Operator Interfaces
12Pages

{{requestButtons}}

Catalog excerpts

Operator Interfaces - 1

Operator Interfaces Note: The specifications in the table above are best available values in each category. Not all combinations of these values are available in a single model number.

Open the catalog to page 1
Operator Interfaces - 3

Silver Series EM The Silver Series EM is a rugged, touch-screen operator interface terminal (OIT). Available in three sizes (4.3, 7 and 10 inch diagonal display sizes), the OIT’s feature serial and Ethernet communications with multiple controllers, email messaging, universal serial bus (USB host), data logging, flexible password security and multiple languages. The small bezel size and two-inch depth make mounting in tight spots easy. The Silver Series EM programming software, EZwarePlus, is easy to use and features a large variety of built-in screen objects that makes it powerful. When...

Open the catalog to page 3
Operator Interfaces - 4

Operator Interfaces Silver Series EM Features and Benefits (Continued) Two-year warranty • Provides product support and reliability Screen object password security with programmable hierarchy and multiple users • Prevents errors and tampering by allowing only authorized users to access restricted items on the screen • Allows flexible hierarchies by letting the developer assign each screen object to any of 12 groups and grant each user access to any combination of groups • Provides password protection for upload, download and access to local setup • Supports up to 127 users Screen object...

Open the catalog to page 4
Operator Interfaces - 5

Operator Interfaces Silver Series EM Dimension and Connection Diagrams Models TS00-0043-EM00/TS00-0043-EM0B Fuse Switches and reset button Power connector Serial ports USB host port Ethernet port Rear View Front View Bottom View Fuse Switches and reset button Power connector Serial ports Ethernet port USB host port Front View Rear View Bottom View

Open the catalog to page 5
Operator Interfaces - 6

EZwarePlus Software System Requirements Compatible Operating Systems: • Windows® 10, 8.1 and 7

Open the catalog to page 6
Operator Interfaces - 7

EZwarePlus Software Suite The EZwarePlus software suite includes EasyConverter, EZwarePlus screen editor. Utility Manager and Recipe Editor programs. Utility Manager uploads and downloads projects to and from the Silver Series EM OIT, opens compiled projects in simulation and launches the other EZwarePlus programs. The Recipe Editor configures memory files for use with Silver Series EM OITs and allows offline creation of recipes. EasyConverter converts log files saved by the Silver Series EM OIT to file formats used by popular Windows® software such as Microsoft® Excel®. Draw Objects...

Open the catalog to page 7
Operator Interfaces - 8

Operator Interfaces Silver Series EM Connectivity Silver Series EM connects via… …to one Watlow EZ-ZONE® product equipped with Modbus® RTU or one third-party product via a supported protocol. …to one or more Watlow EZ-ZONE products equipped with Modbus® RTU or one or more third-party products via a supported protocol. …to an email server keeping technicians and operators informed. …to Watlow EZ-ZONE products equipped with Modbus® TCP and third-party products via supported protocols. …to VNC Client software for remote monitoring with a personal computer. Ordering Information Part Number 4.3...

Open the catalog to page 8
Operator Interfaces - 9

EZ-ZONE® RUI and Gateway The EZ-ZONE® Remote User Interface (RUI and communications gateway) can be utilized as a communication gateway device to save cost, space and wiring when digital communications is being used with two or more EZ-ZONE controllers. The EZ-ZONE RUI can also serve as a display for showing all parameter values for up to 16 EZ-ZONE controllers, again saving cost, space and wiring expenses. Indicator Features and Benefits—Remote User Interface (RUI) Single user interface device or location to access multiple controllers • Easy accessibility to all controllers and all...

Open the catalog to page 9
Operator Interfaces - 10

Operator Interfaces EZ-ZONE RUI and Gateway Specifications Line Voltage/Power • Universal high voltage 100 to 240VAC, +10%/-15%; (85-264VAC), 50/60Hz, ±5% • Low voltage 20 to 28VAC or 25 to 40VDC, 50/60Hz, ±5% for RUI only in short case version • Low voltage 20 to 28VAC or 12 to 40VDC, 50/60Hz, ±5% for RUI and Gateway in long case version • Data retention upon failure via nonvolatile memory Environment • 0 to 149°F (-18 to 70°C) operating temperature • -40 to 185°F (-40 to 85°C) storage temperature • 0 to 90% RH, non-condensing Wiring Termination—Touch-Safe Terminals • Terminals touch safe,...

Open the catalog to page 10
Operator Interfaces - 11

Remote User Interface (RUI)— Accessory—DIN-Rail Mounting BracketDimensional Drawings Part Number: °822-0586-P°02 Front View Front View Short Case Version 0.66 in. (16.79 mm) Rear View

Open the catalog to page 11
Operator Interfaces - 12

Ordering Information EZK ® ® Future Options & Remote User Interface (RUI)

Open the catalog to page 12

All Watlow Electric Manufacturing Company catalogs and technical brochures

  1. OPTIMAX

    3 Pages

  2. HELIMAX

    2 Pages

  3. POWERSAFE

    2 Pages

  4. 2704

    8 Pages

  5. 2704MP

    4 Pages

  6. 2704CP

    4 Pages

  7. EPC3000

    15 Pages

  8. SEMICONDUCTOR

    18 Pages

  9. Indicators

    6 Pages

  10. Data Loggers

    16 Pages

  11. Air Heaters

    34 Pages

  12. ASPYRE

    8 Pages

Archived catalogs