Catalog excerpts
ul Sifijrli: ^isaJL'jy =iars«nb.sih£l Csrursib
Open the catalog to page 1BENEFITS » Easy to install » Perfect for higher kilowatt output applications » Appropriate heater size provided for the application and fit » Designed and built for safety OVERVIEW WATTCO™ flange heaters are made using hairpin or bugle type tubular elements using incoloy® sheathed elements that are welded or silver-brazed into a pipe or steel flange. Perfectly designed to be mounted in tanks and pressurized vessels, WATTCO™ flange heaters are used for heating liquid mediums or other specific types of liquids, and for heating gases (water, oil, heat transfer fluid, and corrosive...
Open the catalog to page 22 1/2" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available Moisture resistant Terminal Box Explosion resistant Terminal Box HEATER DIMENSION IN INCHES FLANGE RATING TABLE 1 2 1/2” - 3” Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES WATT WITHOUT WITH NET COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase 61.7 FLC305X2016 FLC305X2016T 16 INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase 61.7 FLI305X2016 FLI305X2016T 16 STEEL...
Open the catalog to page 33" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available FLANGE RATING TABLE 2 3" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 5 813 32 1 or 3 Phase 23.7 FLO305X2432 FLO305X2432T 16 STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 2 813 32 1 or 3 Phase 9.5 FLO302X2432 FLO302X2432T 18...
Open the catalog to page 4- FLANGE HEATERS immersion heaters4" FLANGE HEATERSRefer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available FLANGE RATING 4" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES WATT WITHOUT WITH NET COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 279 11 1 or 3 Phase 61.7 FLC605X2811 FLC605X2811T 16 INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 279 11 1 or 3 Phase 61.7 FLI605X2811 FLI605X2811T 16 STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY...
Open the catalog to page 5Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available TABLE 4 5" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 10 406 16 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 10 406 16 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 5 381 15 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 2 381 15 1 or 3 Phase FLANGE RATING WITH NET WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue...
Open the catalog to page 6Refer to PAGE 2 for the GENERAL RECOMMENDATIONS HEATER DIMENSION IN INCHES NGE FLANGE ZE RATING 150 lb. IMMERSION LENGTH B VOLTAGES NET WT. LBS (approx.) COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 30 533 21 1 or 3 Phase 64.9 INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 30 533 21 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 15 559 22 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 10 787 31 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue number, voltage, phase, wattage, material to be heated, flowing...
Open the catalog to page 78" FLANGE HEATERS HEATER DIMENSION IN INCHES Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available 8" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES WITHOUT WITH NET COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 50 584 23 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 50 584 23 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 40 762 30 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 20 813 32 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY: Quantity,...
Open the catalog to page 810" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available is >< GO O *<7> CD <D — 5- ro c c TABLE 7 10" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 100 660 26 1 or 3 Phase 140 813 32 " INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 100 660 26 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 100 1118 44 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 70 1600 63 1 or 3 Phase WHEN ORDERING, PLEASE...
Open the catalog to page 912" FLANGE HEATERS HEATER DIMENSION IN INCHES Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available TABLE 8 12" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 150 71 1 28 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 150 71 1 28 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 150 1245 49 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 100 1727 68 1 or 3 Phase WHEN ORDERING, PLEASE...
Open the catalog to page 1014" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available HEATER DIMENSION IN INCHES TABLE 9 14" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 250 864 34 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 250 864 34 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 150 889 35 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 100 1219 48 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue...
Open the catalog to page 11All WATTCO catalogs and technical brochures
-
CARTRIDGE HEATERS
6 Pages
-
SILICONE HEATERS
4 Pages
-
Tubular_Heaters
13 Pages
-
Immersion_Heaters
4 Pages
-
Over_The_Side_Heaters
5 Pages
-
Screw_Plug_Heaters
12 Pages
-
BAND HEATERS
7 Pages
-
Immersion Heaters
4 Pages
-
INFRARED RADIANT HEATERS
11 Pages
-
CONTROL PANELS
13 Pages
-
DUCT HEATERS
6 Pages
-
OPEN COIL ELEMENTS
3 Pages
-
SILICONE RUBBER HEATERS
4 Pages
-
BAND HEATERS
7 Pages
-
CARTRIDGE HEATERS
8 Pages
-
FINNED STRIP HEATERS
8 Pages
-
STRIP HEATERS
8 Pages
-
FINNED TUBULAR HEATING
13 Pages
-
TUBULAR HEATERS
13 Pages
-
PIPE HEATER
3 Pages
-
OVER THE SIDE HEATERS
5 Pages
-
SCREW PLUG HEATERS
12 Pages
-
Inline Heaters
13 Pages
-
Circulation Heaters Catalogue
13 Pages