Adaptable power control expertise EPack-2PH Compact SCR Power Controllers Benefits OEMs and system integrators need to be able to react quickly to customer needs while maximizing resources. End users continually need to improve operational efficiency and productivity. Eurotherm EPack™2PH Compact SCR Power Controllers have been designed to deliver real savings, helping to reduce energy costs. Quick and easy to install, integrate and commission. Compact, with powerful and versatile features that help minimize costs whilst improving productivity and quality. • • • • • • • Improved energy consumption to help reduce energy bills Help maximize yield with accurate and repeatable control Customizable options provide better value for money Easy to specify with reduced number of hardware variants Fast integration and commissioning Monitor efficiently with integrated measurements Simplified design reduces stock and spares holding Key features • Native communication: Modbus® TCP and EtherNet/IP or PROFINET comms for easy connection to PLC • True power control • Large voltage capability from 100V to 500V adjustable in the same variant • Measurements: current, voltage, power, impedance, energy usage and more
Open the catalog to page 1Specifications General Safety specification Vibration tests Shock tests Approvals European community EN60947-4-3:2014: Low-voltage switchgear and controlgear - Part 4-3:Contactors and motor-starters AC semiconductor controllers and contactors for non-motor loads (identical to IEC60947-4-3:2014)Declaration of Conformity available on request. UL60947-4-1 CAN/CSA C22.2 NO.60947-4-1-14 Low-Voltage Switchgear and Controlgear - Part 4-1: Contactors and Motor-Starters - Electromechanical Contactors and Motor-Starters - U.L. File N° E86160 Regulatory Compliance Mark (RCM) to Australian Communication...
Open the catalog to page 2Specifications Mechanical details Unit Fuses Current rating Fuse holder size ≤25A with MS 32A with or without MS 40A with or without MS 50A with or without MS 63A with or without MS 80A with or without MS 100A with or without MS Power Nominal current Nominal voltage Accuracy Frequency Short circuit protection Rated conditionnal short-circuit current Utilization categories 4 to 125 amps From 100V to 500V +10%/–15% ±2% of full scale from 100V to 500V +10%/–15% 47Hz to 63Hz By external supplemental high speed fuses 100kA (coordination type 2) AC51 Resistive or slightly inductive load (cos phi>0.8)...
Open the catalog to page 3Specifications Communications Connection Protocols Speed rate Dual port Ethernet - RJ45 integrated switch Modbus TCP, EtherNet/IP, PROFINET 10/100 Mbps full or half duplex Display Technology Size Messages TFT 1.4” diagonal (35.56mm) Configuration, Monitoring and Diagnostics Additional functions Standard Counter, Logic & Math blocks, Linearization 16 points, Timer, Totalizer Energy counter, OEM security, Graphical wiring EPack - 2PH Compact SCR Power Controller Data Sheet
Open the catalog to page 4Mechanical details Connector details (pinout) I/O details Input connectors Digital inputs I/O connector Relay output Contact inputs Load power (output) 800Ω to ∞ = Open 0Ω to 450Ω = Closed 451Ω to 799Ω= Undefined 11V
Open the catalog to page 5Mechanical details Connector details (pinout) Input connectors Digital inputs Contact inputs 800Ω to ∞ = Open 0Ω to 450Ω = Closed 451Ω to 799Ω= Undefined Power mains line 1/L1 Auxiliary power supply Door catch (2 places)
Open the catalog to page 6Specifications EPack-2PH controller order codes The EPack power controller is ordered using a short code for hardware and chargeable software options and an optional extended code section configuration of commissioning options. If the extended code is not used, the software configuration is completed using a quick start procedure or using Eurotherm iTools software. EPack controllers may be upgraded with additional chargeable options at any time using a software key order code. 1 7 Compact SCR Power Controller Comms option Modbus TCP (standard) EtherNet/IP PROFINET Auxillary power supply 500V...
Open the catalog to page 7Specifications Software upgrade options 1 Serial number instrument Serial number No change Upgrade 16A to 25A Upgrade 16A to 32A Upgrade 25A to 32A Upgrade 40A to 50A Upgrade 40A to 63A Upgrade 50A to 63A Upgrade 80A to 100A Comms option No change EtherNet/IP PROFINET Graphical wiring No change Graphical wiring editor Control option No change Energy measurement Current ratings Energy option No change Upgrade V2 to I2 Upgrade V2 to PWR Upgrade I2 to PWR Transfer option No change I2 transfer Eurotherm Faraday Close, Worthing, West Sussex, BN13 3PL United Kingdom Phone: + 44 (0)1903 268500 Document...
Open the catalog to page 812 Pages
12 Pages
2 Pages
12 Pages
3 Pages
2 Pages
8 Pages
4 Pages
4 Pages
8 Pages
4 Pages
22 Pages
2 Pages
18 Pages
12 Pages
6 Pages
40 Pages
16 Pages
6 Pages
154 Pages
52 Pages
22 Pages
10 Pages
34 Pages
4 Pages
8 Pages
70 Pages
36 Pages
12 Pages
34 Pages
8 Pages
8 Pages
8 Pages
418 Pages
576 Pages
9 Pages
418 Pages
8 Pages
34 Pages
6 Pages
8 Pages
12 Pages
8 Pages
8 Pages
4 Pages
20 Pages
24 Pages
2 Pages
4 Pages
411 Pages
216 Pages
411 Pages