JOVYSTAR plus
2Pages

{{requestButtons}}

Catalog excerpts

JOVYSTAR plus - 1

Product Range JOVYSTAR plus www.jovyatlas.de www.jovyatlas.de www.jovyatlas.de Power Supply Protection in the fields of process automation, networks & serversystems etc. JOVYSTAR plus Our JOVYSTAR plus UPS series features single phase systems up to 20 kVA and three-phase systems up to 40 kVA. The JOVYSTAR plus can be operated as a true online system (double conversion) or in standby mode in order to achieve the highest level of efficiency possible. UPS systems out of the JOVYSTAR plus series are equipped with a PFC rectifier using IGTB technology with a very large input voltage range and a power factor cos φ of nearly 1. More over that all systems of this type are equipped with a selfdiagnosis system and feature a very high dynamic during load changes. They also have a low noise level. The rectifier’s harmonic distortion (THDI) is rated at under 4%. This low THDI allows a smaller dimensioning of the emergency power generators than it‘s possible with standard rectifiers using thyristor technology. The battery lifetime can be significantly increased by using this digital rectifier. Active current sharing in parallel operation is a special feature of our JOVYSTAR plus systems. The parallel connection of up to 6 systems to create redundancy (n+1 operation) or to increase output is easily possible. With this innovative technology for digitalization using two 32 bit DSPs, not only the active power, but the reactive power as well, is factored into controlling the load distribution. All system data can be retrieved from a RS 232/USB interface – it can also be optionally transmitted via SNMP adapter, MODBUS adapter, PROFIBUS or other bus system. The battery can be integrated in the UPS encasing for short autonomy times. External design-fitted battery cabinets can be used for longer autonomy times. systems provide optimal energy supply to the connected equipment because a permanent, stable output voltage free from all grid-typical disturbing impulses, voltage peaks and voltage fluctuations is provided. Therefore critical equipment is supplied with secure voltage at all times. The IGBT rectifier integrated in the UPS system permanently feeds the inverter with controlled direct current and charges the battery. The inverter converts the direct current coming from the rectifier or battery into controlled alternating voltage using pulse width modulation. The JOVYSTAR plus inverter is absolutely shortcircuit-proof. All JOVYSTAR plus series UPS systems have an integrated static switch and manual bypass. The manual bypass can be used for the continual supply of the load during maintenance or malfunction of the UPS system. JOVYSTAR plus During online mode the JOVYSTAR plus series Leaflet-JOVYSTAR plus-E

Open the catalog to page 1
JOVYSTAR plus - 2

Product Range JOVYSTAR plus www.jovyatlas.de www.jovyatlas.de www.jovyatlas.de Technical Data:: JOVYSTAR plus single-phased / 10-20 kVA Dimensions wxhxd (mm) Weight (kg) without battery further autonomy times on request JOVYSTAR plus three-phased / 10-40 kVA JOVYSTAR plus 33-10-0 JOVYSTAR plus 33-20-0 JOVYSTAR plus 33-30-0 further autonomy times on request Technical Data JOVYSTAR plus three-phased / single-phased input voltage input frequency input power factor input current distortion factor number of battery cells battery- charging voltage Battery-cell-end voltage DC-ripple (disconnected...

Open the catalog to page 2

All Wärtsilä JOVYATLAS GmbH catalogs and technical brochures

  1. PROFIBUS

    2 Pages

  2. JOVYTEC P nt

    2 Pages

  3. JOVYSTAR hp

    2 Pages

  4. HPI Inverter

    4 Pages

  5. JOVYTEC P

    2 Pages

  6. JOVYTEC L

    2 Pages

  7. JOVYLINE

    2 Pages

Archived catalogs

  1. JOVYSTAR m

    4 Pages