1. Catalogs
  2. WATTCO
  3. STRIP HEATERS

STRIP HEATERS
1 /8Pages

STRIP HEATERS

STRIP HEATERS
1 /8Pages

Catalog excerpts

STRIP HEATERS-1

STRIP AND FINNED STRIP HEATERS component parts

 Open the catalog to page 1
STRIP HEATERS-2

WATTCO™ strip heaters are composed of a heating element, a protective sleeve or sheath, and mounting hardware. Used as radiant heaters, they have finned strips to maximize surface area and heat transfer to the air. They are clamped or bolted onto objects or solid surfaces in several heating applications. Our strip heaters are the best versatile choice to provide good surface contact heating over large areas. STRIP AND FINNED STRIP HEATERS component parts • Winterizing: o Hoppers o Conveyors o Ducts o Car heating systems o Thawing o Control Panels KEY FEATURES • Equipped with insulation to reduce...

 Open the catalog to page 2
STRIP HEATERS-3

STRIP AND FINNED STRIP HEATERS component parts CPO**T1 strip heaters are made of two offset bolt type terminals at one end. Refer to Table 1 for a list of heaters with an aluminized steel sheath. • Listed standard strip heaters ratings: 120V and 240V. • Heaters with 287V are also available. • You can also use the following strip heaters listed below with lower voltages. • You can also use higher voltages with some strip heaters. • For higher temperatures, use stainless steel heaters as referred in Table 2. • Use additional insulators when voltage to ground is over 300V. Refer to page 6.7 SHEATH...

 Open the catalog to page 3
STRIP HEATERS-4

STRIP AND FINNED STRIP HEATERS component parts CPS**T1 STRIP HEATERS TYPE CPS**T1 strip heaters are made of two bolt type terminals at one end. Refer to Table 2 below for a list of heaters with high temperature stainless steel sheath. • Listed standard strip heaters ratings: 120V and 240V. • Heaters with 287V are also available. • You can also use the following strip heaters listed below with lower voltages. • You can also use higher voltages with some strip heaters. • For higher temperatures, use stainless steel heaters as referred in Table 2. • Use additional insulators when voltage to ground...

 Open the catalog to page 4
STRIP HEATERS-5

STRIP AND FINNED STRIP HEATERS component parts Type CPO**T2 strip heaters are made of two bolt type terminals at opposite ends. Refer to Table 3 for a list of heaters with an aluminized steel sheath. • Listed standard strip heaters ratings: 120V and 240V. • Heaters with 287V are also available. • You can also use the following strip heaters listed below with lower voltages. • You can also use higher voltages with some strip heaters. • If higher temperatures are reached, use stainless steel heaters as referred in Table 4. • Use additional insulators when voltage to ground is over 300V. Refer to...

 Open the catalog to page 5
STRIP HEATERS-6

STRIP AND FINNED STRIP HEATERS component parts CPS**T2 STRIP HEATERS WITH STAINLESS STEEL SHEATH Refer to Table 4 below for a list of heaters with high temperature stainless steel sheath. • Listed standard strip heaters ratings: 120V and 240V. • Heaters with 287V are also available. • You can also use the following strip heaters listed below with lower voltages. • You can also use higher voltages with some strip heaters. • If higher temperatures are reached, use stainless steel heaters as referred in Table 4. • Use additional insulators when voltage to ground is over 300V. Refer to page 6.7 SHEATH...

 Open the catalog to page 6
STRIP HEATERS-7

STRIP AND FINNED STRIP HEATERS component parts Type CPF**T2 strip heaters are made of two offset bolt type terminals at one end. Refer to Table 5 for a list of heaters with aluminized steel sheath. • Listed standard strip heaters ratings: 120V and 240V. • Heaters with 287V are also available. • You can also use the following strip heaters listed below with lower voltages. • You can also use higher voltages with some strip heaters. • Use additional insulators when voltage to ground is over 300V. Refer to Page 6.7 • Fins dimensions: o 0.022” thick cadmium plated steel with a nominal four fins per...

 Open the catalog to page 7
STRIP HEATERS-8

STRIP AND FINNED STRIP HEATERS component parts EXTRA FEATURES SPECIAL WATTAGE, VOLTAGE, AND LENGTHS Call us at 1.800.4WATTCO if you need a custom designed heater for your application. LENGTHWISE BENDING Call us at 1.800.4WATTCO (1.800.492.8826) if you need lengthwise bending for your application. FINNED STRIP HEATERS WATTCO™ CPF strip heaters can be supplied with offset terminals and can also be made of fins upon request. ADDITIONAL INSULATORS Use additional insulators when voltage to ground is over 300V. EXTRA FEATURES / DESCRIPTION FIGURE 1 - CAT. NO. P1231 Use the following insulator if a...

 Open the catalog to page 8

Archived catalogs

  1. TUBULAR HEATERS

    13  Pages

  2. BAND HEATERS

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.