Data Loggers
Open the catalog to page 1D4T 1/4 DIN Data Logger The D4T with INTUITION® data logger offers a wide range of field removable I/O modules for maximum design flexibility. Configurations can be custom tailored to meet the scaling needs of a tremendous range of equipment and applications while providing exactly the hardware types required for compatibility. The D4T data logger also features a 4.3 inch, color, graphical touch panel. Combining power, flexibility and functionality, this new data logger offers unmatched versatility, and its best-in-class ease of use could very well make user manuals a thing of the past. Features...
Open the catalog to page 3D4T 1/4 DIN Data Logger Features and Benefits (con’t) Modular design • Adapts quickly to evolving requirements • Offers numerous types of field pluggable modules for maximum flexibility and easiest compatibility • Features scalable and modular firmware functions • Delivers scalable input/output quantities from 1 to 24 Agency certifications include UL®, FM, CE, RoHS, W.E.E.E., NEMA 4X/IP65 • Ensures high quality and reliability • Verifies performance in installations worldwide Off-the-shelf solution • Provides cost-effective “make versus buy” • Offers preconfigured touch-panel screens • Assures...
Open the catalog to page 4D4T 1/4 DIN Data Logger Agency Approvals • UL®/EN 61010 Listed, File E185611 QUYX • UL® 508 Reviewed • CSA CC.C#14, File 158031 • AMS 2750 E compliant: Analog input process values. Tip: Maximize field calibration accuracy and uniformity by using advanced F4T features such as Calibration Offset and Linearization Function Blocks. Refer to user manual for details. • RoHS by design, China RoHS Level 2, W.E.E.E. • CE • Windows® Hardware Certification Inputs and Outputs • Input sampling: 10Hz • Output update: 10Hz Communications • Ethernet Modbus® TCP • EIA-232/485 Modbus® RTU • Isolated communications...
Open the catalog to page 5Data Loggers D4T 1/4 DIN Data Logger Panel Mount Dimensions Slot 1 Slot 2 Slot 3 Accent Accent Bar Bar Accent Bar Slot 4 Slot 5 Slot 6 Mounting Panel Flush Mount Dimensions 4.62 in. (117.4 mm) Mounting Panel
Open the catalog to page 6D4T 1/4 DIN Data Logger Ordering InformationBase includes: 4.3 inch color graphical touch screen, standard bus communications, Ethernet Modbus® TCP and SCPI protocol. Part Number T = Touch screen Application Type ® ® Number of Logging Channels & Input Hardware Types Base Type
Open the catalog to page 7F4T With INTUITION® The F4T with INTUITION® temperature process controller offers a wide range of field removable I/O modules for maximum design flexibility. Configurations can be custom tailored to meet the scaling needs of a tremendous range of equipment and applications while providing exactly the hardware types required for compatibility. The F4T controller also features a 4.3 inch, color, graphical touch panel. Combining power, flexibility and functionality, this new controller offers unmatched versatility, and its best-in-class ease of use could very well make user manuals a thing of the...
Open the catalog to page 8EZ-ZONE® RM System with Access Module The EZ-ZONE® RM controller simplifies thermal system management. The EZ-ZONE RM controller family is comprised of six module types: an integrated on-off or PID control, monitoring and over/under temperature limit module, a high-density on-off or PID control module, a high-density limit only module, an input/output (I/O) expansion module, a high-density monitor/scanner module and a data logging and field communications access module. A system is configured by connecting any combination of module types to address specific application needs. The EZ-ZONE RM is...
Open the catalog to page 9RMA PLUS Remote Access Module Watlow’s new RMA PLUS remote access module supports Watlow’s powerful EZ-ZONE® RM temperature controller family by communicating with and providing access to all EZ-ZONE RM modules in a system. EZ-ZONE RMA users have had to spend more time than desired to connect their entire system. Now the RMA PLUS offers standard state-of-the-art connectivity from the device to the entire system. Real-time communication is possible via a built-in Ethernet switch or USB. Users can also connect to third-party and legacy devices because the RMA PLUS acts as a gateway between Modbus®...
Open the catalog to page 10SpecView HMI Software SpecView software is an easy-to-use Human Machine Interface (HMI) to Watlow controllers, including the F4T with INTUITION process controller and EZ-ZONE controllers as well as third-party products. Watlow’s single point of support for hardware, software and application needs ensures knowledgeable and expedient responses to questions or concerns. This competitively priced package includes field-proven features, many suggested by loyal users. Built-in support and auto-detect for Watlow controllers make setup quick and simple. SpecView is ideal for industrial applications with...
Open the catalog to page 11Data Loggers SpecView HMI Software Supported Controllers and Protocols Controller’s Communication Protocol Controller F4T with INTUITION EZ-ZONE RM, PM and ST POWER SERIES support for basic operation parameters is included. Automatic detection of EZ-ZONE instruments is not available via Modbus® so configurations must be set up manually. EZ-ZONE ST controllers versions 1 to 3 are supported via Modbus® with a RUI Gateway only. Application Examples Track and report batch-specific processing data. Graph and log process data. Replay data that may have been missed while a user was away. For playback...
Open the catalog to page 12Data Loggers SpecView HMI Software Ordering Information - Standard Part Number ActiveX Container Remote Users Update Plan ⑪ Third Party Drivers 0 = None 1 = Allen-Bradley® DF1 Note: Special drivers for other third-party products (Honeywell, Eurotherm, Mitsubishi, Yokogawa and Marathon) are available directly from SpecView. DDE and OPC None DDE OPC client Both Special Watlow Drivers None SERIES F4 programmer Historical Replay and Strategy Controller None Historical replay Strategy controller Both ⑪ Third Party Drivers Remote Users 00 = None XX = Number of simultaneous remote users (01 to 99) ⑩...
Open the catalog to page 1312 Pages
12 Pages
2 Pages
12 Pages
3 Pages
2 Pages
8 Pages
4 Pages
4 Pages
8 Pages
4 Pages
22 Pages
2 Pages
18 Pages
12 Pages
6 Pages
40 Pages
6 Pages
154 Pages
52 Pages
22 Pages
10 Pages
34 Pages
4 Pages
8 Pages
70 Pages
36 Pages
12 Pages
34 Pages
8 Pages
8 Pages
8 Pages
418 Pages
576 Pages
9 Pages
418 Pages
8 Pages
34 Pages
6 Pages
8 Pages
12 Pages
8 Pages
8 Pages
4 Pages
20 Pages
24 Pages
2 Pages
4 Pages
411 Pages
216 Pages
411 Pages