Catalog excerpts
ES-1170_L1170 For Residential, Commercial and Institutional Applications Job Name ––––––––––––––––––––––––––––––––––––––––––––– Contractor – –––––––––––––––––––––––––––––––––––––––––––– Job Location – ––––––––––––––––––––––––––––––––––––––––– – Approval ––––––––––––––––––––––––––––––––––––––––––––––– Engineer – ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––– Approval – ––––––––––––––––––––––––––––––––––––––––––––– Representative –––––––––––––––––––––––––––––––––––––––––– Series 1170 and L1170 Hot Water Temperature Control Valves ASSE Standard 1017 Listed* Sizes: 1⁄2" – 1" (15 – 25mm) Series 1170, L1170 Hot Water Temperature Control Valves are specifically designed for mixing hot and cold water on hot water supply systems. They can be used for a variety of applications to reduce the temperature of the hot water from the system, and are ideal for radiant heat applications. This series features a “double throttling” design which combines the control of the hot and cold water to provide a sensitive response to changes in water temperature passing through the mixing chamber. The 1170-M2 can be set to any temperature between 90°F and 160°F (60°F and 120°F for model L1170-M2) with flow rates as low as 0.5 gpm and as high as 23 gpm (refer to capacity chart on the back). The superior flow characteristics of this valve provide accurate temperature control to the requirements of ASSE 1017* across the rated flow range. 1170-US-M2 1170-QC-M2 These valves also provide additional safety as they restrict mixed water out to a drip upon loss of cold water supply to the valve. As an added feature, the 1170-M2 and L1170-M2 incorporate integral check valves and filter washers in both the hot and cold water inlets to protect against cross flow. Available with threaded (-UT), solder (-US), Pex, (-QC) Quick-Connect or CPVC connections. Minimum flow requirements to maintain set temperature for Series 1170-M2 Valve Size gpm ⁄2" – 1" .5 1 Features • Bronze body construction • Solid wax hydraulic principle thermostat assures dependable mixing of hot and cold water • Thermostat controls both hot and cold water • Models available with solder, thread, Pex, Quick-Connect or cpvc end connections • Integral filter washers and check valves • Adjustment cap with locking feature • ASSE 1017 listed* Specifications A Hot Water Temperature Control Valve shall be installed on water heating equipment to provide tempered water to supply piping. Valve shall have a bronze body, include integral check valves and operate so the thermostat controls the cold and hot water ports. The valve shall be provided with solder (-US), threaded (-UT), pex, (-QC) Quick-Connect or cpvc connections. Valve shall be ASSE Standard 1017* Listed. Valve shall be a Watts Regulator Company 1170-M2 or L1170-M2. †WARNING Watts Hot Water Temperature Control Valve Series 1170 are designed to be installed at or near the boiler or water heater. They cannot be used by themselves for tempering water temperatures at fixtures where ASSE Standard 1016 or ASSE Standard 1070 listed devices are required. To comply with ASSE Standard 1016 or ASSE Standard 1070, listed devices such as Watts Series L111, USG or MMV should be used at fixtures to prevent possible injury. Watts Hot Water Temperature Control Valve Series 1170 are not designed to compensate for system pressure fluctuations. Such use may result in severe bodily injury (i. e. scalding or chilling) and/or death. When installing the Series 1170 valves in radiant heat applications, the components of the radiant heat system must be of materials with a construction capable of withstanding the high limit output temperatures of the heating boiler. If you are uncertain as to the product’s adaptability for your application, please consult an authorized representative before installing or using the product. *ASSE 1017 listing is for valves used in hot water source applications. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Open the catalog to page 1All Watts Water Technologies catalogs and technical brochures
-
Backflow Prevention
92 Pages
-
Hydronic Heating Specialties
60 Pages
-
WATTS.COM/CAD
1 Pages
-
Watts Flow Switch
2 Pages
-
Thermostatic Mixing Valves
12 Pages
-
Watts PRV Irrigation
1 Pages
-
Thermal Expansion Products
24 Pages
-
Water Pressure Reducing Valves
44 Pages
-
Flippen Float Valves
12 Pages
-
Ball Valves
28 Pages
-
Steam Pressure Regulators
8 Pages
-
Solar Solutions
20 Pages
-
OneFlow Model OFTWH
2 Pages
-
LavSafe Thermostatic Faucets
4 Pages
-
Series X65B
2 Pages
-
OneFlow® Anti-Scale Systems
2 Pages
-
Watts Boiler Header Module
4 Pages
-
Steam Products
24 Pages
-
008 PCQT
2 Pages
-
Series 17
1 Pages
-
Series 152SS
2 Pages
-
Series 152A
2 Pages
-
Series 150A
2 Pages
-
Series 1450F
1 Pages
-
Series 144
2 Pages
-
Series 142
2 Pages
-
Series 40, 140, 240 & 340
2 Pages
-
Model 127W
2 Pages
-
ES-127
2 Pages
-
Series 123LP
1 Pages
-
Series 1156F
2 Pages
-
Series 1L, 1XL, 10L
2 Pages
-
Series 100DT
1 Pages
-
Series 05
2 Pages
-
Series 007
4 Pages
-
Flow-Max Filters
4 Pages
-
Bottom-Entry Pressure Gauges
2 Pages
-
Flanged Gate Valves
2 Pages
-
Brass Midi Check Valves
2 Pages
-
Wafer Style Butterfly
2 Pages
-
carbon steel ball valve
2 Pages