SPECIFICATION SHEET WAT LOW Watlow's New WATCONNECT® Control Panels are Quickly Configured for Standard Two-Week Delivery Watlow® is now offering WATCONNECT® standard control panels that are quickly configured to your specific application requirements and delivered within two weeks. WATCONNECT panels integrate Watlow's high-quality heater, sensor, temperature controller and power controller products for a complete thermal solution. Normally, competitive custom panels require significantly longer lead times. The broad range of standard features allow customers to quickly configure panels that usually would be considered custom for delivery within two weeks. Watlow's customers will be impressed with the speed and ease of specifying, selecting, pricing, ordering and delivery. WATCONNECT panels are flexible and scalable; there are thousands of configurable, pre-engineered panel solutions available. Features and Benefits Full documentation provided for all WATCONNECT control panels at the time of quotation • Eliminates lengthy approval process and phone calls Watlow's F4T process controllers provide data logging and Ethernet • Provides real time and historical data management of process parameters Range of standard input / output (I/O) options • Provide the user with a higher level of monitoring and control, assuring an efficient and safe operation (See Communcations Interface Chart on page 4.) WATCONNECT enclosure easily mounts to wall or frame • Decreases installation time Bottom, right and top power entries • Provides multiple options for accessing and making connections to the inside of the panel IP-20 finger-safe construction • Decreases chance of electrical shock for service and maintenance personnel Fast acting fuses • Protects sensitive solid state components from damaging currents Available illuminated E-Stop • Allows quick emergency shut down Variety of cooling options • Suited for a wide range of environmental conditions Carbon steel and stainless steel enclosure materials available • Offers materials that are most economical for the user's application Supports a wide variety of sensor inputs including ASTM thermocouple types J, K and T, 3 wire 100 ohm RTD and 4 to 20mA process input • Provides the customer a variety of process signals to ensure compatibility with field equipment For more information on WATCONNECT go to www.watlow.com/watconnect Powered _by possibility^_ To be automatically connected to the nearest North American Technical Sales Office: 1-800-WATLOW2 • www.watlow.com International Technical Sales Offices: ©2020 Watlow Electric Manufacturing Company all rights reserved.
Open the catalog to page 1WATCONNECT Standard Control Panels Include: • UL®/cUL® listed control panels for installation in indoor/outdoor (shaded) and non-hazardous/hazardous locations • Wall or frame mount enclosures with hinged door, sized to accommodate one to four branch circuits and top, side or bottom power entry • Limited access and increased safety through the use of tool operated, A turn, mechanical latches that secure the hinged door to the enclosure • Molded case circuit breaker disconnect with through-door interlocked handle and lock out/tag out functionality (provides enhanced safety) • Fused branch circuit...
Open the catalog to page 2Configuration Options Control Panel Size SERIES Hazardous Class 1, Div. 2, Groups B/C/D or Class 1, Zone 2, Groups IIA/ IIB/IIC Hazardous Location 240V, 480V or 600V 3-phase, 50/60Hz 4 wire (3 power, 1 ground) (external 120V single phase necessary for purge operation) WATCONNECT®, DIN-A-MITE® and EZ-ZONE® are registered trademarks of Watlow Electric Manufacturing Company. UL® and cUL® are registered trademarks of Underwriter's Laboratories, Inc. Up to 8 (up to 2 process + up to 3 limits for each control loop/ zone Up to 8 (up to 2 process + up to 3 limits for each control loop/ zone See process...
Open the catalog to page 3PRELIMINARY RELEASE Dimensional Drawings C2 SERIES, Small, Non-Hazardous Location 2.17 in. (55 mm) C3 SERIES, Small, Hazardous Location Right Side View Left Side View Right Side View PRELIMINARY RELEASE Left Side View A UNLESS OTHERWISE SPECIFIED: DIMENSIONS AND TOLERANCING ARE IN INCHES AND PER ANSI Y14.5M THIRD ANGLE TOLERANCES: PROJECTION C2 CONTROL REVISIONS PANEL ASSY 4 C2 CONTROL PANEL DESCRIPTION NOTICE TO PERSONS RECEIVING THIS DRAWING WATLOW CLAIMS PROPRIETARY RIGHTS TO THE MATERIAL HEREIN DISCLOSED. IT IS SUPPLIED IN CONFIDENCE, WITHOUT PREJUDICE TO ANY PATENT RIGHTS OF WATLOW, AND...
Open the catalog to page 5C4 SERIES, Medium, Non-Hazardous Location D PRELIMINARY RELEASE PRELIMINARY RELEASE C5 SERIES, Medium, Hazardous Location 3.45 in. (88 mm) 23.62 in. (600 mm) Left Side View Right Side View NOTES:A 1. SEE INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR FIELD WIRING INFORMATION. Right Side View Left Side View 29 1.14 NOTES: 1. SEE INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR FIELD WIRING INFORMATION. A UNLESS OTHERWISE SPECIFIED: DIMENSIONS AND TOLERANCING ARE IN INCHES AND PER ANSI Y14.5M THIRD ANGLE TOLERANCES: PROJECTION PRELIMINARY RELEASE PRELIMINARY RELEASE NOTES: A 1. SEE INSTALLATION,...
Open the catalog to page 612 Pages
12 Pages
2 Pages
12 Pages
3 Pages
2 Pages
8 Pages
4 Pages
4 Pages
8 Pages
4 Pages
22 Pages
2 Pages
18 Pages
12 Pages
6 Pages
40 Pages
16 Pages
6 Pages
154 Pages
52 Pages
22 Pages
10 Pages
34 Pages
4 Pages
8 Pages
70 Pages
36 Pages
12 Pages
34 Pages
8 Pages
8 Pages
8 Pages
418 Pages
576 Pages
9 Pages
418 Pages
8 Pages
34 Pages
6 Pages
8 Pages
12 Pages
8 Pages
8 Pages
4 Pages
20 Pages
24 Pages
2 Pages
4 Pages
411 Pages
216 Pages
411 Pages