Product Description
The portable air conditioners AC20N and AC26N are designed for single-room cooling, featuring ventilation and dehumidifying functions. They use R290 refrigerant, which is environmentally friendly but highly flammable, requiring special precautions.
Safety Instructions
The appliance is intended for use by trained individuals and can be operated by children over 8 years under supervision. It must be used with R290 refrigerant only, and any servicing should be performed by qualified technicians. Safety measures include avoiding open flames, ensuring proper ventilation, and using original spare parts.
Product Overview
Key features include a high capacity, compact design, LED display, electronic control with timer, sleep mode, self-evaporating system, and remote control. Technical specifications vary slightly between models AC20N and AC26N, with differences in cooling and heating capacities.
Installation
The unit should be placed on a flat surface with adequate clearance for air circulation. It requires an exhaust hose connection to the outside. Installation should avoid heat sources, direct sunlight, and areas with poor ventilation.
Operation
The control panel includes functions for power, mode selection, fan speed, temperature adjustment, timer, sleep mode, and a child-proof lock. Proper setup of the exhaust hose is crucial for efficient operation.
Cleaning and Care
Regular maintenance involves cleaning the air filter and ensuring the drainage system is functioning. The unit should be disconnected from the power source during cleaning.
Troubleshooting
Common issues include inadequate cooling, water leakage, and unusual noises. Solutions involve checking the power supply, ensuring proper installation, and cleaning filters.
Decommissioning
Proper disposal of the unit involves following local regulations for refrigerant handling and recycling.
Operation Modes
The unit features five modes: Fan, Cool, Heat, Dehumidifier, and Sleep. Each mode is activated by pressing the MODE button until the desired indicator lights up. Temperature and fan speed adjustments are available in Cool and Heat modes, while Dehumidifier mode requires a drainage hose connection.
Remote Control
The remote control allows for easy operation of the unit, including mode selection and temperature adjustments.
Timer Setting
The timer can be set for 1 to 24 hours, allowing the unit to turn on or off automatically.
Automatic Defrost
The unit automatically defrosts if ice develops on the evaporator, ensuring efficient operation.
Overload Protection
A 3-minute delay is implemented to protect the compressor after a power loss.
Drainage
Manual and continuous drainage options are available. Continuous drainage is recommended for high humidity conditions.
Cleaning and Maintenance
Regular cleaning of the air filter is necessary to maintain efficiency. The filter is removable and should be cleaned biweekly.
Coolant Handling
Proper handling and disposal of coolant are crucial to avoid environmental harm.
Troubleshooting
The document provides solutions for common issues such as non-operation, reduced capacity, water leakage, and error codes.
Decommissioning
Instructions for storage and disposal are provided, emphasizing the importance of drying the unit and proper disposal of electrical appliances.
Warranty
A 2-year warranty is offered, covering defects due to manufacturing but excluding damages from improper handling.
Specifications and Controls
The document outlines the controls and settings for a climate control device, including temperature adjustment (16°C to 32°C), timer settings, sleep mode, child lock, and LED display functions. The device can operate in cooling, heating, ventilation, and dehumidification modes.
Operating Procedures
To start or stop the device, press the POWER button. The MODE button allows selection between cooling, heating, ventilation, and dehumidification. In cooling mode, the temperature can be set between 16°C and 32°C. The fan speed can be adjusted, and the air direction can be manually controlled. Heating mode requires a drain hose for continuous operation. Ventilation mode circulates air without cooling, and dehumidification mode requires a drain connection.
Timer and Defrosting
The timer can be set for 1 to 24 hours. Automatic defrosting occurs when ambient temperatures are low, with specific conditions triggering the defrost cycle to prevent frost buildup on the evaporator.
Maintenance
Regular cleaning of the air filter is necessary to maintain airflow and system efficiency. The filter should be vacuumed and rinsed every two weeks. The refrigerant system requires careful handling to prevent leaks and environmental harm.
Troubleshooting
Common issues include power connection problems, water level indicators, and temperature settings. Solutions involve checking connections, emptying the drain pan, and ensuring proper mode and temperature settings. Error codes indicate specific faults like communication errors or sensor failures.
Storage and Disposal
For long-term storage, the device should be cleaned, dried, and stored upright in a dry, ventilated area. Disposal must comply with environmental regulations, avoiding refrigerant release into the atmosphere.
Warranty and Compliance
The product has a two-year warranty covering manufacturing defects, excluding damage from misuse or incorrect installation. It complies with EU directives, and disposal instructions align with environmental standards.
Environmental and Disposal Guidelines
The release of refrigerants into the atmosphere is strictly prohibited. Electrical appliances should not be disposed of in household waste. Instead, use municipal disposal and recycling facilities. Contact your local government for information on available options. Improper disposal can lead to hazardous substances entering groundwater and the food chain.
Warranty Period
The manufacturer guarantees the product's compliance with the design description if the installation and operating instructions are followed. The warranty period is two years from the date of purchase. If a defect due to manufacturing occurs within this period, the customer is entitled to repair or product replacement. Damages from improper handling, third-party damage, incorrect installation, or consequential damages are excluded from the warranty. Keep your purchase receipt as warranty services are only provided upon presentation of the receipt.
Conformity
Zhejiang Outun Electronic Co. Ltd. declares that the products comply with the following directives: Directive 2014/35/EU - Low Voltage Directive (electrical equipment). The CE conformity certificate can be accessed via the provided link.
Disposal Instructions According to DIRECTIVE 2002/96/CE
Old devices should not be disposed of in household waste. Consumers are legally required to dispose of old devices separately, for example, at a community collection point. This ensures proper recycling and avoids negative environmental impacts. The symbol indicates that this device is part of the recycling cycle. Dispose of packaging separately: cardboard and paper should go to waste paper, and films to the recycling collection.
General Information
All product and handling information corresponds to the current state of technology and is based on the company's knowledge at the time of printing. Changes, errors, and printing mistakes do not entitle the customer to compensation. The terms and conditions of warm-on GmbH apply. The company reserves the right to make technical changes without prior notice.
Contact Information
Importer: warm-on GmbH, i_Park Tauberfranken 18, D-97922 Lauda-Königshofen, Germany.
Phone: +49 (0)9343-9809061 (Customer Service).
Manufacturer: Zhejiang Oulun Electronic Co. Ltd., No.17, Tangmei Road, Economic Development Zone, Linping District, Hangzhou, P.R. China.
See more

Catalog excerpts

Warm-on Local Air Conditionner - Owners Manual-1

Portable air conditioner AC20N white Portable air conditioner AC26N white Original instructions Cooling & Heating (With R290 refrigerant)

 Open the catalog to page 1
Warm-on Local Air Conditionner - Owners Manual-2

READ AND SAVE THESE INSTRUCTIONS CONTENT: 1. BEFORE YOU BEGIN 2. FOR YOUR SAFETY 3. PRODUCT OVERVIEW 4. INSTALLATION 5. OPERATION 6. CLEANING AND CARE 7. TROUBLESHOOTING 8. DECOMMISSIONING

 Open the catalog to page 2
Warm-on Local Air Conditionner - Owners Manual-3

EN 1.1 PRODUCT DESCRIPTION Our powerful portable air conditioners are great its a suggestion cooling solutions for single rooms, creating a comfortable atmosphere in your space. It also has ventilation and dehumidifying function for circulating air and removal of moisture. They are self-contained systems that do not require any permanent installation allowing you to move to the space in which it is mostly needed. They are commonly used in kitchen, temporary accomodation, computer rooms, garages, and many other places where installation of Air-conditioner Outdoor Unit is limited. The environmentally...

 Open the catalog to page 3
Warm-on Local Air Conditionner - Owners Manual-4

THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY • This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction, concerning use of the appliance in a safe way and understand the potential risk. Children shall not play with the appliance. Cleaning and user maintenance shall be made by instructed...

 Open the catalog to page 4
Warm-on Local Air Conditionner - Owners Manual-5

YOUR PERSONAL SAFETY FIRST! OUT LIABILITY! A PLEASE READ THIS MANUAL CAREFULLY. BE AWARE ABOUTTHE WORKFLOW WHEN STARTING THE WARNING SERVICE. 2.1 OPERATIONAL PRECAUTIONS WARNING - TO REDUCE THE RISK OF FIRE; ELECTRIC SCHOK OR INJURY TO PERSONNEL AND ENVIRONMENT: • If the main Lead is damaged, it must be replaced by the manufacturer, its service agent or other qualified persons in order to avoid a hazard. • The portable air conditioner needs to be disconnected from power source during service. • Check identification plate! Operating voltage, electric demand and frequency should correspond with...

 Open the catalog to page 5
Warm-on Local Air Conditionner - Owners Manual-6

Place portable air conditioner in safe distance from open fire, potentially inflameable or explosive atmosphere. Consider for installation national standards. Use for support of defrosting process or cleaning only recommended items by the manufacturer. The unit shall be stored in a room without continuously operation sources (e.g: open flames, an operating gas appliance or an operating electric heater). Portable air conditioner should be stored without risk of damage. Never piece or burn unit! Consider inodorousness of refrigerants! Pipe-work shall be protected from physical damage and shall...

 Open the catalog to page 6
Warm-on Local Air Conditionner - Owners Manual-7

2.2 SAFETY PRECAUTIONS ON SERVICING Please follow these warnings when to undertake the following when servicing an portable air conditioner with R290. 2.2.1 Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure, that the risk of ignition is minimized. For repair of the refrigerating system, the following precautions shall be cinternalised prior to execution of service work. 2.2.2 Work procedure Work shall be executed following the instruction for minimising risk caused by flammable gas or vapor in working area during service....

 Open the catalog to page 7
Warm-on Local Air Conditionner - Owners Manual-8

2.2.8 Checks of refrigeration equipment Where electrical components are replaced it need to be ensured compatibility to manufacturers specifications. Exclusively manufacturer’s coolant maintainance and service guidelines need to be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable coolants: – The charge size is in accordance with the room size within which the coolant containing parts are installed; – The ventilation machinery and outlets are operating adequately and are not obstructed;...

 Open the catalog to page 8
Warm-on Local Air Conditionner - Owners Manual-9

Note: The appearance is only for reference. Please see the real product for detailed information.

 Open the catalog to page 9
Warm-on Local Air Conditionner - Owners Manual-10

• High capacity and compact design with fan, cooling and dehumidifying function • Temperature setting and display • LED digital display • Electronic control with built-in timer, sleep mode • Self-evaporating system for better efficiency • Auto shut-off off when tank full • Automatic restart in the event of power outage • Auto defrosting function at low ambient temperatures • Remote control • 2- speed fan • Casters for easy mobility

 Open the catalog to page 10
Warm-on Local Air Conditionner - Owners Manual-11

4.1 UNPACKING • Open cardboard box and uncase portable air conditioner. • After unpacking the device, Look for damages or scratches. • Accessories: • 1. Exhaust hose

 Open the catalog to page 11
Warm-on Local Air Conditionner - Owners Manual-12

4.2 CHOOSE YOUR LOCATION For safety reason, set unit in an upright position and allow 24 hours rest for acclimation. Place the unit on a flat, level surface. Ensure distance to, e.g. walls, circumferentially by 50cm for excellent air circulation. Never operate close to walls, curtains, or other objects, that may block air circulation. Keep the air inlet and outlet free of obstacles. Never install the unit where it could be subject to: • Heat sources such as radiators, heat registers, stoves or other products that products produces heat. Direct sunlight Mechanical vibration or shock Excessive...

 Open the catalog to page 12
Warm-on Local Air Conditionner - Owners Manual-13

4.3 COUPLING OF EXHAUST HOSE The portable air conditioner needs a connection to outside the room for escape of exhaust air. If contains waste heat and moisture. Replacement or extension of exhaust hose will decrease efficiency an shutdown of unit (lossing backpressure). Step 1: Connect the hose connector to one end of the exhaust hose. Step 2: Connect the windows kit adapter to the other end of the exhaust hose. Step 3: xtend the adjustable window kit the length of your window. Connect the E exhaust hose to the window kit.

 Open the catalog to page 13
Warm-on Local Air Conditionner - Owners Manual-14

Step 4: lose your window to secure the kit in place. The window kit need a tight fit. C Secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency. Step 5: Connect hose adapter to the exhaust air outlet of unit on the backside. Step 6: djustment of flexible exhaust hose: Make sure a distance between the unit and A the window of more than 70cm. Distance between exhaust hose and florr should be > 90cm. Avoid any in hose. Place connector of mains (AC) near an socket outlet. Pay attention...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.