Flanged Heaters Catalogue - 1

ul Sifijrli: ^isaJL'jy =iars«nb.sih£l Csrursib

Open the catalog to page 1
Flanged Heaters Catalogue - 2

BENEFITS » Easy to install » Perfect for higher kilowatt output applications » Appropriate heater size provided for the application and fit » Designed and built for safety OVERVIEW WATTCO™ flange heaters are made using hairpin or bugle type tubular elements using incoloy® sheathed elements that are welded or silver-brazed into a pipe or steel flange. Perfectly designed to be mounted in tanks and pressurized vessels, WATTCO™ flange heaters are used for heating liquid mediums or other specific types of liquids, and for heating gases (water, oil, heat transfer fluid, and corrosive...

Open the catalog to page 2
Flanged Heaters Catalogue - 3

2 1/2" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available Moisture resistant Terminal Box Explosion resistant Terminal Box HEATER DIMENSION IN INCHES FLANGE RATING TABLE 1 2 1/2” - 3” Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES WATT WITHOUT WITH NET COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase 61.7 FLC305X2016 FLC305X2016T 16 INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase 61.7 FLI305X2016 FLI305X2016T 16 STEEL...

Open the catalog to page 3
Flanged Heaters Catalogue - 4

3" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available FLANGE RATING TABLE 2 3" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 406 16 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 5 813 32 1 or 3 Phase 23.7 FLO305X2432 FLO305X2432T 16 STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 2 813 32 1 or 3 Phase 9.5 FLO302X2432 FLO302X2432T 18...

Open the catalog to page 4
Flanged Heaters Catalogue - 5

- FLANGE HEATERS immersion heaters4" FLANGE HEATERSRefer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available FLANGE RATING 4" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES WATT WITHOUT WITH NET COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 279 11 1 or 3 Phase 61.7 FLC605X2811 FLC605X2811T 16 INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 5 279 11 1 or 3 Phase 61.7 FLI605X2811 FLI605X2811T 16 STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY...

Open the catalog to page 5
Flanged Heaters Catalogue - 6

Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available TABLE 4 5" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 10 406 16 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 10 406 16 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 5 381 15 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 2 381 15 1 or 3 Phase FLANGE RATING WITH NET WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue...

Open the catalog to page 6
Flanged Heaters Catalogue - 7

Refer to PAGE 2 for the GENERAL RECOMMENDATIONS HEATER DIMENSION IN INCHES NGE FLANGE ZE RATING 150 lb. IMMERSION LENGTH B VOLTAGES NET WT. LBS (approx.) COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 30 533 21 1 or 3 Phase 64.9 INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 30 533 21 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 15 559 22 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 10 787 31 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue number, voltage, phase, wattage, material to be heated, flowing...

Open the catalog to page 7
Flanged Heaters Catalogue - 8

8" FLANGE HEATERS HEATER DIMENSION IN INCHES Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available 8" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES WITHOUT WITH NET COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 50 584 23 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 50 584 23 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 40 762 30 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 20 813 32 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY: Quantity,...

Open the catalog to page 8
Flanged Heaters Catalogue - 9

10" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available is >< GO O *<7> CD <D — 5- ro c c TABLE 7 10" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 100 660 26 1 or 3 Phase 140 813 32 " INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 100 660 26 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 100 1118 44 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 70 1600 63 1 or 3 Phase WHEN ORDERING, PLEASE...

Open the catalog to page 9
Flanged Heaters Catalogue - 10

12" FLANGE HEATERS HEATER DIMENSION IN INCHES Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available TABLE 8 12" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 150 71 1 28 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 150 71 1 28 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 150 1245 49 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 100 1727 68 1 or 3 Phase WHEN ORDERING, PLEASE...

Open the catalog to page 10
Flanged Heaters Catalogue - 11

14" FLANGE HEATERS Refer to PAGE 2 for the GENERAL RECOMMENDATIONS Terminal Boxes Available HEATER DIMENSION IN INCHES TABLE 9 14" - 3" Cold Section - 150 lb. Steel Flange KILOWATTS IMMERSION VOLTAGES COPPER SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 250 864 34 1 or 3 Phase INCOLOY SHEATH - 65 WPSI (Approx.) - HIGH DENSITY 250 864 34 1 or 3 Phase STEEL SHEATH - 23 WPSI (Approx.) - MEDIUM DENSITY 150 889 35 1 or 3 Phase STEEL SHEATH - 10 WPSI (Approx.) - LOW DENSITY 100 1219 48 1 or 3 Phase WHEN ORDERING, PLEASE SPECIFY: Quantity, catalogue...

Open the catalog to page 11

All WATTCO catalogs and technical brochures

  1. BAND HEATERS

    7 Pages

  2. CONTROL PANELS

    13 Pages

  3. DUCT HEATERS

    6 Pages

  4. BAND HEATERS

    7 Pages

  5. PIPE HEATER

    3 Pages

  6. Inline Heaters

    13 Pages