Industrial Monitoring System Viet Technology And Investment Corporation JSC., 41B Ly Thai To, Hoan Kiem Ward, Hanoi City, Vietnam
Open the catalog to page 1COMPANY INTRODUCTION Established in 2017 with the vision of becoming a leading investment and technology integration group in Vietnam, VIET TECHNOLOGY AND INVESTMENT CORPORATION JSC., (VTI) has increasingly earned the trust of clients and partners by being entrusted with the implementation of large-scale and highly complex projects, both in terms of management capabilities andtechnical expertise. VTI's core products are researched and developed to serve various sectors, including: Energy Efficiency Power Grid Safety Corridor FOCUSING ON A COMPREHENSIVE ECOSYSTERM OF DIVERSE MONITERING SOLUTIONS...
Open the catalog to page 2MONITERING SYSTERM BACKGROUND In the current context of digital transformation closely tied to green energy, the importance of energy monitoring solutions cannot be underestimated. As businesses and organizations increasingly rely on complex IT ecosystems to drive operational performance, the need for real-time monitoring and incident management has become critically important. The Monitoring System acts as a vigilant steward of digital infrastructure, providing continuous visibility into network performance, equipment status, server operations, and information security.
Open the catalog to page 3MANUAL PROCESS > Data entry errors, lack of comprehensive monitoring, causing confusion. > Inaccurate evaluations degrade the quality of the monitoring process > Difficulties in scaling effectively, requiring more human resources and assets. > Hinders the system's ability to adapt to changing requirements. > Limited real-time awareness, insufficient information, and misjudgment of the situation. > Reduces the flexibility of the decision- making process
Open the catalog to page 4DATA COLLECTION/PROCESSING ANALYSIS/INTERGRATION MANAGEMENT Monitoring data collection and processing include: > Quickest response to potential incidents. > Optimize equipment maintenance and repair capabilities. > Reduce production downtime. > Remote, centralized management. > Trend charts, statistics, and reports.
Open the catalog to page 5Diagram of the Internet-Connected Monitoring Solution Architecture: VTI’S INDUSTRIAL MONITORING SYSTEM • Independent connection using the internet without affecting the internal network of the managing unit. • Security vulnerability scanning and malware removal from the IT system before establishing the connecti
Open the catalog to page 6Diagram of the WAN-Connected Monitoring Solution Architecture: VTI’S INDUSTRIAL MONITORING SYSTEM • Devices within the WAN will inherit the existing security infrastructure. • Devices connecting to the internet will undergo vulnerability scanning and malware remov
Open the catalog to page 7Without the wireless humidity/ temperature monitoring system With the wireless humidity/temperature monitoring system Data Center Profile 5,000 square feet with a combination of servers, storage, and network equipment co-located within the facility - 13% energy savings representing over 300,160 kWh saving annually (~33,000 USD/year) - 22% reclaim of current space - reduce power emissions generation carbon footprint by 174,093 lbs of CO2
Open the catalog to page 8APPLICATION OF IOT MONITORING TECHNOLOGY ENERGY MANAGEMENT SYSTEM AI CAMERA FOR SMOKE, FIRE, AND VIOLATION DETECTION ZONING / ALERTING FOR RESTRICTED OR HAZARDOUS AREAS TEMPERATURE / HUMIDITY MONITORING SYSTEM
Open the catalog to page 9- Monitoring of electrical systems and energy consumption - Optimization of energy usage - Improved management processes: automated reporting, data digitization, energy consumption analysis and evaluation - Aligned with ISO 50001 - the international standard for energy management systems - Reduced manpower required for operation - Lower risk of power outages; enhanced safety and reliability of power supply - Analysis and evaluation of power losses - Support for evaluation, planning, and maintenance of electrical equipment (CBM) DANH SACH TRAM & TINH TRANG
Open the catalog to page 10- All loads, production lines, and office areas are included. The monitoring scale is tailored to customer requirements. - Power quality is measured in real time. - Energy consumption reports can be generated on demand for management. - Incidents and issues are alerted in advance. - Control and optimization of factory systems: air conditioning, drying systems, cooling systems, etc. Outdoor Unit REYQ Concealed Ceiling Unit Wall Mounted Unit FXAQ Branch Selector Unit
Open the catalog to page 11Centralized Management for Distributed Factories - The system can operate normally without geographical limitations. - Unlimited number of measurement points (based on customer requirements). - User-friendly interface. EE Dashboard III Maps sri Electrical equipments 0* Thermal monitoring & BIM viewer A All alarms l±i Reports Tram HOkV H$i Hryp E25.6 Tram 220 kV Thap Cham Tram demo 1 nhiet va thong «yi wan tiarh May bien ap 2 (38/ 6 kV) Ha Giang (Khongchfnh si>a) Test d<? chinh x£c cam bren ^ ^UlONDDA rftUN)G iancha dOncoa PHONG, Kien Thanh Nhtr Quynb Long Hung
Open the catalog to page 122. AI CAMERA FOR SMOKE, FIRE, AND VIOLATION DETECTION Integration of Artificial Intelligence (AI) for Smoke Detection AI is integrated to detect smoke within substations or in cases of fire or smoke outside the station fence, utilizing thermal monitoring cameras or existing cameras installed at the station. Immediate alerts are sent to the control center, facility management, or the central fire protection panel.
Open the catalog to page 133. ZONING / ALERTING FOR RESTRICTED OR HAZARDOUS AREAS Safety Corridor Violation Monitoring System The system utilizes LIDAR technology to define precise protection planes tailored to specific conditions and terrain of each safety zone. These protection planes are automatically established to enclose the safety area, with the distance from the monitoring plane to the safety lane being flexibly configurable. Whenever any object breaches the protection plane, the system immediately triggers an on-site alert through alarms and warning lights to provide early warnings and prevent intrusion into the...