1. Catalogs
  2. Watts Fluid Air
  3. Section: D Alternative Fuel

Section: D Alternative Fuel

Section: D Alternative Fuel
1 / 16 PagesView full catalog

Section: D Alternative Fuel

Product catalog summary
Overview: The document provides detailed information on the FFC Series Alternative Fuel Filters designed for use with alternative fuels such as Compressed Natural Gas (CNG), Liquid Natural Gas (LNG), and Liquid Propane Gas (LPG). These filters are essential for removing contaminants like oil, water, and particulates from fuel systems, ensuring the efficient operation of engines using these fuels.
Specifications: The FFC Series includes various models such as FFC-110-06, FFC-110L-10, FFC-112, FFC-113-NF-01, FFC-114, and FFC-116N. Each model has specific features including maximum pressure ratings, flow rates, port sizes, and dimensions. For example, the FFC-110-06 has a maximum pressure of 500 PSI and a flow rate of 25 SCFM, while the FFC-113-NF-01 can handle up to 3,600 PSI with a flow rate of 50 SCFM.
Filtration Technology: The filters use a patented coalescing process with micro-glass fibers to remove 99.97% of aerosols in the 0.3 to 0.6 micron range. This ensures that contaminants are effectively removed from the fuel, protecting engine components.
Installation and Maintenance: The document provides typical installation layouts and mounting information for each filter model. It is important to allow sufficient clearance for maintenance and draining of the filter elements.
Contact Information: For technical support, the document provides contact numbers and an email address for assistance.
See more

Catalog excerpts

Section: D Alternative Fuel-1

Alternative Fuel climate control process control sealing & shielding ENGINEERING YOUR SUCCESS.

 Open the catalog to page 1
Section: D Alternative Fuel-2

Alternative Fuel Questions? Contact Technical Support: e-mail: [email protected]

 Open the catalog to page 2
Section: D Alternative Fuel-3

Alternative Fuel These assemblies are designed and tested for today's new alternative fuels: Compressed Natural Gas (CNG), Liquid Natural Gas (LNG) and Liquid LPG have the same problems that plague diesel and gasoline, particulate contamination collects during handling, water condenses in tanks, and compressors leak oil into the fuel The precision components necessary alternative fuel system demand superior filtration. Racor anticipated the need for ultra-fine filtration at the pressures required by compressed industry's first, most complete and most efficient line of alternative fuel FFC series...

 Open the catalog to page 3
Section: D Alternative Fuel-4

Alternative Fuel Notes: 1. For accurate flow rates and pressures, consult your engine manual, engine manufactures agent, or the vehicle manufacturer. 2. Some specifications are the result of tests conducted at the optimum flow rate. 3. Allow 3.0 in. (7.6 cm) of clearance below assembly for draining and maintenance of element. Questions? Contact Technical Support: e-mail: [email protected]

 Open the catalog to page 4
Section: D Alternative Fuel-5

Alternative Fuel Notes: 1. For accurate flow rates and pressures, consult your engine manual, engine manufactures agent, or the vehicle manufacturer. 2. Some specifications are the result of tests conducted at the optimum flow rate. 3. Allow 3.0 in. (7.6 cm) of clearance below assembly for draining and maintenance of element. Questions? Contact Technical Support: e-mail: [email protected]

 Open the catalog to page 5
Section: D Alternative Fuel-6

Alternative Fuel Replacement Element Basic Unit Mounting Information Typical Installation Layout Fill Port Fuel Tanks High Pressure Questions? Contact Technical Support e-mail: [email protected]

 Open the catalog to page 6
Section: D Alternative Fuel-7

Alternative Fuel Replacement Element Basic Unit Mounting Information Typical Installation Layout Fill Port Fuel Tanks High Pressure Inlet Port ' Outlet Port Questions? Contact Technical Support: e-mail: [email protected]

 Open the catalog to page 7
Section: D Alternative Fuel-8

Alternative Fuel Customer Interface Drawing NOTES: UNLESS OTHERWISE SPECIFIED PORT SIZE: l/2"-l4 NPTF. RATED FLOW: 50 SCEM § 100 PSIG ALUMINUM G0GI MACHINED HEAD ALUMINUM 6061 DRAWN BOWL 7. ELEMENT GRADE AVAILABLE: 10 MICRON CHROMATED HEAD AND BOWL BLACK POWDER PAINTED EXTERIOR CUSTOMER INTERFACE DRAWING REVISE ONLY ON PEOE SYSTEM THIS PRINT SUPERSEDES ANÏ EARLIER DATE: DESTROY SAME S SUBJECT TO RETURN ON DEMAND Questions? Contact Technical Support: e-mail: [email protected]

 Open the catalog to page 8
Section: D Alternative Fuel-9

Alternative Fuel Replacement Element Mounting Information Typical Installation Layout Fill Port Fuel Tanks High Pressure Mounting Holes Questions? Contact Technical Support: e-mail: [email protected]

 Open the catalog to page 9
Section: D Alternative Fuel-10

Alternative Fuel Customer Interface Drawing - ISSUE DRAWING_ B ADDED SECTIONAL VIEW__ I.) i 2. ) ADDED NOTES 4 1 5 TO FILTER ~D~WAS ill GLASS REINFORCED NYLON ~ NOTES : UNLESS OTHERWISE SPECIFIED I. SERVICE WORKING PRESSURE : 3600 PSI DRAIN PLUG: 8 FT - LBS ± I FT-LB HOUSING TO HEAD: 40 FT-LBS ± I FT-LB 5. FLOW: INSIDE TO OUT ELEMENT FILTER ELEMENT: (SPECIFY GRADE 6 OR 10] I. DRT FLOW RATING: 30 SCFM S 100 P3IG 3. TÏP. ADDITIONAL PRESSURE REQUIRED TO DRAIN I COALESCER WHEN OIL WET: 2.0 PSID. REVISE ONLY ON Pro/E SYSTEM CUSTOMER INTERFACE DRAWING HIGH PRESSURE COALESCER/FILTER Questions? Contact...

 Open the catalog to page 10
Section: D Alternative Fuel-11

Alternative Fuel Replacement Element Basic Unit Mounting Information Typical Installation Layout Fill Port Fuel Tanks High Pressur Questions? Contact Technical Support: e-mail: [email protected]

 Open the catalog to page 11
Section: D Alternative Fuel-12

Alternative Fuel Replacement Element Basic Unit Mounting Information Typical Installation Layout Fill Port Fuel Tanks High Pressure Outlet Port Mounting Holes Inlet Port Questions? Contact Technical Support e-mail: [email protected]

 Open the catalog to page 12
Section: D Alternative Fuel-13

Alternative Fuel Customer Interface Drawing NOTES; UNLESS OTHERWISE SPECIFIED- DIMENSION IN PARENTHESIS ARE FOR REFERENCE ONLY. MATERIAL: 303 STAINLESS STEEL. SERVICE WORKING PRESSURE: 3,600 PS RECOMMENDED TORQUE DRAIN PLUG : 8FT-LBS ± IFT-LB BODY TO HEAD: 30FT-LBS ± IFT-LB FLOW: I NS I DE TO OUTS I DE ELEMENT. ELEMENT REMOVAL CLEARANCE: 5" MIN CUSTOMER INTERFACE DRAWING REV I SE ONLY ON ProE SYSTEM THIS PRINT SUPERSEDES ANY EARLIER DATE: DESTROY SAME Questions? Contact Technical Support: e-mail: [email protected]

 Open the catalog to page 13
Section: D Alternative Fuel-14

Alternative Fuel Replacement Element Basic Unit Mounting Information Typical Installation Layout Fill Port Fuel Tanks High Pressure Mounting Holes Inlet Port Questions? Contact Technical Support e-mail: [email protected]

 Open the catalog to page 14
Section: D Alternative Fuel-15

Alternative Fuel Part Number Index Questions? Contact Technical Support: e-mail: [email protected]

 Open the catalog to page 15
Section: D Alternative Fuel-16

Alternative Fuel _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________...

 Open the catalog to page 16
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.