WATLOW Basic Temperature and Limit Controllers Features and Benefits Fixed or adjustable set points • Provide tamper-proof operation • Offer control flexibility Four character LED display • Improves set point selection accuracy Multiple mounting options • Minimize installation time Heat or cool operation • Provides application flexibility High or low limit with auto or manual reset • Provides application flexibility Fahrenheit or Celsius operation with indication • Offers application flexibility Sensor break protection • Provides positive system shutdown Agency approvals • Meet certification requirements/compliance Microprocessor-based technology • Ensures accurate, repeatable control Typical Applications • Food preparation • Industrial machinery • Packaging • Plastics processing Basic Temperature and Limit Controllers Provide Economical Solution for a Wide Range of Applications The basic and limit microprocessor-based controllers from Watlow® provide an economical solution for applications requiring simple on-off control. These controllers and limits are available in a broad range of packaging options, allowing users to select the best version for their individual application. The controllers and limits are available with or without an operator interface and can be ordered in a 1/8 DIN square panel mount, DIN-rail mount or open-board design configurations. The basic and limit design provides significant improvements in the performance, repeatability and accuracy offered by analog basic temperature and limit controllers. The variable options for the SERIES CV (controller) and SERIES LV (limit) include an operator interface for viewing and selecting the set point. A red, four-character, seven segment LED displays the set point to show the process option. The set point selection is made with a continuous turn rotary encoder, or with discrete up/down cursor keys. Operating range temperature values are customer definable in the product configuration part number. The fixed options for the SERIES CF (controller) and SERIES LF (limit) offer fixed set points and are supplied without an operator interface. Operating set point temperature values are customer definable in the product configuration part number. The SERIES TM temperature indicator is available as an additional order option. These basic and limit controllers are UL® recognized and include CE approvals. The limit controllers are FM approved with special UL® approval for the open-board potted versions. CV and LV panel mount controllers ordered with discrete up/down cursor keys include NEMA 4X/IP65 seal protection. Watlow's basic temperature and limit controllers include industry leading service and support and are backed by a three-year warranty.
Open the catalog to page 1at standard conditions and actual calibration ambient per degree change in ambient or -200 to 800°C or -210 to 1038°C or -270 to 1370°C or -270 to 400°C or -200 to 800°C Specifications On-Off Controller • Microprocessor based, on-off control mode • Nominal switching hysteresis, typically 3°F (1.7°C) • Input filter time: 1 second Limit Controller • Microprocessor based, limit controller • Nominal switching hysteresis, typically 3°F (1.7°C) • High or low limit, factory selectable • Latching output requires manual reset upon over or under temperature condition • Manual or automatic reset on...
Open the catalog to page 2Ordering Information AAAAAAAAA ® i Fixed Set Point Temperature Value Note: An A (-) used in the left most digit of the fixed set point indicates a negative temperature value.
Open the catalog to page 3Ordering Information Part Number Limit control with 8A relay output. Rotary set point adjustment, 4 character, 7 segment display, reset switch ®®@® Low Limit Set Point Operating Range Value Note: An A (-) used in the left most digit of the fixed set point indicates a negative temperature value. i High Set Operating Range Value Note: An A (-) used in the left most digit of the fixed set point indicates a negative temperature value.
Open the catalog to page 4i Low Set Point Operating Range Value Note: An A (-) is used in the left most digit of the set point operating ranges to indicate a negative temperature value. i High Set Operating Range Value Powered_by_Possibility To be automatically connected to the nearest North American Technical Sales Office: 1-800-WATLOW2 • www.watlow.com @@@@ Note: An A (-) is used in the left most digit of the set point operating ranges to indicate a negative temperature value. Watlow® is a registered trademark of Watlow Electric Manufacturing Company. UL® is a registered trademark of the Underwriter's...
Open the catalog to page 5All Watlow Electric Manufacturing Company catalogs and technical brochures
-
FIREROD® Cartridge Heaters
12 Pages
-
OPTIMAX
3 Pages
-
HELIMAX
2 Pages
-
POWERSAFE
2 Pages
-
Piccolo™ P304i
4 Pages
-
2704
8 Pages
-
2704MP
4 Pages
-
2704CP
4 Pages
-
6100A & 6180A
8 Pages
-
6000 Series graphic recorder
4 Pages
-
EPC3000
15 Pages
-
Eurotherm® EPower™
22 Pages
-
Flexible Heaters
12 Pages
-
w OPTIMAX® Heat Exchanger
2 Pages
-
Nozzle Heaters
4 Pages
-
Thermocouple Designs
2 Pages
-
SEMICONDUCTOR
18 Pages
-
Operator Interfaces
12 Pages
-
Indicators
6 Pages
-
Power Switching Devices
40 Pages
-
Data Loggers
16 Pages
-
Control Panels
6 Pages
-
Immersion Heaters
154 Pages
-
Tubular Heaters
52 Pages
-
Specialty Heaters
22 Pages
-
Radiant Heaters
10 Pages
-
High-Temperature Heaters
34 Pages
-
Nozzle Heaters
4 Pages
-
Fluid Delivery Heaters
8 Pages
-
Circulation Heaters
70 Pages
-
Flexible Heaters
36 Pages
-
Thermostats and Accessories
12 Pages
-
Air Heaters
34 Pages
-
DATA LOGGER with
8 Pages
-
PROCESS CONTROLLER
8 Pages
-
ASPYRE
8 Pages
-
FIREROD ® Cartridge Heaters
418 Pages
-
Heaters from Watlow
576 Pages
-
Energy Process
9 Pages
-
Sensor and Controller
418 Pages
-
serv-rite wire
8 Pages
-
SEMICONDUCTOR PROCESSING
34 Pages
-
SCR power controllers
6 Pages
-
multicell heaters
8 Pages
-
flexible heater
12 Pages
-
fiberbar flat tubular heater
8 Pages
-
thermal solutions
8 Pages
-
engine heater and systems
4 Pages
-
dinamite power controllers
20 Pages
-
Heat Solutions Resource
24 Pages
Archived catalogs
-
Application Guide
411 Pages
-
Application Guide catalog
216 Pages
-
Plastics catalog
411 Pages