Catalog excerpts
Tempering Solutions for ASSE 1070 Applications Whirlpools Lavatories Bidets
Open the catalog to page 1* ±3°F Union inlets for easy maintenance Temperature locking mechanism prevents unauthorized adjustment of set temperature Integral checks prevent cross-flow Integral screens keep debris away from the valve Advance thermal actuator provides near instantaneous response International Residential Code - 2006 Section P2713.3 Bathtub and Whirlpool Bathtub Valves “The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to 120ºF (49ºC) by a water temperature-limiting device that conforms to ASSE 1070, except where such protection is otherwise provided by a combination tub/shower...
Open the catalog to page 2USG-B Lavatory Valve I Pressure Drop deal for tempering water to sinks in public rest room facilities, the Under Sink Guardian features Watts’ patented “H” pattern design with an integral cold water bypass saving considerable time and money during installation. The Series USG is available in bronze (USG-B) construction and features integral checks to prevent cross flow and inlet screens to filter out debris. Precise temperature control ensures safe water delivery temperature at all times. International Plumbing Code - 2006 Section 416.5 Tempered water for public hand washing facilities...
Open the catalog to page 3Most Asked Questions on ASSE 1070 What is meant by water temperature limiting device? One that restricts or limits the maximum temperature of the hot water supplying a fixture/fitting(s). Simply put, it’s tempering the hot side of a valve in order to limit the maximum outlet temperature available to the user when mixed with cold water. What is the scope of ASSE 1070? What are the applications? ASSE 1070 is for devices that limit water temperature to a fixture or fixtures such as sinks, lavatories, or bathtubs to reduce the risk of scalding. It is not intended to provide protection from...
Open the catalog to page 4All Watts Water Technologies catalogs and technical brochures
-
Backflow Prevention
92 Pages
-
Hydronic Heating Specialties
60 Pages
-
WATTS.COM/CAD
1 Pages
-
Watts Flow Switch
2 Pages
-
Thermostatic Mixing Valves
12 Pages
-
Watts PRV Irrigation
1 Pages
-
Thermal Expansion Products
24 Pages
-
Water Pressure Reducing Valves
44 Pages
-
Flippen Float Valves
12 Pages
-
Ball Valves
28 Pages
-
Steam Pressure Regulators
8 Pages
-
Solar Solutions
20 Pages
-
OneFlow Model OFTWH
2 Pages
-
LavSafe Thermostatic Faucets
4 Pages
-
Series X65B
2 Pages
-
OneFlow® Anti-Scale Systems
2 Pages
-
Watts Boiler Header Module
4 Pages
-
Steam Products
24 Pages
-
008 PCQT
2 Pages
-
Series 17
1 Pages
-
Series 152SS
2 Pages
-
Series 152A
2 Pages
-
Series 150A
2 Pages
-
Series 1450F
1 Pages
-
Series 144
2 Pages
-
Series 142
2 Pages
-
Series 40, 140, 240 & 340
2 Pages
-
Model 127W
2 Pages
-
ES-127
2 Pages
-
Series 123LP
1 Pages
-
Series 1170 and L1170
2 Pages
-
Series 1156F
2 Pages
-
Series 1L, 1XL, 10L
2 Pages
-
Series 100DT
1 Pages
-
Series 05
2 Pages
-
Series 007
4 Pages
-
Flow-Max Filters
4 Pages
-
Bottom-Entry Pressure Gauges
2 Pages
-
Flanged Gate Valves
2 Pages
-
Brass Midi Check Valves
2 Pages
-
Wafer Style Butterfly
2 Pages
-
carbon steel ball valve
2 Pages