1. Catalogs
  2. WAGO
  3. 2857-534 JUMPFLEX® Signal Conditioners

2857-534 JUMPFLEX® Signal Conditioners

2857-534 JUMPFLEX® Signal Conditioners

2857-534 JUMPFLEX® Signal Conditioners

Product catalog summary
Overview: The document provides technical specifications and configuration details for the WAGO JUMPFLEX® Signal Conditioner, specifically the TC Threshold Value Switch model 2857-534. This device is designed for monitoring and reporting signals from thermocouples with up to two switching thresholds.
Specifications:
  • Configuration: Can be configured via DIP switch, interface configuration software, app, or display.
  • Input: Supports thermocouple types J, K, E, R, N, S, T, B, S with a temperature range from -210 °C to +1372 °C depending on the type.
  • Output: Includes digital signal output and relay with changeover contact. Max switching voltage for digital output is supply voltage minus 0.3 V, and for relay output is 250 VAC.
  • General Specifications: Nominal supply voltage is 24 VDC with a range of 16.8 V to 31.2 V. Current consumption is ≤ 40 mA + IDO.
  • Environmental Requirements: Operating temperature range is -40 °C to +70 °C, and storage temperature range is -40 °C to +85 °C.
  • Safety and Protection: Features 3-way isolation with a test voltage of 4 kV AC.
  • Dimensions and Weight: Measures 12.5 x 107 x 110 mm and weighs 87 g.
Configuration Details:
  • DIP Switch Settings: Default settings include cold junction compensation ON, sensor type J, lower value 0 °C, upper value 100 °C, hysteresis 3 K, and rise/fall delay time 0 s.
  • Adjustability: DIP switches allow for configuration of sensor type, cold junction compensation, hysteresis, and delay times.
Standards and Approvals: Conforms to standards such as DIN EN 50178:1997, DIN EN 61010-1:2010, and others related to isolation and electromagnetic compatibility.
Contact Information: WAGO Kontakttechnik GmbH & Co. KG, Minden, Germany. Contact via phone or email for further inquiries.
See more

Catalog excerpts

2857-534 JUMPFLEX® Signal Conditioners-1

2857-534 JUMPFLEX® Signal Conditioners TC Threshold Value Switch Configuration via: Interface configuration software Configuration display Short description: WAGO's Thermocouple Threshold Value Switch for TC sensors monitors and reports signals of up to two switching thresholds. Features: • Both digital signal output and relay with changeover contact react to configured measuring range limits (switching ON/OFF delay and threshold value switch function configurable with up to two threshold values). • Adjustable software filter • Input/Output response simulation via configuration display • Safe 3-way isolation with 4 kV test voltage acc. to EN 61140 Technical Data Configuration: Configuration Input: Input signal Sensor types Temperature range Cold junction compensation Cold junction error Output: Output – Digital: Max. switching voltage Max. continuous current IDO Number of switching tresholds Configurable rise and fall delay time Output – Relay: Contact type Contact material Max. switching voltage Max. continuous current (terminal blocks in a row) Dielectric strength open contact (AC, 1 min) Pull-in/drop-out/bounce time typ. Number of switching tresholds Configurable rise and fall delay time WAGO Kontakttechnik GmbH & Co. KG Subject to design changes Pack. Unit JUMPFLEX® Signal Conditioner, for DIN 35 rail TC Threshold Value Switch Technical Data DIP switch, interface configuration software, interface configuration app, configuration display Thermocouples Thermocouple's type J, K, E, R, N, S, T, B, S Type J: -210 °C … +1200 °C Type K: -200 °C … +1372 °C On/Off (Default: On) 3 K (type 2 K) Supply voltage applied -0.3 V 100 mA (no internal restriction) 1 or 2 0 … 10 s (via DIP switch); 0 … 60 s (expanded) 1 changeover contact (1 u) AgNi (gold-plated) 250 VAC 6 A (up to 60 °C), 3 A (60 °C … 70 °C) 1 kVrms 8 ms / 4 ms / 8 ms 1 or 2 0 … 10 s (via DIP switch); 0 … 60 s (expanded) General specifications: Nominal supply voltage VS Supply voltage range Current consumption at 24 VDC Measurement error Temperature coefficient Environmental requirements: Ambient operating temperature Storage temperature Safety and protection: Test voltage (input/output/supply) Connection and type of mounting: Wire connection Cross sections Strip length Dimensions and weight: Dimensions (mm) W x H x L Weight Standards and approvals: Conformity marking Standards/Specifications Postfach 2880 - D-32385 Minden Hansastr. 27 - D-32423 Minden 4 kV AC, 50 Hz, 1 min. CAGE CLAMP® S (picoMAX® 5.0) solid/fine-stranded: 0.2 … 2.5 mm² / AWG 24 … 12 9 … 10 mm / 0.35 … 0.39 in 12.5 x 107 x 110 Height from upper-edge of DIN 35 rail 87 g 1 DIN EN 50178:1997 (Basic isolation); DIN EN 61010-1:2010; DIN EN 60664-1:2008; EN 61000-6-2; EN 61000-6-4 see pages 226 … 236

 Open the catalog to page 1
2857-534 JUMPFLEX® Signal Conditioners-2

DIP Switch S1 Sensor Type Thermocouple 1 Cold Junction Compensation Rise/Fall Delay Time Relay/ Digital Output (DO) DIP Switch S2 Lower Value 1 Upper Value Default Settings Cold Junction Compensation Sensor Type Lower Value Upper Value Rise/Fall Delay Time Relay/Digital Output (DO)

 Open the catalog to page 2

All WAGO catalogs and technical brochures

  1. 789-665

    5  Pages

  2. 752-8400

    3  Pages

  3. WAGO Marking

    92  Pages

  4. Setup unit

    1  Page

  5. KNX IP 1.1 US

    6  Pages

  6. Safety Flyer

    8  Pages

  7. PCB/MCS 12/13 GB

    636  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.