Overview
WATTCO™ flange heaters are designed for heating liquids and gases in tanks and pressurized vessels. They feature hairpin or bugle type tubular elements with Incoloy® sheathed elements, welded or silver-brazed into a pipe or steel flange. These heaters are suitable for various mediums, including water, oil, heat transfer fluids, and corrosive solutions.
Key Features
  • Standard sizes range from ½” to 42” with diameters of 0.260” to 0.625”.
  • Available in copper, steel, or stainless steel, with flanges in 150lb or 300lb forged steel.
  • Elements can be made from Incoloy®, Inconel®, stainless steel, copper, or titanium.
  • Explosion and moisture-resistant terminal enclosures are available.
  • Custom sizes, wattages, and materials can be requested.
Benefits
  • Easy installation and maintenance.
  • Suitable for high kilowatt output applications.
  • Designed with safety in mind.
Selection Factors
  • Consider flange size, pressures, heating element watt density, tank length, sheath material, temperature, aeration, and velocity of the corrodent.
General Recommendations
Flange heaters are available in various sizes and materials for different applications, such as clean water, steam boilers, and mildly corrosive solutions. The choice of sheath and flange material depends on specific application requirements.
Ordering Information
Specify quantity, catalogue number, voltage, phase, wattage, material to be heated, medium type, control types, container metal/alloy, and any extra features. Inform if heaters are for steam-pressured applications.
Technical Specifications
Includes detailed tables with specifications for different flange sizes, kilowatts, immersion lengths, voltages, watt densities, and catalogue numbers for heaters with and without thermostats.
Procedures and Recommendations
  • Specify ordering requirements, including steam applications.
Additional Features
  • Passivation for corrosion resistance available for Incoloy® and stainless steel.
  • Built-in options like thermostat wells and thermocouples can be installed.
  • Moisture and explosion-resistant terminal housings available.
Standards and Norms
  • Construction details for Class 150 and Class 300 flanges, complying with ANSI B16.5 standards.
Applications
Suitable for water boilers, open storage tanks with degreasing solvents, fuel oils, heat-transfer fluids, and caustic solutions.
Tables
Includes tables listing flange sizes, standard voltages, catalogue numbers, and weights for different heater configurations, with specific warnings for steam applications.
See more

Catalog excerpts

Flanged Heaters Catalogue-1

ul Sifijrli: ^isaJL'jy =iars«nb.sih£l Csrursib

 Open the catalog to page 1
Flanged Heaters Catalogue-2

BENEFITS » Easy to install » Perfect for higher kilowatt output applications » Appropriate heater size provided for the application and fit » Designed and built for safety OVERVIEW WATTCO™ flange heaters are made using hairpin or bugle type tubular elements using incoloy® sheathed elements that are welded or silver-brazed into a pipe or steel flange. Perfectly designed to be mounted in tanks and pressurized vessels, WATTCO™ flange heaters are used for heating liquid mediums or other specific types of liquids, and for heating gases (water, oil, heat transfer fluid, and corrosive solutions)....

 Open the catalog to page 2
Flanged Heaters Catalogue-3

2 1/2" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available Moisture resistant Terminal Box Explosion resistant Terminal Box HEATER DIMENSION IN INCHES FLANGE RATING TABLE 1 2 1/2” - 3” Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES WATT WITHOUT WITH NET COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase 61.7 FLC305X2016 FLC305X2016T 16 INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase 61.7 FLI305X2016 FLI305X2016T 16 STEEL SHEATH...

 Open the catalog to page 3
Flanged Heaters Catalogue-4

3" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available FLANGE RATING TABLE 2 3" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 5 813 32 1 or 3 Phase 23.7 FLO305X2432 FLO305X2432T 16 STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 2 813 32 1 or 3 Phase 9.5 FLO302X2432 FLO302X2432T 18 WHEN...

 Open the catalog to page 4
Flanged Heaters Catalogue-5

- FLANGE HEATERS immersion heaters4" FLANGE HEATERSRefer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available FLANGE RATING 4" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES WATT WITHOUT WITH NET COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 279 11 1 or 3 Phase 61.7 FLC605X2811 FLC605X2811T 16 INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 279 11 1 or 3 Phase 61.7 FLI605X2811 FLI605X2811T 16 STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 5 381 15 1 or 3 Phase 22.8 FLO905X2815 FLO905X2815T 16...

 Open the catalog to page 5
Flanged Heaters Catalogue-6

Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available TABLE 4 5" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 10 406 16 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 10 406 16 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 5 381 15 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 2 381 15 1 or 3 Phase FLANGE RATING WITH NET WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue number,...

 Open the catalog to page 6
Flanged Heaters Catalogue-7

Refer to PAGE 2 for the GENERAL RECOMMENDATIONS HEATER DIMENSION IN INCHES NGE FLANGE ZE RATING 150 lb. IMMERSION LENGTH B VOLTAGES NET WT. LBS (approx.) COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 30 533 21 1 or 3 Phase 64.9 INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 30 533 21 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 15 559 22 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 10 787 31 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue number, voltage, phase, wattage, material to be heated, flowing or...

 Open the catalog to page 7
Flanged Heaters Catalogue-8

8" FLANGE HEATERS HEATER DIMENSION IN INCHES Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available 8" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES WITHOUT WITH NET COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 50 584 23 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 50 584 23 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 40 762 30 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 20 813 32 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue...

 Open the catalog to page 8
Flanged Heaters Catalogue-9

10" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available is >< GO O *<7> CD <D — 5- ro c c TABLE 7 10" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 100 660 26 1 or 3 Phase 140 813 32 " INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 100 660 26 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 100 1118 44 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 70 1600 63 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY:...

 Open the catalog to page 9
Flanged Heaters Catalogue-10

12" FLANGE HEATERS HEATER DIMENSION IN INCHES Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available TABLE 8 12" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 150 71 1 28 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 150 71 1 28 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 150 1245 49 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 100 1727 68 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY:...

 Open the catalog to page 10
Flanged Heaters Catalogue-11

14" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available HEATER DIMENSION IN INCHES TABLE 9 14" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 250 864 34 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 250 864 34 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 150 889 35 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 100 1219 48 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue number,...