2857-534 JUMPFLEX® Signal Conditioners
1 / 2Pages

Catalog excerpts

2857-534 JUMPFLEX® Signal Conditioners - 1

2857-534 JUMPFLEX® Signal Conditioners TC Threshold Value Switch Configuration via: Interface configuration software Configuration display Short description: WAGO's Thermocouple Threshold Value Switch for TC sensors monitors and reports signals of up to two switching thresholds. Features: • Both digital signal output and relay with changeover contact react to configured measuring range limits (switching ON/OFF delay and threshold value switch function configurable with up to two threshold values). • Adjustable software filter • Input/Output response simulation via configuration display • Safe 3-way isolation with 4 kV test voltage acc. to EN 61140 Technical Data Configuration: Configuration Input: Input signal Sensor types Temperature range Cold junction compensation Cold junction error Output: Output – Digital: Max. switching voltage Max. continuous current IDO Number of switching tresholds Configurable rise and fall delay time Output – Relay: Contact type Contact material Max. switching voltage Max. continuous current (terminal blocks in a row) Dielectric strength open contact (AC, 1 min) Pull-in/drop-out/bounce time typ. Number of switching tresholds Configurable rise and fall delay time WAGO Kontakttechnik GmbH & Co. KG Subject to design changes Pack. Unit JUMPFLEX® Signal Conditioner, for DIN 35 rail TC Threshold Value Switch Technical Data DIP switch, interface configuration software, interface configuration app, configuration display Thermocouples Thermocouple's type J, K, E, R, N, S, T, B, S Type J: -210 °C … +1200 °C Type K: -200 °C … +1372 °C On/Off (Default: On) 3 K (type 2 K) Supply voltage applied -0.3 V 100 mA (no internal restriction) 1 or 2 0 … 10 s (via DIP switch); 0 … 60 s (expanded) 1 changeover contact (1 u) AgNi (gold-plated) 250 VAC 6 A (up to 60 °C), 3 A (60 °C … 70 °C) 1 kVrms 8 ms / 4 ms / 8 ms 1 or 2 0 … 10 s (via DIP switch); 0 … 60 s (expanded) General specifications: Nominal supply voltage VS Supply voltage range Current consumption at 24 VDC Measurement error Temperature coefficient Environmental requirements: Ambient operating temperature Storage temperature Safety and protection: Test voltage (input/output/supply) Connection and type of mounting: Wire connection Cross sections Strip length Dimensions and weight: Dimensions (mm) W x H x L Weight Standards and approvals: Conformity marking Standards/Specifications Postfach 2880 - D-32385 Minden Hansastr. 27 - D-32423 Minden 4 kV AC, 50 Hz, 1 min. CAGE CLAMP® S (picoMAX® 5.0) solid/fine-stranded: 0.2 … 2.5 mm² / AWG 24 … 12 9 … 10 mm / 0.35 … 0.39 in 12.5 x 107 x 110 Height from upper-edge of DIN 35 rail 87 g 1 DIN EN 50178:1997 (Basic isolation); DIN EN 61010-1:2010; DIN EN 60664-1:2008; EN 61000-6-2; EN 61000-6-4 see pages 226 … 236

Open the catalog to page 1
2857-534 JUMPFLEX® Signal Conditioners - 2

DIP Switch S1 Sensor Type Thermocouple 1 Cold Junction Compensation Rise/Fall Delay Time Relay/ Digital Output (DO) DIP Switch S2 Lower Value 1 Upper Value Default Settings Cold Junction Compensation Sensor Type Lower Value Upper Value Rise/Fall Delay Time Relay/Digital Output (DO)

Open the catalog to page 2

All WAGO catalogs and technical brochures

  1. 789-665

    5 Pages

  2. 752-8400

    3 Pages

  3. WAGO Marking

    92 Pages

  4. Setup unit

    1 Pages

  5. Safety Flyer

    8 Pages

Archived catalogs