1. Catalogs
  2. Walchem
  3. W600 Controller

W600 Controller

W600 Controller

W600 Controller

Product catalog summary
Overview of W600 Series Controllers
The W600 Series Controllers are designed for water treatment applications, featuring a large touchscreen display with icon-based programming for easy setup. They support universal sensor input, optional dual analog input, multiple languages, and six control outputs. The controllers are available in a wall-mount package for easy installation.
Key Features
  • On-screen graphing of sensor values and control output status.
  • Flexible relay functions including On/Off Setpoint and Time Proportional Control.
  • Data logging and emailing capabilities for alarms and reports.
  • Ethernet option for remote access.
Specifications
  • Power: 100-240 VAC, 50 or 60 Hz, 7A max.
  • Outputs: Powered and dry contact mechanical relays, pulse outputs, and 4-20 mA analog outputs.
  • Enclosure: Polycarbonate, NEMA 4X (IP65) rating.
  • Display: 320 x 240 pixel monochrome backlit touchscreen.
  • Temperature Range: -4 to 131°F (-20 to 55°C) for operation, -4 to 176°F (-20 to 80°C) for storage.
Measurement Performance
  • Conductivity: Ranges from 0-300 µS/cm to 0-300,000 µS/cm.
  • pH: Range from -2 to 16 pH units.
  • ORP: Range from -1500 to 1500 mV.
  • Temperature: 23 to 500°F (-5 to 260°C).
Sensor Options
  • Cooling Tower Sensors: Inline and high-pressure contacting conductivity configurations.
  • Boiler Sensors: Options with and without ATC, different cell constants, and cable lengths.
  • pH/ORP Sensors: Available with low and high-pressure manifolds.
  • Disinfection Sensors: Configurations for single and dual flow cells.
Agency Certifications
  • Safety: UL, CSA, IEC, and EN standards.
  • EMC: IEC and EN standards.
Specifications
1. Cell Contacting Conductivity: Ranges from 0-30,000 µS/cm to 0-300,000 µS/cm with accuracy of ±1% of reading.
2. pH Measurement: Range from -2 to 16 pH units with precision of 0.01 pH units.
3. ORP and Disinfection Sensors: Range from -1500 to 1500 mV and -2000 to 1500 mV respectively, with accuracy of ±1 mV.
4. Electrodeless Conductivity: Ranges from 500 to 2,000,000 µS/cm with accuracy of ±1% of reading.
5. Temperature: Range from 23 to 500°F (-5 to 260°C) with accuracy of ±1% of reading.
Mechanical Specifications
1. Sensor Pressure and Temperature: Varies by sensor type, e.g., Electrodeless conductivity sensors operate at 0-140 psi and 32-190°F.
2. Materials: Includes CPVC, PEEK, 316 SS, and others depending on sensor type.
3. Process Connections: Various NPTM and NPTF sizes for different sensors.
Sensor Input and Output
1. Sensor Input Signals: Supports various conductivity, pH, ORP, and disinfection sensors.
2. Analog and Digital Inputs: Supports multiple configurations with isolated power supplies.
3. Digital Input Signals: Includes state-type, low-speed, and high-speed counter-type inputs.
Dimensions and Tolerances
Detailed dimensions provided for various models with specific tolerances.
Key Benefits of W600 Series Controllers
1. Display and Programming: Large touchscreen with icon-based programming.
2. Flexibility: Universal sensor input and multiple language support.
3. Control Outputs: Six control outputs with various activation modes.
4. Datalogging and Remote Access: Ethernet option for remote access and emailing of reports.
Ordering Information
Details on various configurations and options for W600 series controllers, including sensor types and relay configurations.
See more

Catalog excerpts

W600 Controller-1

Ordering Information WCT (Cooling Tower) WBL (Boiler) WPH (pH) WDS (Disinfection) WCN (Conductivity) Conductivity, pH/ORP & Disinfection Relays/Wiring Input Cards 6 powered relays, Hardwired 6 powered relays, Prewired with USA cords and pigtails 6 powered relays, Prewired with DIN power cord, no pigtails 2 powered 4 dry relays, Hardwired 2 powered 4 dry relays, Prewired with USA cord and 2 pigtails 2 powered 4 dry relays, Prewired with DIN power cord, no pigtails 2 opto 4 dry relays, Hardwired 2 opto 4 dry relays, Prewired with USA cord and two 20 ft. pulse cables 2 opto 4 dry relays, Prewired with DIN power cord, no pigtails 4 opto 2 dry relays, Hardwired 4 opto 2 dry relays, Prewired with USA cord and four 20 ft. pulse cables 4 opto 2 dry relays, Prewired with DIN power cord, no pigtails No sensor input cards One sensor input card Two sensor input cards One dual analog input card Two dual analog input cards One sensor input card and one analog input card No analog outputs One dual isolated analog output card No Ethernet Ethernet card WCT Cooling Tower Sensors No sensor Inline graphite contacting conductivity Graphite contacting conductivity + Flow Switch manifold on panel High pressure contacting conductivity High pressure contacting conductivity + Flow Switch manifold on panel Inline 316SS contacting conductivity 316SS contacting conductivity + Flow Switch manifold on panel Inline electrodeless conductivity Electrodeless conductivity + Flow Switch manifold on panel Graphite contacting conductivity + Flow Switch manifold on panel + WEL-PHF no ATC Graphite contacting conductivity + Flow Switch manifold on panel + WEL-MVR no ATC Graphite contacting conductivity + Flow Switch manifold on panel + WEL-MVF no ATC Graphite contacting conductivity + Flow Switch manifold on panel + LD 316SS contacting conductivity + Flow Switch manifold on panel + WEL-PHF no ATC 316SS contacting conductivity + Flow Switch manifold on panel + WEL-MVR no ATC 316SS contacting conductivity + Flow Switch manifold on panel + WEL-MVF no ATC 316SS contacting conductivity + Flow Switch manifold on panel + LD High pressure contacting conductivity + Flow Switch manifold on panel + pH and 190783 High pressure contacting conductivity + Flow Switch manifold on panel + ORP and 190783 Electrodeless conductivity + Flow Switch manifold on panel + WEL-PHF no ATC Electrodeless conductivity + Flow Switch manifold on panel + WEL-MVR no ATC Electrodeless conductivity + Flow Switch manifold on panel + WEL-MVF no ATC Electrodeless conductivity + Flow Switch manifold on panel + LD Analog Outputs NEW!! W600 Series Controllers WBL Boiler Sensors NN AN BN CN DN AA BB CC DD AB AC AD BC BD CD No sensor Boiler sensor with ATC, 250 psi, 1.0 cell constant, 20 ft. cable Boiler sensor without ATC, 250 psi, 1.0 cell constant, 20 ft. cable Condensate sensor with ATC, 200 psi, 0.1 cell constant, 10 ft. cable Boiler sensor with ATC, 250 psi, 10 cell constant, 20 ft. cable Two K=1.0 boiler sensors with ATC, 250 psi, 20 ft. cables Two K=1.0 boiler sensor without ATC, 250 psi, 20 ft. cables Two K=0.1 condensate sensors with ATC, 200 psi, 10 ft. cables Two K=10 Boiler sensors with ATC, 250 psi, 20 ft. cables K=1.0 boiler sensor with ATC and K=1.0 boiler sensor without ATC, 250 psi, 20 ft. cables K=1.0 boiler sensor with ATC, 20 ft. and K=0.1 condensate sensor with ATC, 250 psi, 10 ft. cable K=1.0 boiler sensor with ATC and K=10 boiler sensor with ATC, 250 psi, 20 ft. cables Boiler sensor without ATC, 20 ft. and condensate sensor with ATC, 10 ft. cable Boiler sensor without ATC and K=10 boiler sensor with ATC, 250 psi, 20 ft. cables Condensate sensor with ATC, 10 ft. cable and K=10 boiler sensor with ATC, 250 psi, 20 ft. cable No sensors or flow switch manifold Single low pressure manifold on panel** Single high pressure manifold on panel with 190783* Dual low pressure manifold on panel** Dual high pressure manifold on panel with two 190783* *Order 102029 pH and/or 102963 ORP electrodes separately **Order WEL electrode(s) and preamplifier housing(s) separately WDIS Disinfection Sensors/Manifold NN PN PX FN FF No sensors or flow switch manifold Single DIS manifold on panel* DIS manifold plus pH/ORP/cooling tower cond tee on panel** Single DIS flow cell/cable, no sensor* Two DIS flow cell/cable, no sensors* *Order disinfection sensor(s) separately **Order disinfection sensor and WEL electrode and preamplifier housing or cooling tower conductivity sensor separately NN No sensors or flow switch manifold* *Order conductivity sensor separately The W600 series provides reliable, flexible and powerful control for your water treatment program. Summary of Key Benefits Large touchscreen display with icon based programming makes setup easy Universal sensor input provides extraordinary flexibility; the same controller can be used with almost any type of sensor needed Optional dual analog (4-20 mA) input for Fluorometers or nearly any other process value Multiple language support allows simple setup no matter where your business takes you Six control outputs allow the controller to be used in more applications Economical wall-mount package for easy installation On-screen graphing of sensor values and control output status Complete flexibility in the function of each relay • On/Off Setpoint • Time Proportional Control • Pulse Proportional Control (when purchased with solid-state relays) • In-Range or Out-of-Range activation • Probe wash • Timer-based activation • Activation based upon the state of a contact closure • Timed activation triggered by a Water Contactor or Paddlewheel flow meter’s accumulated total flow • Activate with another output • Activate as a percent of another output’s on-time • Alarm • Spike Set Point • For Cooling Tower and Boiler applications: • Biocide Timer • Boiler blowdown on conductivity using intermittent sampling Datalogging Emailing Alarm messages, Datalog reports or System Summary reports Ethernet option for remote access via the Internet or LAN 180625.F Aug 2015 Walchem, Iwaki America Inc. | Five Boynton Road Hopping Brook Park | Holliston, MA 01746 USA | Phon

 Open the catalog to page 1

All Walchem catalogs and technical brochures

  1. ADV series

    2  Pages

  2. WPH/WDP

    4  Pages

  3. WECT/WEDT

    4  Pages

  4. WCT/WDT

    4  Pages

  5. EJ

    2  Pages

  6. W100P

    4  Pages

  7. W600

    4  Pages

  8. HRP Series

    2  Pages

  9. WCU/WNI410

    4  Pages

  10. WDIS410

    4  Pages

  11. Paddlewheel

    2  Pages

  12. Level Sensor

    2  Pages

  13. WIND Brochure

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.