1. Catalogs
  2. WALVOIL
  3. HC-M50 (Standard Version)
video corpo

HC-M50 (Standard Version)

HC-M50 (Standard Version)
1 / 40 PagesView full catalog

HC-M50 (Standard Version)

Product catalog summary
Introduction
The HC-M50 monoblock valve by Hydrocontrol S.p.A. is designed for mobile equipment applications, featuring a symmetric valve body for flexible spool control. It supports parallel and tandem circuits and includes integrated functions like electric load limit and solenoid dump valve, enhancing versatility.
General Specifications
The document provides conversion factors for metric and British systems, detailing units for length, mass, force, volume, and pressure. It specifies fluid compatibility, temperature ranges, and gasket types for different fluids, including mineral oil and water-based solutions.
Standard Working Conditions
The HC-M50 operates at a nominal flow rate of 50 l/min (14.5 GPM) and a pressure rate of 350 bar (5000 psi). It functions within a temperature range of -25°C to +80°C and supports kinematic viscosity from 10 to 460 mm²/s. The contamination level is specified as 19/16 ISO 4406, with a filtration level of β 10 > 75.
Technical Specifications
The valve can have 1 to 7 working sections, with a spool stroke of 5.5 mm and a spool pitch of 35 mm. Details on ordering modalities, dimensions, and hydraulic specifications, including parallel and parallel-tandem circuit configurations, are provided.
Order Modality
Ordering involves specifying the monoblock type, inlet arrangement, work section arrangement, and outlet arrangement. Each section's configuration must be repeated for every work section in the monoblock.
Dimensions
The HC-M50 family is divided into four model categories based on circuit type and auxiliary valve presence. Standard thread sizes for ports are provided, with variable dimensions for different model types.
Hydraulic Specifications
The document describes the operation of parallel and parallel-tandem circuits, explaining how oil flow is directed to service ports A or B and how multiple spools can be actuated simultaneously.
Specifications and Dimensions
Specifications and dimensions for various hydraulic components are outlined, with a maximum pressure (P max) of 350 bar. Dimensions are provided in millimeters for different configurations.
Clamping Torque
The clamping torque for components is specified as 4 - 6 Nm, consistent across different configurations.
Flow Inhibition
Flow inhibition is described for ports A and B, with specific configurations inhibiting flow on either port A or B.
Ordering Codes
Various ordering codes are provided for different configurations of load limits and control types, including dual control and rotated configurations.
Electrical Specifications
Electrical specifications for load limit kits include voltage, current, and protection degree (IP 65), with recommendations for connecting inductive loads.
Electrohydraulic Control
Specifications for electrohydraulic control systems include maximum inlet pressure, reduced pressure, and back pressure. ON-OFF and proportional control systems are described, with specific ordering codes and configurations.
Auxiliary Valves
Information on auxiliary valves, such as antishock and anticavitation valves, is provided, including setting ranges and ordering codes.
Outlet Arrangement
Details on outlet arrangements for monoblock valves specify configurations for outlets on the top or sides.
Monoblock Valve Identification and Specifications
1. Outlet Arrangement
Classification of monoblock valves with two outlets is provided, detailing the arrangement of ports (P and T) on the valve body, identified by specific codes like MJK and MJL.
2. Tandem Circuit Identification
Three configurations for tandem circuits in monoblocks are described, requiring a special valve body for each configuration.
3. Lever Identification
Levers are classified by length and type, with ordering codes for levers with knobs and joystick control.
4. Installation and Maintenance
General clamping torque specifications are provided for various components, with specific torque values listed.
5. Product Identification
Each HC-M50 monoblock valve includes an identification plate with a serial number and ordering code.
See more

Catalog excerpts

HC-M50 (Standard Version)-1

Monoblock valve Distributore monoblocco

 Open the catalog to page 1
HC-M50 (Standard Version)-2

^_ J un Hydrocontrol S.p.a. reserves the right to introduce changes in any moment without ||l/QI fj obligation of prior notice componenti idrodinamici e senza I'obbligo di preavviso" WITH QUALITY MANAGEMENT COMPANY WITH ENVIRONMENTAL MANAGEMENT

 Open the catalog to page 2
HC-M50 (Standard Version)-3

Universal products and solutions for Mobile applications Prodotti e soluzioni universali per Macchine Mobili The monoblock valve HC-M50 has been made by Hydrocontrol S.p.A. in order to find solutions for different applications in mobile equipment. Il distributore monoblocco HC-M50 è stato realizzato da Hydrocontrol S.p.A. per soddisfare le esigenze di svariate applicazioni del settore mobile. HC-M50 has a symmetric valve body, that means better working features and the possibility to have spool control on each side. HC-M50 è costituito da un corpo simmetrico che oltre a garantire vantaggi funzionali,...

 Open the catalog to page 3
HC-M50 (Standard Version)-4

GENERAL SPECIFICATIONS CARATTERISTICHE GENERALI Standard working conditions Condizioni di lavoro standard • PORTATA NOMINALE . . . . . . . . . . . . . . . . . . . 50 l/min • KINEMATIC VISCOSITY. . . . . . . from 10 to 460 mm /s Technical specifications Caratteristiche tecniche • WORKING SECTION NUMBER . . . . . . . . . . . . . . . 1 - 7 • NUMERO SEZIONI DI LAVORO. . . . . . . . . . . . . . . 1 - 7 • CORSA DELLA SPOLA . . . . . . . . . . . . . . 5,5 + 5,5 mm Fluid compatybility TYPE OF FLUID (Oil and Solution) Mineral oil HPL (DIN 51524) Oil in water emulsion HFA(*) Water in oil emulsion HFB(*)...

 Open the catalog to page 4
HC-M50 (Standard Version)-5

General index Order modality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Hydraulic specifications . . . . . . . . . . . . . . . . . . . . . . . . . .8 Typical curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Inlet arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Spool type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Spool actuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Spool return action . ....

 Open the catalog to page 5
HC-M50 (Standard Version)-6

ORDER MODALITY Order example RICHIAMO CURSORE SPOOL RETURN ACTION KIT TAPPO DI CHIUSURA PLUG KIT VALVOLA DI MASSIMA DIRETTA DIRECT ACTING PRESSURE RELIEF VALVE CURSORE SPOOL KIT TAPPO DI CHIUSURA PLUG KIT VALVOLA ANTIURTO ANTISHOCK VALVE COMANDO CURSORE SPOOL ACTUATION /1 = number of sections PV = body type code . . . . . . . . . . . . . . . . . . .page 6 /1 = numero sezioni PV = sigla che identifica il tipo di corpo . . . . .pag. 6 IL 201 = inlet side and valve type . . . . . . . . . .page 12 150 = setting IL 201 = lato entrata e tipologia valvola . . . . . .pag. 12 150 = taratura C: WORK SECTION...

 Open the catalog to page 6
HC-M50 (Standard Version)-7

ORDER MODALITY INLET ARRANGEMENT ALLESTIMENTO ENTRATA PRESSURE RELIEF VALVE - VALVOLA DI MASSIMA RELIEF VALVE PLUGGED - SEDE VALVOLA CON TAPPO SPOOL TYPE TIPOLOGIA CURSORE SPOOL ACTUATION COMANDO CURSORE SPOOL RETURN ACTION RICHIAMO CURSORE AUXILIARY VALVES VALVOLE AUSILIARIE It must be specified with M50 PV or M50 TV - Da specificare solo in presenza di M50 PV o M50 TV OUTLET ARRANGEMENT ALLESTIMENTO USCITA 2 OUTLETS (HPCO) - 2 USCITE (HPCO) TANDEM SECTION - SEZIONE TANDEM It must be specified with tandem circuit only - Da specificare solo in presenza di circuiti tandem MONOBLOCK THREAD - FILETTATURA...

 Open the catalog to page 7
HC-M50 (Standard Version)-8

Depending on the circuit type and on the auxiliary valves presence, find four different kinds of models: L’intera famiglia dei monoblocchi HC-M50 si suddivide in quattro distinte categorie di modelli a seconda della tipologia dei circuiti e a dell’impiego o meno delle valvole ausiliarie sulle sezioni: BASIC PARALLEL MONOBLOCK PARALLEL MONOBLOCK WITH AUXILIARY VALVES MONOBLOCCO PARALLELO BASE MONOBLOCCO PARALLELO CON VALVOLE BASIC TANDEM MONOBLOCK TANDEM MONOBLOCK WITH AUXILIARY VALVES MONOBLOCCO TANDEM BASE MONOBLOCCO TANDEM CON VALVOLE Standard thread Filettature standard PORTS UTILIZZI thread...

 Open the catalog to page 8
HC-M50 (Standard Version)-9

HC-M50 with auxiliary valves - HC-M50 con valvole VARIABIL DIMENSIONS (mm) - QUOTE VARIABILI (mm) Type - Tipo Fixing specifications - Caratteristiche fissaggio M50 PB - M50 TB N°3 drills diameter 8,5 (length 46 mm) N°3 fori diametro 8,5 (profondità 46 mm) Monoblock Valve - DISTRIBUTORE MONOBLOCCO M50 PV - M50 TV N°3 drills diameter 8,5 (length 63 mm) N°3 fori diametro 8,5 (profondità 63 mm)

 Open the catalog to page 9
HC-M50 (Standard Version)-10

HYDRAULIC SPECIFICATIONS SPECIFICHE IDRAULICHE Parallel circuit Circuito Parallelo When the spool is operated it intercepts the switch gallery by diverting the flow of oil to service port A or B. If two or more spools are actuated at the same time, the oil will power the service port that has the lower load by selecting the path with the least resistance; by throtting the spools, the flow of oil can be divided between two or more service ports. Il cursore quando viene azionato, intercetta il canale di libera circolazione deviando il flusso d’olio agli utilizzi A o B. Se due o più cursori vengono...

 Open the catalog to page 10
HC-M50 (Standard Version)-11

HYDRAULIC SPECIFICATIONS Carry-over connection (HPCO) SPECIFICHE IDRAULICHE Collegamento carry-over (HPCO) This option, available on all HC-M50, allows the monoblock to feed a second valve, by extending the free flow channel. In this configuration, the valve needs a separated port for the connection to tank. Questa opzione, di serie sui monoblocchi HC-M50, permette il prolungamento del canale di libera circolazione all’esterno, alimentando così un secondo distributore. Il distributore così configurato necessita di uno scarico per le utenze. It is possible to transform monoblock from standard...

 Open the catalog to page 11
HC-M50 (Standard Version)-12

TYPICAL CURVES CURVE CARATTERISTICHE NOTE: indicated values have been tested with M50 PB monoblock and W001A spools. NOTA: i valori indicati sono stati rilevati con un monoblocco M50 PB e cursori W001A. Monoblock Valve - DISTRIBUTORE MONOBLOCCO

 Open the catalog to page 12
HC-M50 (Standard Version)-13

TYPICAL CURVES Relief valve curve CURVE CARATTERISTICHE Curva valvola di massima Campi di taratura - Setting ranges (A) = 20 / 110 (bar) (B) = 111 / 220 (bar) (C) = 221 / 350 (bar) Antishock valve curve Curva valvola antiurto Campi di taratura - Setting ranges (A) = 20/120 (passaggio - at full flow) (B) = 121/150 (passaggio - at full flow) (C) = 151/250 (passaggio - at full flow) 96-A / 220-A (apertura - at min. flow) (D) = 251/350 (passaggio - at full flow) 221-A / 380-A (apertura - at min. flow) Anticavitation valve curve Monoblock Valve - DISTRIBUTORE MONOBLOCCO Curva valvola anticavitazione...

 Open the catalog to page 13

All WALVOIL catalogs and technical brochures

  1. HC-SVM

    24  Pages

  2. HC-FL50

    2  Pages

  3. HC-M25

    2  Pages

  4. HC-SK6

    2  Pages

  5. HC-TR55

    36  Pages

  6. HC-D10

    36  Pages

  7. HC-M45

    36  Pages

  8. HC-NVD2

    2  Pages

  9. HC-MV99

    36  Pages

  10. HC-D4L

    1  Page

  11. HC-D3L

    1  Page

  12. HC-D6

    52  Pages

  13. HC-D4

    56  Pages

  14. HC-D3M

    52  Pages

  15. HC-D3

    52  Pages

  16. HC-D9

    40  Pages

  17. HC-SVM/SVE

    24  Pages

  18. HC - FL 50

    2  Pages

  19. HC - M 25

    2  Pages

  20. HC - SK 6

    2  Pages

  21. HC-BV50

    36  Pages

  22. product range

    178  Pages

  23. HC -TR55

    36  Pages

  24. HC -M50

    40  Pages

  25. HC -D10

    36  Pages

  26. catalog

    96  Pages

  27. Flow sharing

    20  Pages

  28. data sheet

    40  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.