Catalog excerpts
Product Range UPS - Systems Power Supply Protect/on serversystems, automat/on systems etc addition to our successful POWERMASTER S series with types S 1001 to S 3002. The POWERMASTER S 6000 is attractive not only due to its distinctive design, but also for its ex- treme flexibility. Wth its 90° rotatable display the system can be used as a standing device (tower) or as a 19-inch-rack. The device is also pre-equipped for wall mounting. The display can be removed and placed at a desired location apart from the rest of the system via an exten- sion cable. All POWERMASTER devices are based on the well-developed technology found in the JOVYTEC P series. POWERMASTER S series systems are distinguished by combination of this reliable technology with the compact design UPS systems fulfill the VFI-SS-111 protection class requirements with their online double con- version technology. They are equipped with a fan control unit, connected to the output of the UPS, and with a so-called PFC (Power Fac- tor Correction) that ensures sinusoidal power consumption. The output voltage is also sinuso- idal with all POWERMASTER systems. The standard series of the POWERMASTER S 6000 is designed for autonomy times of 9-90 mi- nutes at full load. POWERMASTER series UPS systems allow the selection between four different operating modes via operating panel: • Online Mode • Green Mode • Free Running Mode • Generator Mode. Display Panel The POWERMASTER S 6000 is equipped with an LC display with comprehensive display options for voltage, frequency, battery le- vel and load level and can be shown in five different languages. The configuration software that is included allows individual operating parameters to be adjusted. For example the output voltage can be set between 200 and 240 V or the automatic restart can be deactivated. Product Range UPS - Systems Technical Data: switch over noise level power factor autonomy time charging time power factor overload behaviour crest factor voltage failure overload switch over operation mode 230 V standard (208V/220 V/240 V selectable via panel) automatically adjusted by UPS-System 88 - 98 % depending on operation mode automatic overload switch-over by UPS-system real online operation VFI-SS-111 adjustable
Open the catalog to page 1Product Range Standard Equipment: self diagnostic at each starting of the UPS 4 different operation modes are selctable: Online-Mode, Generator-Mode, Free-Running-Mode, Green-Mode electronic manual emergency shutdown possible RS-232 interface light version of shutdown - software terminals for additional battery packs well - arranged and large LC-Display fan-unit with power control connection via terminal board for input / output / bypass power factor control für sinusoidal current consumption buzzer with reset button to acknowledge alarms or mains failure static and manual bypass manual...
Open the catalog to page 2All Wärtsilä JOVYATLAS GmbH catalogs and technical brochures
-
UPS-Software JUMP
4 Pages
-
UPC frequency converter
2 Pages
-
Train resistors
2 Pages
-
PROFIBUS
2 Pages
-
POWERMASTER S2002K / S3002K
2 Pages
-
PFC rectifier - GRP
2 Pages
-
ml - mobile load banks
2 Pages
-
mini load banks
2 Pages
-
KG007 Lamp rectifier
2 Pages
-
JST frequency converter
2 Pages
-
JSP 5000 Inverter
2 Pages
-
JOVYTEC P nt
2 Pages
-
JOVYSTAR plus
2 Pages
-
JOVYSTAR ocean
2 Pages
-
JOVYSTAR hp
2 Pages
-
JHL15 Handy Load Bank
2 Pages
-
HWS - Steel Grid Resistors
2 Pages
-
HPI Inverter
4 Pages
-
Earthing Resistor
4 Pages
-
Brake Resistors
2 Pages
-
Battery Supplied UPS Systems
2 Pages
-
JOVYTEC P
2 Pages
-
small load banks up to 20 kW
2 Pages
-
JOVYCUBE UPS - Leaflet
2 Pages
-
Mobile load bank type ML
2 Pages
-
UPS JOVYSTAR pro- Leaflet
2 Pages
-
switched-mode rectifier SRM
2 Pages
-
POWERMASTER S1001-S3002
2 Pages
-
JOVYTEC L
2 Pages
-
JOVYSTAR delta
2 Pages
-
JOVYLINE
2 Pages
-
steel-grid resistors
2 Pages
-
tube resistors
2 Pages
Archived catalogs
-
JOVYSTAR m
4 Pages
-
load banks for hire
4 Pages
-
small load banks up to 20 kW
4 Pages
-
load banks up to 1 MW
4 Pages
-
neutral grounding resistors
4 Pages
-
Summary of program
4 Pages
-
braking resistors
4 Pages
-
load banks up to 7.2 MW
4 Pages