Catalog excerpts
Technical Data Technical Drawing Electrical Connection Plug-in Cards Programming & Software Order Code & Accessories
Open the catalog to page 1TECHNICAL DATA PAXI Display 6 digits, 14 mm high, red LEDs Panel cut-out A, B, C (counter), SP1, SP2, SP3, SP4 (the respective output is active) Programmable user inputs 3, logic state: jumper selectable for sink/source logic PNP: active V in >2.4 VDC, inactive Vin <0.9 VDC, NPN: active V in <0.9 VDC, inactive V in >2.4 VDC Input signal incremental sensors with TTL signal, NPN and PNP sensors (settings by DIP switches) Output signal (via plug-in cards) Relay output, transistor output, analog output Serial Interfaces (via plug-in cards) USB port (programmable), RS485, RS232, Profibus...
Open the catalog to page 2ELECTRICAL CONNECTION PAXI Assignment PAXI 1 Prescaler output, NPN,O.C. Caution: Sensor input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the sensor input common must be suitably isolated from hazardous live earth referenced voltages; or input common must be at protective earth ground potential. If not, hazardous live voltage may be present at the User Inputs and User Input Common terminals. Appropriate considerations must then be given to the potential of the user input common with respect to earth common; and the common of the...
Open the catalog to page 3PLUG-IN CARDS The display can be fitted with up to three optional plug-in cards. The details for each plug-in card can be reviewed in the specification section below. Only one card from each function type can be installed at one time. The plug-in cards can be installed initially or at a later date. Analog Output Card (retransmitted linear DC output): PAXCDL10 ● Isolation to sensor + user input commons: 500 Vrms for 1 min., working range 50V, not isolated from all other commons. Accuracy: 0.17 % of FS (10 to 28 degree Celsius), 0.4% (0 to 50 degree Celsius) Compliance: 10 VDC, 10 kOhm load...
Open the catalog to page 4PROGRAMMING Directly by the displays keys The meter normally operates in the Display Mode. No parameters can be programmed in this mode. The Programming Mode is entered by pressing the PAR key. If it is not accessible then it is locked by either a security code, or a hardware lock. Two types of programming modes are available. Quick Programming Mode permits only certain parameters to be viewed and/or modified. All meter functions continue to operate except the front panel keys change to Programming Mode Operations. Quick Programming Mode is configured in Module 3. Full Programming Mode...
Open the catalog to page 5Plug-in cards PAXCDC10 Serial communication card RS485 PAXCDC20 Serial communication card RS232, terminal PAXCDC50 Interface card PROFIBUS-DP PAXCDL10 Analog output card PAXCDS10 Dual relay, Form-C, normally open & closed PAXCDS20 Quad relay, Form-A, normally open only Software Crimson 2 on request Packages SFCRUSB1 includes USB plug-in card PAXUSB00 USB interface cable Software Crimson 2 Miscellaneous Housings PAXLBK10 Units label kit GEH0IP65 Aluminium housing, IP65 Einstellung Pre-adjustment according to customer demands TG9648 Table housing Subject to change without prior notice. WayCon...
Open the catalog to page 6All WayCon Positionsmesstechnik GmbH catalogs and technical brochures
-
LVIG SERIES
5 Pages
-
LAS2-TM SERIES
3 Pages
-
LASER SENSORS
8 Pages
-
Linear potentiometers
4 Pages
-
Magnetostrictive transducers
4 Pages
-
Ultrasonic sensors
4 Pages
-
Hydraulic sensors
4 Pages
-
Product overview
12 Pages
-
Capacitive Sensor KS
9 Pages
-
LX Compact Sensor
6 Pages
-
SX300 Hydraulic transducer
8 Pages
-
Linear Potentiometer LMS18
4 Pages
-
Linear Potentiometer LSW
4 Pages
-
Linear Potentiometer LZW2-IP
4 Pages
-
B36 Incremental Encoder
5 Pages
-
SSI Absolute Encoder
9 Pages
-
Profinet Absolute Encoder
6 Pages
-
Laser Sensor LAS-T5
5 Pages
-
Laser Sensor LAM
9 Pages
-
Linear Potentiometer LZW
6 Pages
-
Ultrasonic Sensors UFP, UPA
7 Pages
-
CANopen Absolute Encoder
12 Pages
-
Profibus Absolute Encoder
6 Pages
-
EtherCAT Absolute Encoder
6 Pages
-
Analog Rotary Sensor WP
8 Pages
-
Draw wire sensor HX
10 Pages
-
Long Distance Laser LLD-150
5 Pages
-
Laser Sensor LAV
5 Pages
-
Linear Potentiometer LZW2
4 Pages
-
Linear Potentiometer LZW1
4 Pages
-
Linear Potentiometer LRW1
4 Pages
-
Analog Absolute Encoder M36
7 Pages
-
Laser sensors LAR
4 Pages
-
Draw Wire Sensor SX50
13 Pages
-
Draw Wire Sensor SX80
14 Pages
-
Draw Wire Sensor SX120
14 Pages
-
Linear Potentiometer LRW
5 Pages
-
Hydraulic Transducer SX200
6 Pages
-
Digital Length Gauges
5 Pages
-
Digital Scale DMO
3 Pages
-
Draw Wire Sensor MH120
11 Pages
-
Draw Wire Sensors MH60
9 Pages
-
Draw Wire Sensor FX-HM
4 Pages
-
Draw Wire Sensor ZX
3 Pages
-
Laser Sensor LAH-G1
4 Pages
-
VTS-Box Teach Electronic
3 Pages
-
Analog Magnetic Scales MXAZ
4 Pages
-
Digital Magnetic Scale MXS2
4 Pages
-
SSI Absolut Encoder F36
7 Pages
-
Signal Conditioner PMX-24
4 Pages
-
Analog Absolut Encoder M58
5 Pages
-
Draw wire sensors
8 Pages