EUM-W Series Enclosed UniModule
8Pages

{{requestButtons}}

Catalog excerpts

EUM-W Series Enclosed UniModule - 1

EUM-W Series Enclosed UniModule Contamination-Proof Design Clean, quiet, operation. Nothing can get in, nothing can get out. Enclosed design eliminates damage to the working components. Prevents friction wear particles from escaping. Optional CBC-150 control can be mounted in conduit box Rugged, precision cast housing Single point electrical connection Encapsulated coils – 3 coil voltages Patented Autogaps™ automatically adjust for wear Easy set screw access NEMA C-face compatible design Totally enclosed One piece, C-face package completely assembled and factory aligned. Mates easily with standard motors and reducers. Foot mounted package also available. Easy-to-install and no maintenance required. • Factory burnished for out-of-box torque Bolt-it-down, wire-it-up. UniModule is ready to go. Automatic adjustment for wear. Complete control capability. • Optional integral control Available with built-in power supply or used with separate controls for soft starts and stops . . . or for fast acting, accurate cycling. • Superior heat transfer • Dual endbell for easy repair • Single point electrical connection • Optional conduit box EUM-W Washdown Unit EUM-W (white) units are ideal for applications that require frequent washing with high pressure spray systems. Improved Hub Design/Autogap System • Improved for longer spline life • Autogap functions over broad current range • New hub material Warner Electr

Open the catalog to page 1
EUM-W Series Enclosed UniModule - 2

EUM-W Series Enclosed UniModule EUM-W Series Clutch/Brakes and Clutch Combinations EUM-W Series Clutch/Brakes Washdown Unit The washdown version of the EUM uses stainless steel shafting, USDA approved coating, corrosion resistant fasteners and special sealing accessories for use in washdown applications. EUM-W (white) units are ideal for applications that require frequent washing with high pressure spray systems. Their smooth exterior does not allow food particles, or other contaminants, to get trapped and become host to bacteriological growth. • USDA approved coating • Stainless steel...

Open the catalog to page 2
EUM-W Series Enclosed UniModule - 3

EUM-W Series Enclosed UniModule Selection EUM-W - Selection Procedure Warner Electric EUM-W clutch/brake modules normally mount in either of two methods: NEMA C-face mounting or base mounting. 2. Determine Technical Requirements b. Base Mounting (2030 Configuration) 1. Select Configuration Washdown enclosed UniModule assemblies may be mounted as separate drive units driven from the prime mover by V-belts, chain and sprockets, couplings, timing belts and other standard power transmission components. a. NEMA C-face Mounting (1020 and 1040 Configurations) Based on the NEMA C-face frame size of...

Open the catalog to page 3
EUM-W Series Enclosed UniModule - 4

EUM-W Series Enclosed UniModule a. Heat Dissipation Sizing Friction surfaces slip during the initial period of engagement and, as a result, heat is generated. The clutch/brake selected must have a heat dissipation rating greater than the heat generated by the application. Therefore, in high inertia or high cycle rate applications, it is necessary to check the heat dissipation carefully. Inertia, speed and cycle rate are the required parameters. Heat dissipation requirement is calculated as follows: Compare the calculated heat generated in the application to the unit ratings using the heat...

Open the catalog to page 4
EUM-W Series Enclosed UniModule - 5

EUM-W Series Enclosed UniModule Specifications UniModule Size NEMA Frame Size 3. Select Options Accessories Warner Electric Enclosed Washdown UniModules can be fitted with several accessories to extend their capacity and ease of mounting. Conduit Box NEMA 4 and UL listed, available in standard and washdown versions. Mounting Brackets Two styles of mounting brackets are available for simplified installation. The base mount is used with the 2030 configuration. A motor mount is also available and provides sturdy support for a 1020 or 1040 combination with motor. (Optional) Motor Mount (M) F...

Open the catalog to page 5
EUM-W Series Enclosed UniModule - 6

EUM-W Series Enclosed UniModule Selection and Ordering Information Part Numbers Model No. Voltage 1020 Configuration – Washdown EUM-W 2030 Configuration – Washdown EUM-W Motor or Reducer Mounted Simply combine the size number with the configuration of the required UniModule. Specify voltage. See chart for specific part numbers. Order optional conduit box if desired. Example EUM180-W 90 Volt Brake Motor Clutch Size Base Mounted Simply combine the size number with the configuration of the required UniModule. Specify voltage. See chart for specific part numbers. Order optional conduit box if...

Open the catalog to page 6
EUM-W Series Enclosed UniModule - 7

EUM-W Series Enclosed UniModule EUM-W-1020 Clutch/Brake Combination Note: Washdown UniModules (EUM-W) do not have a finned housing. Dimensions Size All dimensions are nominal, unless otherwise noted. A Specifications UniModule Size NEMA Frame Size For NEMA standard frame dimensions, see page 187.

Open the catalog to page 7
EUM-W Series Enclosed UniModule - 8

EUM-W Series Enclosed UniModule EUM-W-2030 Clutch/Brake Combination–Base Mounted 20 Brake Optional Base Mount Note: Washdown UniModules (EUM-W) do not have a finned housing. All dimensions are nominal, unless otherwise noted. Specifications UniModule Size NEMA Frame Size For NEMA standard frame dimensions, see page 187.

Open the catalog to page 8

All WARNER ELECTRIC catalogs and technical brochures

  1. WSC Series

    6 Pages

  2. UM Series

    10 Pages

  3. EUM Series

    10 Pages

  4. UM-C Series

    7 Pages

  5. UM-W Series

    8 Pages

  6. EM series

    16 Pages

  7. EB series

    6 Pages

  8. EC series

    7 Pages

  9. MTB series

    10 Pages

  10. ATT series

    6 Pages

  11. TB series

    4 Pages

  12. CB series

    9 Pages

Archived catalogs

  1. General Catalog

    956 Pages