TECHNICAL DATA POWER SUPPLY V317 FOR ELECTROMAGNETIC BRAKES TECHNISCHE DATEN ENERGIEVERSORGUNG V317 FÜR ELEKTROMAGNETISCHE BREMSEN

Open the catalog to page 1
Power Supply V317 for electromagnetic brakes : english / german - 3

TORQUE FOR HEAVY DUTIES

Open the catalog to page 3
Power Supply V317 for electromagnetic brakes : english / german - 4

POWER SUPPLY ENERGIEVERSORGUNG NEW! POWER SUPPLY V317 NEU: ENERGIEVERSORGUNG V317 POWER SUPPLY V317 FOR ELECTROMAGNETIC BRAKES ENERGIEVERSORGUNG V317 FÜR ELEKTROMAGNETISCHE BREMSEN V317 – Power Supply is a brand new VULKAN product, smaller and lighter, V317 is able to control any DC electromagnetic brake within its maximum current range. V317 current output operates in a closed loop system that allows better performance control and faster response of electromagnetic brakes, making operation safer and more agile. The electromagnetic brakes generally operate on two different levels of DC...

Open the catalog to page 4
Power Supply V317 for electromagnetic brakes : english / german - 5

POWER SUPPLY ENERGIEVERSORGUNG MAIN FEATURES HAUPTEIGENSCHAFTEN SUPPLY From 3-phase alternating current from grid power or generator unit 220 … 480 V AC +/–  5 % – 50/60 Hz, insensitivity to phase sequence. 1 QUELLE Drehstromnetz oder Generator 220 … 480 V AC +/–  5 % – 50/60 Hz, unempfindlich gegen Phasenfolge. 1 AIR-COOLING Natural with vertical airflow. LUFTSELBSTKÜHLUNG mit vertikalem Luftstrom. SERIAL INTERFACE Available with optional card. MODBUS protocol according to RS232-C standard and RS485 standard. SERIELLE SCHNITTSTELLE Auch mit optionaler Karte lieferbar. Protokoll MODBUS...

Open the catalog to page 5
Power Supply V317 for electromagnetic brakes : english / german - 6

POWER SUPPLY ENERGIEVERSORGUNG V317-40A LIST OF TECHNICAL DATA LISTE DER TECHNISCHEN DATEN Type Typ Brake Model Bremsentyp Coil Resistance Current per Brake Spulenwiderstand Betriebsstrom pro Bremse Output Voltage Ausgangsspannung Call / Economy (V) Abruf / Sparmodus (V) 1 Brake / 1 Bremse *It is not possible to connect two brakes in series for voltages less than 380 VCA (03 PHASE INPUT) VULKAN DRIVE TECH Recommended Input Circuit breaker (A) Empfohlener Eingangsstrom Schutzschalter (A) Ultra-rapid fuse (A) Sicherung superflink (A) Switch / MCCB (A) Schalter / MCCB (A) *Bei Spannungen unter...

Open the catalog to page 6
Power Supply V317 for electromagnetic brakes : english / german - 7

POWER SUPPLY ENERGIEVERSORGUNG Costumer Interfaces Kundenschnittstellen Power Supply Running Stromversorgung läuft 1 ODER 2 Bremsen in Reihe geschaltet Brake Coil Bremsenspule Brake Coil Bremsenspule Worn Pads sensor Sensor „Beläge verschlissen“ MCCB OR Switch MCCB ODER Schalter 1 OR 2 brakes series connected AUSGANG GLEICHSTROM (V1 + V2) < Max Output voltage (V1 + V2) < max. Ausgangsspannung Brake Interface Bremsenschnittstelle Bremsenstatus Mikroschalter öffnen / schließen (Bremse aktivieren) Befehl „Öffnen“ / "Schließen" Brake Status Open/Close Micro-switch (Brake Enable) Open/Close...

Open the catalog to page 7
Power Supply V317 for electromagnetic brakes : english / german - 8

POWER SUPPLY ENERGIEVERSORGUNG OUTPUT DC CURRENT MODE WITH MAGNETIC LOSS COMPENSATION AUSGANGSGLEICHSTROM-MODUS MIT MAGNETVERLUSTAUSGLEICH OUTPUT DC CURRENT MODE With magnetic losses compensation MODUS DC-AUSGANG mit Magnetverlustausgleich Adjustable Call Current Time Aufrufstromzeit einstellbar VULKAN DRIVE TECH Economy Current Sparstrom Limit of Call Current Pick Begrenzung Aufrufstromspitze Call Current Aufrufstrom Brake Coil Current Strom Bremsenspule Brake Opening Öffnen der Bremse Control of Economy Current Steuerung Sparstrom Brake Closing Schließen der Bremse Power Supply V317 for...

Open the catalog to page 8
Power Supply V317 for electromagnetic brakes : english / german - 9

POWER SUPPLY ENERGIEVERSORGUNG FEATURES EIGENSCHAFTEN Power Supply Versorgungsspannung Frequency Frequenz Maximum Output Voltage Maximale Ausgangsspannung Output Current Ausgangsstrom ON-OFF Duty Cycle AN / AUS-Zyklen pro Std. Environmental Temperature Range Umgebungstemperaturbereich Weight (with IP65 protection level cabinet) Gewicht (mit IP65-Schrank) DC Output Mode Ausgangsstrom DC Voltage – Open Loop / DC Current – Close Loop / Gleichspannung – Kreis öffnen / Gleichspannung – Kreis schließen Electrical Features Elektrische Merkmale Configurable according to Brake Model / Konfigurierbar...

Open the catalog to page 9
Power Supply V317 for electromagnetic brakes : english / german - 10

VALIDITY CLAUSE GÜLTIGKEITSKLAUSEL VALIDITY CLAUSE The present catalogue shall replace all previous editions, any previous printings shall no longer be valid. Based on new developments, VULKAN Kupplungs- und Getriebebau Bernhard Hackforth GmbH & Co. KG (hereinafter called “VULKAN”) reserves the right to amend and change any details contained in this catalogue. The new data shall only apply with respect to brakes that were ordered after said amendment or change. It shall be the responsibility of the user to ensure that only the latest catalogue issue will be used. The latest issue can be...

Open the catalog to page 10
Power Supply V317 for electromagnetic brakes : english / german - 12

PUBLISHER: Division: VULKAN Drive Tech Head Office: VULKAN Kupplungs- und Getriebebau Bernhard Hackforth GmbH & Co. KG Heerstraße 66, 44653 Herne / Germany Phone: + 49 (23 25) 922-0 Fax: + 49 (23 25) 71110 E-mail: info.vdt@vulkan.com CONCEPT AND DESIGN: Hackforth Holding GmbH & Co. KG VULKAN Marketing Heerstraße 66, 44653 Herne / Germany E-mail: marketing@vulkan.com STATUS: 05/2019 All duplication, reprinting and translation rights are reserved. Further remarks for the VULKAN Kupplungs- und Getriebebau Bernhard Hackforth GmbH & Co. KG assembly are available on request.

Open the catalog to page 12

All VULKAN Industry and Energy catalogs and technical brochures

  1. E.O.T. CRANES

    30 Pages

Archived catalogs

  1. Vulkardan E

    16 Pages

  2. Rato S

    28 Pages

  3. Rato R

    16 Pages

  4. Vulastik L

    20 Pages

  5. Vulkardan L&P

    20 Pages

  6. Rato DS

    16 Pages