Overview: The WP400-3 Probe is designed for measuring electric and magnetic fields across a frequency range of 1 Hz to 400 kHz. It supports isotropic and true RMS measurements and is suitable for spectrum analysis in compliance with international standards.
Standards Compliance: The probe adheres to several international standards, including IEC/EN 62311, IEC/EN 62822, and IEC/EN 62233, ensuring safe assessment of electromagnetic fields in various equipment and environments.
Technical Specifications:
  • Frequency Range: 1 Hz – 400 kHz for both electric and magnetic fields.
  • Measurement Range: Electric field: 10 V/m to 400 kV/m; Magnetic field: 200 nT - 50 mT (100 Hz - 10 kHz).
  • Resolution: Electric field: < 4 mV/m above 8 Hz; Magnetic field: < 0.3 nT (at 50 Hz) and < 0.15 nT above 100 Hz.
  • Noise Level: Electric field: < 10 V/m (10 Hz - 400 kHz); Magnetic field: < 200 nT (10 Hz - 400 kHz).
  • Typical Uncertainty: 0.67 dB for electric fields and 0.60 dB for magnetic fields (10 Hz - 100 kHz).
Graphical Display: The probe provides real-time digital displays for RMS, axis values, AVG, MAX, MIN, PEAK, and RMS time graphs.
FFT Mode: Offers frequency analysis with a measurement range of 40 mV/m – 400 kV/m for electric fields and 2 nT - 50 mT for magnetic fields, with a noise level of < 40 mV/m and < 1.8 nT respectively.
General Specifications:
  • Isotropy: ± 5% for electric fields and ± 4% for magnetic fields.
  • Temperature Deviation: Varies slightly with temperature changes, with specific deviations noted for different temperature ranges.
  • Damage Level: Electric field: > 600 kV/m; Magnetic field: > 5000 mT up to 60 Hz, with damage level decreasing linearly with increasing frequency above 60 Hz.
  • Linearity: ± 1% (typical), ± 2% (maximum).
  • Weight and Size: 125 g; 275 x 33 mm Ø.
Additional Features: The probe supports easy software updates to accommodate future modifications and new limits.
See more

Catalog excerpts

WP400-3-1

Electric & Magnetic field measurement Isotropic & True RMS measurement Spectrum analysis probe Measurements in accordance with International Standards IEC/EN 62233 Household appliances and similar apparatus: Measurement methods for electromagnetic fields with regard to human exposure. IEC/EN 62822 Electric welding equipment: Assessment of restrictions related to human exposure to electromagnetic fields. IEC/EN 62311 Assessment of electronic and electrical equipment for which no dedicated product- or product family standard regarding human exposure to electromagnetic fields applies. Technical Specifications Safety, Quality, Service

 Open the catalog to page 1
WP400-3-2

(1) Total, counting isotropy, temperature deviation, resolution, frequency response, linearity, repeatability. Product specifications and descriptions in this document subject to change without notice Safety, Quality, Service

 Open the catalog to page 2

All WAVECONTROL catalogs and technical brochures

  1. MonitEM-Lab

    2  Pages

  2. WPH-DC Probe

    1  Page

  3. WP Wifi

    1  Page

  4. WPT

    1  Page

  5. WPH1000

    1  Page

  6. WPH60

    1  Page

  7. WPF40

    1  Page

  8. WPF18

    1  Page

  9. WPF8

    1  Page

  10. WPF6

    1  Page

  11. WPF3

    1  Page

  12. WP400

    2  Pages

  13. WP50

    1  Page

  14. SMP2

    2  Pages

  15. MapEM

    2  Pages

  16. MonitEM

    2  Pages

  17. cMonitEM

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.