Overview: The Series 142 Process Boiler Water Feeders are designed for use in heating applications, particularly on pressing machines and small process boilers. They allow direct feed through the float chamber, maintaining the correct water level automatically.
Specifications:
  • Size: 1/2" (15mm) NPT female water feed connection and 1" (25mm) NPT female float chamber connection.
  • Maximum Working Pressure: 100psi (6.9 bar) for steam and 145psi (10.0 bar) for water.
  • Water pressure must be at least 10psi (69 kPa) higher than steam pressure.
Features:
  • Automatic water feed system.
  • Available with or without a strainer (Model 142S includes a strainer).
  • Easy cleaning due to simple construction.
Materials:
  • Body made of cast iron.
  • Strainer made of bronze.
Applications: Suitable for both residential and commercial applications.
Installation: The document provides a diagram indicating installation methods when boiler tappings are not available.
Dimensions and Capacity:
  • Overall dimensions include various NPT connections and specific measurements for installation.
  • Capacity varies with the difference between steam and water pressure, with a range of boiler horsepower from 8 to 19.
Additional Information: The document notes that specifications are approximate and subject to change without notice. For precise measurements, contact Watts Technical Service.
See more

Catalog excerpts

Series 142-1

ES-142 For Residential and Commercial Applications Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location ––––––––––––––––––––––––––––––––––––––––– Approval Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––––––– –––––––––––––––––––––––––––––––––––––––– Series 142 Process Boiler Water Feeder with Direct Feed Through Float Chamber Size: 1/2" (15mm) Series 142 Process Boiler Water Feeders are used in heating applications on pressing machines and other small process boilers when direct feed through the float chamber is permissible. This series has direct water feed connections – a 1/2" (15mm) NPT female water feed connection and a 1" (25mm) NPT female float chamber connection. Water is fed automatically as needed to maintain the correct water operating level in the boiler. The entire unit is simple in design and operation, easy to install, and inexpensive to operate. The simple construction of the feed valve permits quick and easy cleaning should it become fouled by dirt in the water supply. 142 Features • Direct water feed connections: 1/2" (15mm) NPT female water feed connection 1" (25mm) NPT female float chamber connection • Automatic water feed • Strainer (Model 142S) • Easy cleaning Models 142-without strainer 142S -with strainer Pressure-Temperature Maximum Working Pressure: 100psi (6.9 bar) Steam Maximum Working Pressure: 145psi (10.0 bar) Water The water pressure must be at least 10psi (69 kPa) higher than steam pressure Materials Body: Cast Iron Strainer: Bronze Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

 Open the catalog to page 1
Series 142-2

Dimensions Capacity DIFF. BETWEEN STEAM AND WATER PRESSURE BOILER HORSE POWER 10 20 30 40 50 8 13 16 18 19 8 7/8" (225mm) 1" N.P.T. 6" (152mm) Check Valve E 3 8 1/" (35mm) 21/2" (60mm) 3 8 1/" (60mm) 1" N.P.T. 47/8" (124mm) 1 2 / " N.P.T. Shutoff Dotted lines indicate method of installing when tappings in boiler shown in illustration are not available Watts Type 142 C D Water Safety & Flow Control Products ES-142 0811 Boiler A B Union F USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca © Watts Regulator...

 Open the catalog to page 2

All Watts Water Technologies catalogs and technical brochures

  1. Ball Valves

    28  Pages

  2. Solar Solutions

    20  Pages

  3. Series X65B

    2  Pages

  4. Steam Products

    24  Pages

  5. 008 PCQT

    2  Pages

  6. Series 17

    1  Page

  7. Series 152SS

    2  Pages

  8. Series 152A

    2  Pages

  9. Series 150A

    2  Pages

  10. Series 1450F

    1  Page

  11. Series 144

    2  Pages

  12. Model 127W

    2  Pages

  13. ES-127

    2  Pages

  14. Series 123LP

    1  Page

  15. Series 1156F

    2  Pages

  16. Series 100DT

    1  Page

  17. Series 05

    2  Pages

  18. Series 007

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.