Potentiometer LMI12/LME12

Linear Potentiometer LMI12/LME12
1 /4Pages

Linear Potentiometer LMI12/LME12

Linear Potentiometer LMI12/LME12
1 /4Pages

Catalog excerpts

Linear Potentiometer LMI12/LME12-1

Content: Technical Data Technical Drawing Order Code Accessories Series LME12 and LMI12 Key-Features: - Linear displacement transducer with magnetic cursor drag 2 - Suitable for harsh environment applications (IP67) 4 - Measurement ranges from 50 up to 1000 mm - Displacement speed <5 m/s - Linearity up to ±0.05 % - Working temperature -30...+ 100 °C - Life cycle >25 x 106 meter or 100x 106 operations, whichever is less - Simple apparatus according to the EN 60079-11 standard

 Open the catalog to page 1
Linear Potentiometer LMI12/LME12-2

TECHNICAL DATA LME12 Measurement range Measurement ranges up to 100 mm: ±0.1 Measurement ranges above 150 mm: ±0.05 depends on the signal quality of the reference voltage respectively supply voltage Displacement sensitivity Cursor dragging force Displacement speed Measurement ranges up to 300 mm: 5 Measurement ranges 350 to 600 mm: 10 Measurement ranges above 650 mm: 20 Measurement range 50 mm: 1 Measurement range 100 mm: 2 Measurement ranges above 150 mm: 3 Measurement range 50 mm: 40 Measurement ranges above 100 mm: 60 Recommended cursor current Cursor current in case of bad performances max....

 Open the catalog to page 2
Linear Potentiometer LMI12/LME12-3

3-core PUR cable, shielded — length 1 m, a4 mm Bracket STA001 for LME12 (2 pcs. included in delivery)

 Open the catalog to page 3
Linear Potentiometer LMI12/LME12-4

Sensor is to be used as voltage divider only, using a maximum cursor current of Ic < 0.1 gA. Do NOT use the sensor as variable resistance! When calibrating the transducer, be careful to set the stroke so that the output does not drop below 1% or rise above 99% of the voltage level. Scope of delivery: LME12: Sensor, 2 brackets STA001, 1 magnetic cursor PCUR0321 LMI12: Sensor, 1 magnetic cursor PCUR032 PCUR032 1 magnetic cursor for LMI12 For more information and options please refer to the WAY-AX data sheet. Signal conditioner PMX-24 Output signals: 4...20 mA, 0...10 V, 0...5 V, ±10 V, ±5 V For...