1. Catalogs
  2. WayCon Positionsmesstechnik GmbH
  3. Display Control PAXI for incremental signal

Display Control PAXI for incremental signal

Display Control PAXI for incremental signal

Display Control PAXI for incremental signal

Product catalog summary
Key Features:
  • 6-digit, 14 mm high LED display with annunciators.
  • Two independent inputs supporting TTL, NPN, and PNP sensors.
  • Maximum measurement frequency of 34 kHz.
  • Three programmable user inputs and IP65 protection class.
  • Operating temperature range from 0 to 50°C.
  • Easy programming via direct input or PC.
  • Supports plug-in output cards including analog, USB, relay, transistor, RS232, and Profibus.
  • Features summation and min/max value display with 10-point scaling for non-linear processes.
Technical Data:
  • Display: 6 digits, 14 mm high, red LEDs.
  • Panel cut-out: 92 mm x 45 mm.
  • Input signals: Incremental sensors with TTL, NPN, and PNP settings via DIP switches.
  • Output signals and serial interfaces available via plug-in cards.
  • Supply voltage options: 11-36 VDC/24 VAC or 85-250 VAC.
  • Protection class: IP65 (face only).
  • Working temperature: 0 to 50°C, with plug-in cards: 0 to 45°C.
  • Conforms to CE, EN 50081-2, EN50082-2 standards.
Electrical Connection:
  • Power supply options for AC and DC.
  • Sensor supply: 12 VDC/100 mA.
  • Various user inputs and prescaler output configurations.
Plug-in Cards:
  • Analog Output Card: Types include 0 to 20 mA, 4 to 20 mA, or 0 to 10 VDC.
  • Setpoint Alarm Output Cards: Options for sourcing and sinking open collector cards, and relay cards.
  • Interface Cards: RS232, RS485, DeviceNet, Profibus-DP, and USB options available.
Programming:
  • Direct programming via display keys or through PC using Crimson software.
  • Two programming modes: Quick and Full Programming Mode.
  • Remote control possible with RS232 or RS485 cards.
Order Code & Accessories:
  • Various voltage supply options and plug-in cards available.
  • Accessories include USB interface cable and Crimson software.
See more

Catalog excerpts

Display Control PAXI for incremental signal-1

Technical Data Technical Drawing Electrical Connection Plug-in Cards Programming & Software Order Code & Accessories

 Open the catalog to page 1
Display Control PAXI for incremental signal-2

TECHNICAL DATA PAXI Display 6 digits, 14 mm high, red LEDs Panel cut-out A, B, C (counter), SP1, SP2, SP3, SP4 (the respective output is active) Programmable user inputs 3, logic state: jumper selectable for sink/source logic PNP: active V in >2.4 VDC, inactive Vin <0.9 VDC, NPN: active V in <0.9 VDC, inactive V in >2.4 VDC Input signal incremental sensors with TTL signal, NPN and PNP sensors (settings by DIP switches) Output signal (via plug-in cards) Relay output, transistor output, analog output Serial Interfaces (via plug-in cards) USB port (programmable), RS485, RS232, Profibus Prescaler...

 Open the catalog to page 2
Display Control PAXI for incremental signal-3

ELECTRICAL CONNECTION PAXI Assignment PAXI 1 Prescaler output, NPN,O.C. Caution: Sensor input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the sensor input common must be suitably isolated from hazardous live earth referenced voltages; or input common must be at protective earth ground potential. If not, hazardous live voltage may be present at the User Inputs and User Input Common terminals. Appropriate considerations must then be given to the potential of the user input common with respect to earth common; and the common of the isolated...

 Open the catalog to page 3
Display Control PAXI for incremental signal-4

PLUG-IN CARDS The display can be fitted with up to three optional plug-in cards. The details for each plug-in card can be reviewed in the specification section below. Only one card from each function type can be installed at one time. The plug-in cards can be installed initially or at a later date. Analog Output Card (retransmitted linear DC output): PAXCDL10 ● Isolation to sensor + user input commons: 500 Vrms for 1 min., working range 50V, not isolated from all other commons. Accuracy: 0.17 % of FS (10 to 28 degree Celsius), 0.4% (0 to 50 degree Celsius) Compliance: 10 VDC, 10 kOhm load min.,...

 Open the catalog to page 4
Display Control PAXI for incremental signal-5

PROGRAMMING Directly by the displays keys The meter normally operates in the Display Mode. No parameters can be programmed in this mode. The Programming Mode is entered by pressing the PAR key. If it is not accessible then it is locked by either a security code, or a hardware lock. Two types of programming modes are available. Quick Programming Mode permits only certain parameters to be viewed and/or modified. All meter functions continue to operate except the front panel keys change to Programming Mode Operations. Quick Programming Mode is configured in Module 3. Full Programming Mode permits...

 Open the catalog to page 5
Display Control PAXI for incremental signal-6

Plug-in cards PAXCDC10 Serial communication card RS485 PAXCDC20 Serial communication card RS232, terminal PAXCDC50 Interface card PROFIBUS-DP PAXCDL10 Analog output card PAXCDS10 Dual relay, Form-C, normally open & closed PAXCDS20 Quad relay, Form-A, normally open only Software Crimson 2 on request Packages SFCRUSB1 includes USB plug-in card PAXUSB00 USB interface cable Software Crimson 2 Miscellaneous Housings PAXLBK10 Units label kit GEH0IP65 Aluminium housing, IP65 Einstellung Pre-adjustment according to customer demands TG9648 Table housing Subject to change without prior notice. WayCon Positionsmesstechnik...