WPH/WDP
4Pages

{{requestButtons}}

Catalog excerpts

WPH/WDP - 1

pH/ORP Controllers Metering Pumps The E-Class is the most innovative and comprehensive metering pump product line in the world. Over 50 years of pump experience and a commitment to superior mechanical design has led to development of many industry firsts, including 360 stroke-per-minute technology, IP67 waterproof construction, and the world’s highest capacity solenoid metering pumps. CONTROL 1 = WPH: 2 powered on/off relays & 2 on/off dry contact relays & 1 dry contact dedicated alarm WDP: 4 powered on/off relays & 1 powered dedicated alarm relay 2 = WPH & WDP: 2 pulse proportional relays & 2 on/off dry contact relays & 1 dry contact dedicated alarm 4 = WDP: 4 pulse proportional outputs & 1 dry contact dedicated alarm WIND WebMaster® Industrial Water Controllers Walchem’s WebMaster Industrial (WIND) Controller sets a new standard for Industrial Water Treatment Controllers. WIND has a flexible multi-I/O platform, a wide range of analytical sensor measurement capabilities, and an extensive assortment of integrated communications and data handling features. VOLTAGE 1 = WPH/WDP410: 120 VAC, prewired, 6” pigtails to powered relays WPH/WDP420, WDP440: 20 ft. cables for E Class pumps 3 = WPH420: 120 VAC, prewired, 20 ft. cables with connectors for EW pumps 5 = Hardwired, cable glands OUTPUT N = No data output 4 = Single isolated 4-20 mA output 2 = Two 4-20 mA outputs WPH OPTIONS 1 = Prewired preamp with 10 ft. cable (electrode not included. Electrode should have BNC connector) 2 = Submersion flat pH electrode w/integral preamp (WEL-PHF-21) 3 = In-line flat pH electrode w/integral preamp (WEL-PHF-22) includes 3/4” NPTF mounting tee 4 = In-line flat pH electrode w/integral preamp (WEL-PHF-22) includes 3/4” flow switch manifold & ‘U’ adapter mounted on polypro panel 4T=In-line flat pH electrode with ATC and integral preamp (WEL-PHF-12), 3/4” flow switch manifold & ‘U’ adapter mounted on polypro panel 5= Submersion ORP electrode w/integral preamp (WEL-MVF-21) 6 = In-line ORP electrode w/integral preamp (WEL-MVF-22), includes 3/4” NPTF mounting tee 6R= In-line rod style ORP electrode w/integral preamp (WEL-MVR-22), includes 3/4” NPTF mounting tee 7 = In-line ORP electrode w/integral preamp (WEL-MVF-22), 3/4” flow switch manifold and ‘U’ adapter mounted on polypro panel 7R= In-line rod style ORP electrode w / integral preamp (WEL-MVR-22), 3/4” flow switch manifold and ‘U’ adapter mounted on polypro panel WDP OPTIONS 2 = 2 WEL submersion style flat pH electrodes (without auto temp comp) 5 = 2 WEL submersion style ORP electrode 6 = 1 WEL submersion style flat pH electrode (without auto temp comp) & 1 WEL submersion ORP electrode 7 = 1 WEL in-line style flat pH electrode (without auto temp comp, tee included) & 1 WEL in-line ORP electrode (tee included) 8 = Flow switch manifold with 2 WEL in-line electrodes; 1 pH (without auto temp comp) & 1 ORP mounted on 19” x 24” polypropylene panel 8T=Identical to option #8 above, with auto temp comp USB FEATURES U = Integrated datalogging, event/reset logging, and configuration file import/export Agency Certifications Safety UL 61010-1:2012 3rd Ed. CSA C22.2 No. 61010-1:2012 3rd Ed. IEC 61010-1:2010 3rd Ed. EN 61010-1:2010 3rd Ed. EMC IEC 61326-1:2005 EN 61326-1:2006 Note: For EN61000-4-6 & EN61000-4-3 the controller met performance criteria B. *Class A equipment: Equipment suitable for use in establishments other than domestic, and those directly connected to a low voltage (100-240 VAC) power supply network which supplies buildings used for domestic purposes. WPH/WDP400 Series The WPH/WDP400 Series pH/ORP on-line process controllers are designed for a broad range of industrial, commercial, and municipal water treatment applications. WPH/WDP controllers are easily configured to accurately measure pH or mV (ORP) values from Walchem’s WEL and WDS differential combination electrodes, or any conventional combination electrode. A versatile output configuration allows you to program up to four outputs in a variety of control modes. Select from on/off mechanical relays or pulse proportional control for direct connection to metering pumps. The easyto-use menu format and pre-wired, pre-mounted panel system options make set-up and installation quick and simple. Integrated datalogging is available to validate system performance. A USB memory stick is all that’s needed to extract data and event logs that include electrode measurements, temperature and relay status. Download log files from the USB stick to a PC at your convenience. It couldn’t be easier! Summary of Key Benefits Dual Input Reduces Cost Dual pH or ORP electrode inputs allow one controller to take the place of two, reducing cost and space requirements, and simplifying installation. Versatility for a Broad Range of Applications Select from pH or ORP measurements and from five output options. Use In-Range to control a solenoid valve to dump a batch treatment tank when measurement value is within limits, or program for Out-ofRange Alarm in waste treatment applications when the measurement value is too high or low. Ideal for Harsh Environments The NEMA 4X enclosure, combined with Walchem’s WEL and WDS electrodes, provides a waterproof system with no BNC connectors exposed to wet or corrosive environments. Walchem integrates its advanced sensing, instrumentation, fluid pumping and communications technologies to deliver reliable and innovative solutions to the global water treatment market. Our in-house engineering is driven by quality, technology and innovation. For more information on the entire Walchem product line, visit: www.walchem.com 180459.I May 2014 Walchem, Iwaki America Inc. Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA Phone: 508-429-1110 www.walchem.com Built-in Safety Features Programmable output limit timers prevent run-away chemical addition. Digital Interlock Input may be used from a flow switch or level input to prevent chemical addition based on a stagnant sample, or control of an empty batch tank. Simple, Integrated Data Collection Download stored data from the controller to a USB stick with the press of a button. Use the data to simply and easily validate system performance, document compliance, and reduce liability. The data and event logs show pH/ORP and temperature values, as well as accumul

Open the catalog to page 1

All Walchem catalogs and technical brochures

  1. ADV series

    2 Pages

  2. WECT/WEDT

    4 Pages

  3. WCT/WDT

    4 Pages

  4. EJ

    2 Pages

  5. W100P

    4 Pages

  6. W600

    4 Pages

  7. HRP Series

    2 Pages

  8. WCU/WNI410

    4 Pages

  9. WDIS410

    4 Pages

  10. Paddlewheel

    2 Pages

  11. Level Sensor

    2 Pages