video corpo

Solutions for Generator Sets
24Pages

{{requestButtons}}

Catalog excerpts

Solutions for Generator Sets - 1

SOLUTIONS FOR GENERATOR SETS

Open the catalog to page 1
Solutions for Generator Sets - 2

Cover image Lufussa: Engines inside of power plant Pavana II.

Open the catalog to page 2
Solutions for Generator Sets - 4

Whether big or small – we serve them all. VULKAN couplings are found not only in main and auxiliary ship drives, PTOs, PTIs and boat drives, but also in stationary power plants used for permanent, temporary or emergency power supply. Generator couplings from VULKAN have always been the first choice for highly flexible coupling of diesel motors with generators. Capacity utilisation in terms of performance and duty cycle is usually high in stationary diesel power plants and CHPs, so the couplings also need to be extremely reliable and offer a long service life. Container and emergency...

Open the catalog to page 4
Solutions for Generator Sets - 5

where failure of the grid would have grave consequences, for example in hospitals, chemical plants, server rooms and, last but not least, in nuclear power stations where the generators would ensure decay heat is removed in the event of disconnection or failure of the power grid. PAGE 6/7 PASSENGER VESSEL Passenger ship Coastal ferry RoPax PAGE 10/11 FPSO/FSRU Floating, production, storage, offloading Floating production regasification unit PAGE 6/7 OFFSHORE SUPPORT VESSEL Platform supply vessel Anchor handling tug supply Wind farm service vessel PAGE 8/9 DRILLING VESSEL Jack-up...

Open the catalog to page 5
Solutions for Generator Sets - 6

Solutions for Generator Sets

Open the catalog to page 6
Solutions for Generator Sets - 7

PORT CARGO OIL REFINERY BUILDINGS/HANDLING FACILITIES The increasing difference in sizes of ports reflects changes in ship operations and the effort to fully realize economies of scale to reduce transportation costs. The port turnaround time represents competitiveness between maritime ports. Nowadays onshore power supply for vessels at berth results in a significantly lower emission levels of sulfur dioxide and nitric oxide. Petroleum demand for emerging economies is increasing rapidly due to an increasing consumer demand for petroleum products. VULKAN meets the requirements of...

Open the catalog to page 7
Solutions for Generator Sets - 8

Solutions for Generator Sets

Open the catalog to page 8
Solutions for Generator Sets - 9

Under the term offshore support vessels diverse types of vessel can be found, starting with seismic survey ships, Platform Supply Vessels (PSV), Anchor Handling Tug Supply vessels (AHTS), Remotely Operated Vehicle (ROV) support vessels, dive support vessels and a variety of combinations of these. These vessels, especially with diesel-electric propulsion systems demand the highest level of total reliability with continuous operation. Passenger vessels are characterized in particular by comfort-based conventional diesel mechanic or diesel electric propulsion concepts. The onboard generator...

Open the catalog to page 9
Solutions for Generator Sets - 10

Solutions for Generator Sets

Open the catalog to page 10
Solutions for Generator Sets - 11

DATA CENTER CARGO VESSEL DRILLING VESSEL Digitalization to improve business processes is a current major global trend. A data center is a centralized repository, which may be physical or virtual, that houses computer systems for management, storage, and dissemination of information and data organized around a business entity. These massive facilities consume an unthinkable amount of energy to power such extensive servers. VULKAN in the generator set package plays an important role to guarantee continuous power supply. Mega-intercontinental cargo vessels such as container vessels, bulk...

Open the catalog to page 11
Solutions for Generator Sets - 12

Solutions for Generator Sets

Open the catalog to page 12
Solutions for Generator Sets - 13

FLOATING STATIONARY FPSO/FSRUPOWER PLANT POWER PLANT The idea of floating power plants is an ideal solution for power production on an interim basis. These floating power plants can be relocated and connected to the grid to support local power shortages where and when needed. VULKAN provides customized solutions for the generator set packages onboard with consideration for the varying requirements demanded by this application. The design set-up of stationary power plants is commonly based on ISO 8528-1 standard with different modes of operation with continuous and limited time...

Open the catalog to page 13
Solutions for Generator Sets - 14

Safety in system operation with certified quality. We see ourselves as part of our customers‘ quality chain and embrace our part of the responsibility for their success. Here we can set and achieve high goals. The quality of our products and services reflects the strength and tradition of the VULKAN Group: We tap into our experience as market leaders in the area of highly sophisticated marine propulsion technology, where highest quality standards in certification and acceptance processes are ensured by international classification societies, and use it for projects in industrial fields of...

Open the catalog to page 14
Solutions for Generator Sets - 15

The International Association of Classification Societies (IACS) is a technically based non-governmental organization that currently consists of twelve member marine classification societies. Marine classification is a system for promoting the safety of life, property and the environment primarily through the establishment and verification of compliance with technical and engineering standards for the design, construction and life-cycle maintenance of ships, offshore units and other marine-related facilities. These standards are contained in rules established by each Society. IACS provides...

Open the catalog to page 15
Solutions for Generator Sets - 16

Understanding ISO 8528-1 generator set rating. Generator set ratings guidelines are designed to size the generator set to meet the load requirements of an application. The four types of generator set ratings are standby, prime power, limited running time, and base load (continuous power). Consider building expansion and future load additions when determining generator set loads. The average power required of a generator set is a calculated value, as shown in the following paragraphs. The life expectancy—mean time between overhauls (MTBO)—and performance of generator sets are contingent upon...

Open the catalog to page 16
Solutions for Generator Sets - 17

the load on an engine increases the time between overhauls. Follow the ratings guidelines to maximize MTBO for generator set engines. The ratings shown in this technical information bulletin are common throughout the industry. Government agencies, military agencies, and other sources may publish their own definitions and ratings guidelines. Before applying other ratings to generator sets, contact a factory repre- sentative for approval. Generator set ratings are similar between generator set manufacturers due to the industry standards as listed in each ratings sections of this bulletin....

Open the catalog to page 17

All VULKAN Marine catalogs and technical brochures

  1. TORVIB

    2 Pages

  2. MDS 2